{"id":1770,"date":"2026-07-25T15:55:49","date_gmt":"2026-07-25T07:55:49","guid":{"rendered":"https:\/\/jutrion.com\/?page_id=1770"},"modified":"2026-07-25T16:20:59","modified_gmt":"2026-07-25T08:20:59","slug":"juq5-pc-class-automatic-transfer-switch","status":"publish","type":"page","link":"https:\/\/jutrion.com\/es\/products\/juq5-pc-class-automatic-transfer-switch\/","title":{"rendered":"Interruptor de transferencia autom\u00e1tica de clase PC JUQ5"},"content":{"rendered":"<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-1\">Interruptor de transferencia autom\u00e1tica de clase PC JUQ5<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">El Interruptor de Transferencia Autom\u00e1tica Clase PC de la Serie JUQ5 est\u00e1 dise\u00f1ado para AC 50\/60 Hz, AC 400 V y corriente nominal de hasta 800 A. Transfiere autom\u00e1ticamente la carga entre la fuente de alimentaci\u00f3n normal y la de reserva cuando ocurre una falla de energ\u00eda, subtensi\u00f3n, sobretensi\u00f3n o p\u00e9rdida de fase. El interruptor soporta operaci\u00f3n autom\u00e1tica y manual y cuenta con posiciones I-0-II con enclavamiento fiable.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\"><strong>Est\u00e1ndar: IEC 60947-6-1<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-7b4500cd wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-1169\"><a class=\"wp-block-button__link has-palette-color-9-color has-text-color has-link-color wp-element-button\"><strong>OBTENGA SU COTIZACI\u00d3N<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-1024x768.png\" alt=\"\" class=\"wp-image-1256\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-1024x768.png 1024w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-300x225.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-768x576.png 768w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863.png 1448w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-3\"><strong>Caracter\u00edsticas principales del interruptor de transferencia autom\u00e1tica de clase PC de la serie JUQ5<\/strong><\/h2>\n<\/blockquote>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong>Dise\u00f1o verdadero de clase PC<\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mecanismo de transferencia dedicado para una conmutaci\u00f3n fiable.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Conmutaci\u00f3n de tres posiciones I-O-II<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Posiciones Normal, Apagado y Reserva con enclavamiento mec\u00e1nico.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Operaci\u00f3n autom\u00e1tica y manual<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Admite transferencia autom\u00e1tica y control manual.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Monitoreo de fuentes de alimentaci\u00f3n<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Monitorea las fuentes de alimentaci\u00f3n normal y de reserva.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Amplio rango de corriente<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Disponible desde 16A hasta 800A con opciones de 2P, 3P y 4P.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Larga vida \u00fatil<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Contactos y mecanismo duraderos para una operaci\u00f3n fiable.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-4\"><strong>Descripci\u00f3n general de los componentes del JUQ5<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Explore los componentes principales y los controles de operaci\u00f3n del interruptor de transferencia autom\u00e1tica de clase PC de la serie JUQ5, incluidos los terminales de alimentaci\u00f3n, los indicadores de posici\u00f3n, los terminales de control y las funciones de operaci\u00f3n manual.<\/strong><\/p>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"853\" height=\"569\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure.png\" alt=\"\" class=\"wp-image-1771\" style=\"width:687px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure.png 853w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure-300x200.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure-768x512.png 768w\" sizes=\"auto, (max-width: 853px) 100vw, 853px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-5\"><strong>Especificaciones t\u00e9cnicas<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Par\u00e1metro<\/strong><\/th><th><strong>Especificaci\u00f3n<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Modelo del producto<\/td><td>Interruptor de transferencia autom\u00e1tica de clase PC JUQ5<\/td><\/tr><tr><td>Clase del producto<\/td><td>Clase PC<\/td><\/tr><tr><td>Corriente nominal (In)<\/td><td>16A\u2013800A<\/td><\/tr><tr><td>N\u00famero de polos<\/td><td>2P \/ 3P \/ 4P<\/td><\/tr><tr><td>Tensi\u00f3n operativa nominal (Ue)<\/td><td>AC 230V \/ 400V<\/td><\/tr><tr><td>Frecuencia nominal<\/td><td>50\/60Hz<\/td><\/tr><tr><td>Tensi\u00f3n de aislamiento nominal (Ui)<\/td><td>AC 690V<\/td><\/tr><tr><td>Tensi\u00f3n nominal de resistencia a impulsos (Uimp)<\/td><td>8kV<\/td><\/tr><tr><td>Categor\u00eda de utilizaci\u00f3n<\/td><td>AC-33iB<\/td><\/tr><tr><td>Posiciones de conmutaci\u00f3n<\/td><td>I\u2013O\u2013II<\/td><\/tr><tr><td>Modo de operaci\u00f3n<\/td><td>Autom\u00e1tico \/ Manual<\/td><\/tr><tr><td>Tiempo de transferencia<\/td><td>\u22641,3s<\/td><\/tr><tr><td>Tiempo de transferencia de contacto<\/td><td>\u22640,6s<\/td><\/tr><tr><td>Enclavamiento mec\u00e1nico<\/td><td>S\u00ed<\/td><\/tr><tr><td>Funci\u00f3n de aislamiento<\/td><td>S\u00ed<\/td><\/tr><tr><td>M\u00e9todo de cableado<\/td><td>Conexi\u00f3n frontal<\/td><\/tr><tr><td>M\u00e9todo de montaje<\/td><td>Instalaci\u00f3n vertical fija<\/td><\/tr><tr><td>Grado de protecci\u00f3n<\/td><td>IP20<\/td><\/tr><tr><td>Temperatura ambiente de operaci\u00f3n<\/td><td>-5\u00b0C a +40\u00b0C<\/td><\/tr><tr><td>Altitud<\/td><td>\u22642000m<\/td><\/tr><tr><td>Norma aplicable<\/td><td>IEC 60947-6-1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-6 wp-block-paragraph\"><strong>LAS ESPECIFICACIONES T\u00c9CNICAS PUEDEN VARIAR SEG\u00daN EL TAMA\u00d1O DEL MARCO, LA CONFIGURACI\u00d3N DE POLOS Y EL TIPO DE CONTROLADOR. POR FAVOR, CONTACTE A JUTRION PARA LA SELECCI\u00d3N DETALLADA DEL MODELO.<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-7\"><strong><strong>Corriente Nominal<\/strong><\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Modelo<\/strong><\/th><th><strong>Corriente Nominal<\/strong><\/th><\/tr><\/thead><tbody><tr><td>JUQ5-63<\/td><td>16A, 20A, 25A, 32A, 40A, 50A, 63A<\/td><\/tr><tr><td>JUQ5-80<\/td><td>63A, 80A<\/td><\/tr><tr><td>JUQ5-125<\/td><td>63A, 80A, 100A, 125A<\/td><\/tr><tr><td>JUQ5-225<\/td><td>100A, 125A, 160A, 180A, 200A, 225A<\/td><\/tr><tr><td>JUQ5-250<\/td><td>100A, 125A, 160A, 180A, 200A, 225A, 250A<\/td><\/tr><tr><td>JUQ5-400<\/td><td>250A, 315A, 350A, 400A<\/td><\/tr><tr><td>JUQ5-630<\/td><td>400A, 500A, 630A<\/td><\/tr><tr><td>JUQ5-800<\/td><td>630A, 700A, 800A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-8\"><strong>Aplicaciones<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Edificios comerciales<\/strong><br>Adecuado para edificios de oficinas, centros comerciales, hoteles y otras instalaciones comerciales que requieren una transferencia de energ\u00eda confiable.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Instalaciones industriales<\/strong><br>Dise\u00f1ado para f\u00e1bricas, talleres, l\u00edneas de producci\u00f3n y sistemas de distribuci\u00f3n de energ\u00eda industrial.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Sistemas de respaldo con generador<\/strong><br>Transfiere autom\u00e1ticamente la carga a un generador de respaldo cuando falla el suministro de energ\u00eda normal.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Centros de datos y salas de comunicaci\u00f3n<\/strong><br>Ayuda a mantener energ\u00eda continua para servidores, equipos de red y sistemas de comunicaci\u00f3n.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Hospitales e instalaciones p\u00fablicas<\/strong><br>Adecuado para cargas el\u00e9ctricas importantes donde se requiere continuidad de energ\u00eda y confiabilidad operativa.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Edificios residenciales y de uso mixto<\/strong><br>Ideal para apartamentos, villas, edificios residenciales e instalaciones de uso mixto equipadas con sistemas de energ\u00eda de respaldo.<\/p>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-9\"><strong>Cumplimiento y normas<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">El interruptor de transferencia autom\u00e1tica JUQ5 Clase PC est\u00e1 dise\u00f1ado y fabricado de acuerdo con las normas internacionales relevantes para equipos el\u00e9ctricos de baja tensi\u00f3n, ayudando a garantizar una operaci\u00f3n segura, una transferencia de energ\u00eda confiable y un rendimiento a largo plazo.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>IEC 60947-6-1<\/strong> \u2013 Aparamenta de baja tensi\u00f3n y control \u2013 Equipos de conmutaci\u00f3n de transferencia<\/li>\n\n\n\n<li><strong>IEC 60947-1<\/strong> \u2013 Aparamenta de baja tensi\u00f3n y control \u2013 Reglas generales<\/li>\n\n\n\n<li><strong>IEC 60664<\/strong> \u2013 Coordinaci\u00f3n de aislamiento para equipos dentro de sistemas de baja tensi\u00f3n<\/li>\n\n\n\n<li><strong>Requisitos CE<\/strong> \u2013 Dise\u00f1ado para cumplir con los requisitos europeos aplicables de equipos el\u00e9ctricos de baja tensi\u00f3n<\/li>\n\n\n\n<li><strong>Requisitos RoHS<\/strong> \u2013 Cumple con las restricciones sobre sustancias peligrosas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Los documentos de certificaci\u00f3n y cumplimiento pueden variar seg\u00fan el modelo del producto y los requisitos del pedido. Por favor, contacte a JUTRION para confirmaci\u00f3n.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-10\"><strong>\u00bfPor qu\u00e9 elegir JUTRION JUQ5 ATS?<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-11 is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Mecanismo de transferencia dedicado Clase PC<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>El JUQ5 utiliza un mecanismo de transferencia dedicado Clase PC dise\u00f1ado espec\u00edficamente para conmutar entre dos fuentes de energ\u00eda. No depende de un mecanismo de interruptor autom\u00e1tico para completar la transferencia, lo que lo hace adecuado para sistemas de distribuci\u00f3n de energ\u00eda que requieren una conmutaci\u00f3n de fuente confiable y estable.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Pruebas funcionales antes del env\u00edo<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Cada unidad JUQ5 se somete a inspecciones de operaci\u00f3n mec\u00e1nica, funci\u00f3n de transferencia y rendimiento el\u00e9ctrico b\u00e1sico antes del env\u00edo para ayudar a reducir el riesgo de problemas de instalaci\u00f3n y operaci\u00f3n.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Servicios flexibles OEM y ODM<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>La marca personalizada, las placas de identificaci\u00f3n del producto, el embalaje, las etiquetas, los manuales y las configuraciones de control seleccionadas est\u00e1n disponibles para distribuidores, fabricantes de tableros y clientes OEM.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Soporte para la Selecci\u00f3n de Ingenier\u00eda<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">JUTRION puede asistir a los clientes en la selecci\u00f3n del ATS adecuado seg\u00fan el voltaje del sistema, corriente nominal, n\u00famero de polos, fuente de alimentaci\u00f3n de reserva y requisitos de aplicaci\u00f3n.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Documentaci\u00f3n T\u00e9cnica Completa<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Hojas de datos del producto, planos dimensionales, instrucciones de instalaci\u00f3n, im\u00e1genes del producto y otros materiales t\u00e9cnicos est\u00e1n disponibles para apoyar el dise\u00f1o del proyecto, la instalaci\u00f3n y la promoci\u00f3n del producto.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Suministro Estable a Gran Escala<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Con un rango de corriente nominal de 16A a 800A, la serie JUQ5 es adecuada para proyectos de distribuci\u00f3n, integraci\u00f3n de equipos y requisitos de compra a gran escala.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-12\"><strong>Preguntas Frecuentes<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfQu\u00e9 es un Interruptor de Transferencia Autom\u00e1tica Clase PC?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Un Interruptor de Transferencia Autom\u00e1tica (ATS) Clase PC es un dispositivo de conmutaci\u00f3n dise\u00f1ado espec\u00edficamente para transferir cargas el\u00e9ctricas entre la fuente de alimentaci\u00f3n normal y la fuente de alimentaci\u00f3n de emergencia. Est\u00e1 destinado a una transferencia fiable de energ\u00eda y no proporciona protecci\u00f3n contra sobrecargas o cortocircuitos. Se deben instalar interruptores autom\u00e1ticos o fusibles adecuados aguas arriba para la protecci\u00f3n del sistema.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfC\u00f3mo elegir la corriente nominal correcta del ATS?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">La corriente asignada del ATS debe ser igual o mayor que la corriente m\u00e1xima de operaci\u00f3n de la carga conectada. Tambi\u00e9n se deben considerar el tipo de carga, la corriente de arranque del motor, la temperatura ambiente y la futura expansi\u00f3n de capacidad para garantizar una operaci\u00f3n segura y fiable.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfPuede el ATS JUQ5 funcionar con un generador di\u00e9sel?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">S\u00ed. El Interruptor de Transferencia Autom\u00e1tica Clase PC JUQ5 es adecuado para aplicaciones que requieren transferencia autom\u00e1tica entre la red el\u00e9ctrica y un generador di\u00e9sel. Se utiliza ampliamente en edificios comerciales, instalaciones industriales, hospitales, centros de datos y otros sistemas de alimentaci\u00f3n de emergencia.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfCu\u00e1l es la diferencia entre un ATS Clase PC y un ATS Clase CB?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Un ATS Clase PC utiliza un mecanismo de conmutaci\u00f3n dedicado dise\u00f1ado espec\u00edficamente para transferir energ\u00eda entre dos fuentes, mientras que un ATS Clase CB generalmente est\u00e1 construido con interruptores autom\u00e1ticos y tambi\u00e9n puede proporcionar protecci\u00f3n contra sobrecarga y cortocircuito. Las unidades ATS Clase PC son generalmente m\u00e1s compactas y optimizadas para una transferencia de energ\u00eda confiable.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfJUTRION ofrece servicios OEM y ODM?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">S\u00ed. JUTRION ofrece servicios OEM y ODM flexibles, incluyendo personalizaci\u00f3n de marca, etiquetas de producto, embalajes, manuales de usuario, documentaci\u00f3n t\u00e9cnica y otras soluciones a medida para satisfacer las necesidades de distribuidores, fabricantes de cuadros el\u00e9ctricos, fabricantes OEM y clientes de proyectos en todo el mundo.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfPor qu\u00e9 elegir JUTRION como su proveedor de ATS?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">JUTRION se especializa en productos el\u00e9ctricos de baja tensi\u00f3n para mercados globales. Estamos comprometidos a proporcionar calidad de producto fiable, soporte t\u00e9cnico profesional, personalizaci\u00f3n flexible, capacidad de producci\u00f3n estable y servicio al cliente \u00e1gil para ayudar a los clientes a construir sistemas de distribuci\u00f3n el\u00e9ctrica seguros y fiables.<\/p>\n\n\n\n<div class=\"wp-block-group alignfull has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-13 is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>HABLE CON NUESTROS ESPECIALISTAS EN ATS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Simplemente ind\u00edquenos su corriente nominal, tensi\u00f3n del sistema, configuraci\u00f3n de polos, fuente de alimentaci\u00f3n de reserva y requisitos de aplicaci\u00f3n. Nuestros ingenieros recomendar\u00e1n el Interruptor de Transferencia Autom\u00e1tica JUQ5 PC Class m\u00e1s adecuado para su proyecto.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 popmake-1169\"><a class=\"wp-block-button__link wp-element-button\"><strong>Contacte a JUTRION Hoy<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>JUQ5 PC Class Automatic Transfer Switch The JUQ5 Series PC Class Automatic Transfer Switch is designed for AC 50\/60 Hz, AC 400 V, and rated current up to 800 A. It automatically transfers the load between the normal and standby power sources when a power failure, undervoltage, overvoltage, or phase loss occurs. The switch supports [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":735,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1770","page","type-page","status-publish","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages\/1770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/comments?post=1770"}],"version-history":[{"count":2,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages\/1770\/revisions"}],"predecessor-version":[{"id":2004,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages\/1770\/revisions\/2004"}],"up":[{"embeddable":true,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages\/735"}],"wp:attachment":[{"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/media?parent=1770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}