{"id":1773,"date":"2026-08-28T17:11:23","date_gmt":"2026-08-28T09:11:23","guid":{"rendered":"https:\/\/jutrion.com\/?page_id=1773"},"modified":"2026-08-28T17:11:57","modified_gmt":"2026-08-28T09:11:57","slug":"juq1-pc-class-automatic-transfer-switch","status":"publish","type":"page","link":"https:\/\/jutrion.com\/es\/products\/juq1-pc-class-automatic-transfer-switch\/","title":{"rendered":"Interruptor de transferencia autom\u00e1tica Clase PC JUQ1"},"content":{"rendered":"<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-1\">Interruptor de transferencia autom\u00e1tica Clase PC JUQ1<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">La Serie JUQ1 es un Conmutador de Transferencia Autom\u00e1tica de Clase PC tipo aislamiento dise\u00f1ado para sistemas de distribuci\u00f3n de doble alimentaci\u00f3n de alta capacidad. Con corrientes nominales de 16A a 3200A y posiciones de conmutaci\u00f3n estables I-O-II, combina la transferencia de potencia y el aislamiento de carga en una unidad integrada.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\"><strong>Est\u00e1ndar: IEC 60947-6-1<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-7b4500cd wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-1169\"><a class=\"wp-block-button__link has-palette-color-9-color has-text-color has-link-color wp-element-button\"><strong>OBTENGA SU COTIZACI\u00d3N<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-1024x768.png\" alt=\"\" class=\"wp-image-1258\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-1024x768.png 1024w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-300x225.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-768x576.png 768w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815.png 1448w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-3\"><strong><strong>Caracter\u00edsticas Principales del Conmutador de Transferencia Autom\u00e1tica JUQ1<\/strong><\/strong><\/h2>\n<\/blockquote>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Estructura de Conmutaci\u00f3n Tipo Aislamiento<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Combina funciones de transferencia autom\u00e1tica de potencia y aislamiento de carga en una unidad de conmutaci\u00f3n integrada.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Rango de Corriente de 16A\u20133200A<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cubre una amplia gama de capacidades de distribuci\u00f3n, desde tableros de conmutaci\u00f3n est\u00e1ndar hasta grandes sistemas de potencia industriales.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Posiciones Estables I-O-II<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Proporciona posiciones de alimentaci\u00f3n normal, OFF y alimentaci\u00f3n de respaldo para una conmutaci\u00f3n confiable y aislamiento visible del circuito.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>M\u00faltiples Modos de Operaci\u00f3n<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Soporta operaci\u00f3n autom\u00e1tica, control el\u00e9ctrico remoto, operaci\u00f3n manual de emergencia y conmutaci\u00f3n manual.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong><strong>Enclavamiento Mec\u00e1nico y El\u00e9ctrico<\/strong><\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los mecanismos de enclavamiento independientes evitan que las fuentes de alimentaci\u00f3n normal y de respaldo se conecten simult\u00e1neamente.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong><strong>Opciones de 3 Polos y 4 Polos<\/strong><\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Disponible en configuraciones 3P y 4P para diferentes sistemas de distribuci\u00f3n de baja tensi\u00f3n.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-4\"><strong>Descripci\u00f3n General de Componentes del JUQ1<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Explore los componentes principales y controles de operaci\u00f3n del Conmutador de Transferencia Autom\u00e1tica de Clase PC JUQ1, incluyendo terminales de potencia, indicadores de posici\u00f3n de fuente, terminales de control, cerradura el\u00e9ctrica y funciones de operaci\u00f3n manual de emergencia.<\/strong><\/p>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"943\" height=\"550\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5.png\" alt=\"\" class=\"wp-image-2005\" style=\"aspect-ratio:1.7145809772647507;width:1300px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5.png 943w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5-300x175.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5-768x448.png 768w\" sizes=\"auto, (max-width: 943px) 100vw, 943px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-5\"><strong>Especificaciones t\u00e9cnicas<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Par\u00e1metro<\/th><th>Especificaciones del JUQ1<\/th><\/tr><\/thead><tbody><tr><td>Tipo de Producto<\/td><td>Interruptor de transferencia autom\u00e1tica Clase PC JUQ1<\/td><\/tr><tr><td>Corriente Nominal<\/td><td>16 A\u20133200 A<\/td><\/tr><tr><td>N\u00famero de polos<\/td><td>3P, 4P<\/td><\/tr><tr><td>Tensi\u00f3n Operacional Nominal<\/td><td>CA 400 V<\/td><\/tr><tr><td>Frecuencia nominal<\/td><td>50 Hz<\/td><\/tr><tr><td>Tensi\u00f3n de Control<\/td><td>AC 220 V est\u00e1ndar; opciones DC 24 V, DC 48 V o DC 110 V<\/td><\/tr><tr><td>Posiciones de conmutaci\u00f3n<\/td><td>I\u20130\u2013II<\/td><\/tr><tr><td>Modos de Operaci\u00f3n<\/td><td>Operaci\u00f3n autom\u00e1tica, remota motorizada y manual de emergencia<\/td><\/tr><tr><td>Modos de Transferencia<\/td><td>Red a red, red a generador, transferencia autom\u00e1tica con retorno autom\u00e1tico<\/td><\/tr><tr><td>Categor\u00eda de utilizaci\u00f3n<\/td><td>AC-31A \/ AC-33A \/ AC-35A, dependiendo de la corriente nominal<\/td><\/tr><tr><td>Tensi\u00f3n Nominal de Resistencia a Impulsos<\/td><td>8 kV o 12 kV, dependiendo del tama\u00f1o del marco<\/td><\/tr><tr><td>Tiempo de transferencia<\/td><td>Aproximadamente 0.45\u20131.2 s, dependiendo del tama\u00f1o del marco<\/td><\/tr><tr><td>Configuraci\u00f3n de Polos<\/td><td>3P \/ 4P<\/td><\/tr><tr><td>Clase ATSE<\/td><td>Clase PC<\/td><\/tr><tr><td>Norma aplicable<\/td><td>IEC 60947-6-1 \/ GB\/T 14048.11<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-6 wp-block-paragraph\"><strong>LAS ESPECIFICACIONES T\u00c9CNICAS VAR\u00cdAN SEG\u00daN EL TAMA\u00d1O DEL MARCO, LA CORRIENTE NOMINAL, LA CONFIGURACI\u00d3N DE POLOS Y EL TIPO DE CONTROL. POR FAVOR CONTACTE A JUTRION PARA CONFIRMAR EL MODELO EXACTO DEL JUQ1 Y LA CONFIGURACI\u00d3N DEL PROYECTO.<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-7\"><strong><strong>Corriente Nominal<\/strong><\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Marco del JUQ1<\/th><th>Corriente Nominal Disponible<\/th><\/tr><\/thead><tbody><tr><td>Marco JUQ1-100<\/td><td>20 A, 32 A, 40 A, 63 A, 80 A, 100 A<\/td><\/tr><tr><td>Marco JUQ1-160<\/td><td>125 A, 160 A<\/td><\/tr><tr><td>Marco JUQ1-250<\/td><td>200 A, 225 A, 250 A<\/td><\/tr><tr><td>Marco JUQ1-400<\/td><td>315 A, 400 A<\/td><\/tr><tr><td>Marco JUQ1-630<\/td><td>500 A, 630 A<\/td><\/tr><tr><td>Marco JUQ1-1000<\/td><td>800A, 1000A<\/td><\/tr><tr><td>Marco JUQ1-1250<\/td><td>1250A<\/td><\/tr><tr><td>Marco JUQ1-1600<\/td><td>1600A<\/td><\/tr><tr><td>Marco JUQ1-2000<\/td><td>2000A<\/td><\/tr><tr><td>Marco JUQ1-2500<\/td><td>2500A<\/td><\/tr><tr><td>Marco JUQ1-3200<\/td><td>3200A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-8\"><strong>Aplicaciones<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Edificios comerciales<\/strong><br>Proporciona transferencia autom\u00e1tica entre suministros de energ\u00eda normal y de reserva para edificios de oficinas, centros comerciales, hoteles y otros sistemas de distribuci\u00f3n comercial.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Instalaciones industriales<\/strong><br>Adecuado para f\u00e1bricas, talleres, l\u00edneas de producci\u00f3n y sistemas de distribuci\u00f3n industrial que requieren transferencia confiable entre dos fuentes de energ\u00eda.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Sistemas de respaldo con generador<\/strong><br>Admite transferencia de red a generador y retorno autom\u00e1tico cuando se restablece el suministro de energ\u00eda normal, seg\u00fan la configuraci\u00f3n del controlador seleccionado.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Centros de datos y salas de comunicaci\u00f3n<\/strong><br>Proporciona funcionalidad de transferencia de fuente para centros de datos, salas de comunicaciones, instalaciones de telecomunicaciones y otras instalaciones que requieren continuidad de energ\u00eda confiable.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Hospitales e instalaciones p\u00fablicas<\/strong><br>Adecuado para hospitales, edificios p\u00fablicos y proyectos de infraestructura donde los sistemas de distribuci\u00f3n esenciales requieren una fuente de energ\u00eda alternativa.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Sistemas de Distribuci\u00f3n Principal<\/strong><br>Disponible en corrientes nominales de hasta 3200A para tableros de distribuci\u00f3n principal y otras aplicaciones de transferencia de energ\u00eda normal y de reserva de alta corriente.<\/p>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-9\"><strong>Cumplimiento y normas<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">El Interruptor de Transferencia Autom\u00e1tica Clase PC JUQ1 est\u00e1 dise\u00f1ado para aplicaciones de transferencia de energ\u00eda normal y de reserva de baja tensi\u00f3n. El dise\u00f1o de su producto hace referencia a los requisitos aplicables para equipos de transferencia de conmutaci\u00f3n, aparamenta de baja tensi\u00f3n e interruptores-seccionadores.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>IEC 60947-6-1<\/strong> \u2013 Aparamenta de baja tensi\u00f3n y control \u2013 Equipos de conmutaci\u00f3n de transferencia<\/li>\n\n\n\n<li><strong>IEC 60947-1<\/strong> \u2013 Aparamenta de baja tensi\u00f3n y control \u2013 Reglas generales<\/li>\n\n\n\n<li><strong>IEC 60664<\/strong> \u2013 Coordinaci\u00f3n de aislamiento para equipos dentro de sistemas de baja tensi\u00f3n<\/li>\n\n\n\n<li><strong>Requisitos CE<\/strong> \u2013 Dise\u00f1ado para cumplir con los requisitos europeos aplicables de equipos el\u00e9ctricos de baja tensi\u00f3n<\/li>\n\n\n\n<li><strong>Requisitos RoHS<\/strong> \u2013 Cumple con las restricciones sobre sustancias peligrosas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Las normas aplicables, los documentos de prueba y la informaci\u00f3n de cumplimiento pueden variar seg\u00fan el modelo, la corriente nominal y el mercado de destino. Confirme la documentaci\u00f3n requerida con JUTRION antes de realizar el pedido.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-10\"><strong>\u00bfPor Qu\u00e9 Elegir el ATS JUQ1 de JUTRION?<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-11 is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Mecanismo de transferencia dedicado Clase PC<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>El JUQ1 utiliza un mecanismo de transferencia Clase PC tipo interruptor de carga dise\u00f1ado para conmutar entre fuentes de energ\u00eda normal y de reserva. No depende de dos interruptores autom\u00e1ticos para completar la funci\u00f3n de transferencia.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Controlador L\u00f3gico Integrado<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">El mecanismo de conmutaci\u00f3n y el control l\u00f3gico est\u00e1n integrados en una sola unidad. El controlador proporciona detecci\u00f3n de fuente, comandos de transferencia y transferencia autom\u00e1tica con retorno autom\u00e1tico, seg\u00fan la configuraci\u00f3n seleccionada.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Amplio rango de corriente<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>La serie JUQ1 cubre corrientes nominales de 20A a 3200A, con m\u00faltiples tama\u00f1os de marco para aplicaciones comerciales, industriales y de distribuci\u00f3n principal.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>M\u00faltiples Modos de Operaci\u00f3n<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Admite operaci\u00f3n autom\u00e1tica, operaci\u00f3n remota motorizada y operaci\u00f3n manual de emergencia, lo que permite que el interruptor de transferencia se opere bajo diferentes condiciones de control y mantenimiento.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Enclavamiento El\u00e9ctrico y Mec\u00e1nico<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">El enclavamiento el\u00e9ctrico y mec\u00e1nico ayuda a evitar que las fuentes de energ\u00eda normal y de reserva se conecten simult\u00e1neamente durante la secuencia de transferencia.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Opciones de Configuraci\u00f3n Flexible<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Disponible en configuraciones de 3 polos y 4 polos, con control AC 220V como est\u00e1ndar y opciones de control DC 24V, 48V o 110V seleccionadas.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-12\"><strong>Preguntas Frecuentes<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfQu\u00e9 Es el Interruptor de Transferencia Autom\u00e1tica Clase PC JUQ1?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">El JUQ1 es un interruptor de transferencia autom\u00e1tica Clase PC dise\u00f1ado para transferir una carga entre fuentes de energ\u00eda normal y de reserva. Utiliza un mecanismo de transferencia de interruptor de carga dedicado con control l\u00f3gico integrado. Como ATSE Clase PC, normalmente no proporciona protecci\u00f3n contra sobrecarga o cortocircuito, por lo que se requieren dispositivos de protecci\u00f3n coordinados en el sistema de energ\u00eda.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfC\u00f3mo Elijo la Corriente Nominal Correcta del JUQ1?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Seleccione una corriente nominal del JUQ1 que pueda soportar la corriente m\u00e1s alta esperada a trav\u00e9s del interruptor de transferencia. Tambi\u00e9n verifique la categor\u00eda de utilizaci\u00f3n, el tipo de carga, la corriente de irrupci\u00f3n del motor o transformador, la temperatura ambiente, las condiciones del gabinete, la capacidad de los terminales y la coordinaci\u00f3n con los dispositivos de protecci\u00f3n. La corriente seleccionada debe coincidir con el tama\u00f1o de marco exacto y la funci\u00f3n del proyecto.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfPuede el ATS JUQ1 Funcionar con un Generador Di\u00e9sel?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">S\u00ed. El JUQ1 admite aplicaciones de transferencia de red a generador y retorno autom\u00e1tico cuando se restablece el suministro normal, seg\u00fan el controlador seleccionado y la configuraci\u00f3n del cableado. Confirme la se\u00f1al de arranque del generador, la detecci\u00f3n de voltaje y frecuencia, los retardos de transferencia y la disposici\u00f3n de la energ\u00eda de control antes de realizar el pedido.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfCu\u00e1l Es la Diferencia Entre un ATS Clase PC y un ATS Clase CB?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Un ATS Clase PC utiliza un mecanismo de conmutaci\u00f3n dedicado dise\u00f1ado espec\u00edficamente para transferir energ\u00eda entre dos fuentes, mientras que un ATS Clase CB generalmente est\u00e1 construido con interruptores autom\u00e1ticos y tambi\u00e9n puede proporcionar protecci\u00f3n contra sobrecarga y cortocircuito. Las unidades ATS Clase PC son generalmente m\u00e1s compactas y optimizadas para una transferencia de energ\u00eda confiable.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfDebo Elegir un ATS JUQ1 de 3 Polos o 4 Polos?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Un modelo de 3 polos conmuta los tres conductores de fase mientras deja el neutro sin conmutar. Un modelo de 4 polos tambi\u00e9n conmuta el neutro. La decisi\u00f3n depende de la disposici\u00f3n de puesta a tierra del sistema, la conexi\u00f3n del neutro del generador, si la fuente alternativa se deriva por separado y las reglas de instalaci\u00f3n aplicables.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00bfQu\u00e9 Opciones de Operaci\u00f3n y Control Est\u00e1n Disponibles?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">El JUQ1 admite operaci\u00f3n autom\u00e1tica, operaci\u00f3n remota motorizada y operaci\u00f3n manual de emergencia. El control AC 220V es est\u00e1ndar, mientras que las configuraciones seleccionadas pueden admitir DC 24V, DC 48V o DC 110V. Confirme el tipo de control, la configuraci\u00f3n de polos, la corriente nominal y el modo de transferencia requerido al realizar el pedido.<\/p>\n\n\n\n<div class=\"wp-block-group alignfull has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-13 is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>HABLE CON NUESTROS ESPECIALISTAS EN ATS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Simplemente ind\u00edquenos su corriente nominal, voltaje del sistema, configuraci\u00f3n de polos, fuente de energ\u00eda de reserva y requisitos de aplicaci\u00f3n. Nuestros ingenieros recomendar\u00e1n el Interruptor de Transferencia Autom\u00e1tica Clase PC JUQ1 m\u00e1s adecuado para su proyecto.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 popmake-1169\"><a class=\"wp-block-button__link wp-element-button\"><strong>Contacte a JUTRION Hoy<\/strong><\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>JUQ1 PC Class Automatic Transfer Switch The JUQ1 Series is an isolation-type PC Class Automatic Transfer Switch designed for high-capacity dual-power distribution systems. With rated currents from 16A to 3200A and stable I-O-II switching positions, it combines power transfer and load isolation in one integrated unit. Standard: IEC 60947-6-1 Key Features of the JUQ1 Automatic [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":735,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1773","page","type-page","status-publish","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages\/1773","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/comments?post=1773"}],"version-history":[{"count":3,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages\/1773\/revisions"}],"predecessor-version":[{"id":2006,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages\/1773\/revisions\/2006"}],"up":[{"embeddable":true,"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/pages\/735"}],"wp:attachment":[{"href":"https:\/\/jutrion.com\/es\/wp-json\/wp\/v2\/media?parent=1773"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}