{"id":1770,"date":"2026-07-25T15:55:49","date_gmt":"2026-07-25T07:55:49","guid":{"rendered":"https:\/\/jutrion.com\/?page_id=1770"},"modified":"2026-07-25T16:20:59","modified_gmt":"2026-07-25T08:20:59","slug":"juq5-pc-class-automatic-transfer-switch","status":"publish","type":"page","link":"https:\/\/jutrion.com\/fr\/products\/juq5-pc-class-automatic-transfer-switch\/","title":{"rendered":"JUQ5 Commutateur de transfert automatique de classe PC"},"content":{"rendered":"<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-1\">JUQ5 Commutateur de transfert automatique de classe PC<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">Le Commutateur de Transfert Automatique S\u00e9rie JUQ5 Classe PC est con\u00e7u pour AC 50\/60 Hz, AC 400 V, et un courant nominal jusqu'\u00e0 800 A. Il transf\u00e8re automatiquement la charge entre les sources d'alimentation normale et de secours en cas de coupure de courant, sous-tension, surtension ou perte de phase. Le commutateur supporte les op\u00e9rations automatique et manuelle et dispose de positions I-0-II avec un verrouillage fiable.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\"><strong>Norme : IEC 60947-6-1<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-7b4500cd wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-1169\"><a class=\"wp-block-button__link has-palette-color-9-color has-text-color has-link-color wp-element-button\"><strong>OBTENEZ VOTRE DEVIS<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-1024x768.png\" alt=\"\" class=\"wp-image-1256\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-1024x768.png 1024w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-300x225.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-768x576.png 768w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863.png 1448w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-3\"><strong>Caract\u00e9ristiques principales du commutateur de transfert automatique de classe PC JUQ5<\/strong><\/h2>\n<\/blockquote>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong>V\u00e9ritable conception de classe PC<\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00e9canisme de transfert d\u00e9di\u00e9 pour une commutation fiable.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Commutation \u00e0 trois positions I-O-II<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Positions Normal, Arr\u00eat et Secours avec verrouillage m\u00e9canique.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Fonctionnement automatique et manuel<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prend en charge le transfert automatique et la commande manuelle.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Surveillance de la source d'alimentation<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Surveille les alimentations normale et de secours.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Large plage de courant<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Disponible de 16 A \u00e0 800 A avec options 2P, 3P et 4P.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Longue dur\u00e9e de vie<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Contacts et m\u00e9canisme durables pour un fonctionnement fiable.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-4\"><strong>Aper\u00e7u des composants du JUQ5<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>D\u00e9couvrez les principaux composants et commandes de fonctionnement du commutateur de transfert automatique de classe PC JUQ5, y compris les bornes d'alimentation, les indicateurs de position, les bornes de commande et les fonctions de fonctionnement manuel.<\/strong><\/p>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"853\" height=\"569\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure.png\" alt=\"\" class=\"wp-image-1771\" style=\"width:687px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure.png 853w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure-300x200.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure-768x512.png 768w\" sizes=\"auto, (max-width: 853px) 100vw, 853px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-5\"><strong>Sp\u00e9cifications techniques<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Param\u00e8tre<\/strong><\/th><th><strong>Sp\u00e9cification<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Mod\u00e8le du produit<\/td><td>JUQ5 Commutateur de transfert automatique de classe PC<\/td><\/tr><tr><td>Classe du produit<\/td><td>Classe PC<\/td><\/tr><tr><td>Courant assign\u00e9 (In)<\/td><td>16 A\u2013800 A<\/td><\/tr><tr><td>Nombre de p\u00f4les<\/td><td>2P \/ 3P \/ 4P<\/td><\/tr><tr><td>Tension assign\u00e9e d'emploi (Ue)<\/td><td>AC 230V \/ 400V<\/td><\/tr><tr><td>Fr\u00e9quence assign\u00e9e<\/td><td>50\/60 Hz<\/td><\/tr><tr><td>Tension assign\u00e9e d'isolement (Ui)<\/td><td>AC 690V<\/td><\/tr><tr><td>Tension assign\u00e9e de tenue aux chocs (Uimp)<\/td><td>8 kV<\/td><\/tr><tr><td>Cat\u00e9gorie d'utilisation<\/td><td>AC-33iB<\/td><\/tr><tr><td>Positions de commutation<\/td><td>I\u2013O\u2013II<\/td><\/tr><tr><td>Mode de fonctionnement<\/td><td>Automatique \/ Manuel<\/td><\/tr><tr><td>Temps de transfert<\/td><td>\u22641,3s<\/td><\/tr><tr><td>Temps de transfert des contacts<\/td><td>\u22640,6s<\/td><\/tr><tr><td>Verrouillage m\u00e9canique<\/td><td>Oui<\/td><\/tr><tr><td>Fonction de sectionnement<\/td><td>Oui<\/td><\/tr><tr><td>M\u00e9thode de c\u00e2blage<\/td><td>Raccordement avant<\/td><\/tr><tr><td>M\u00e9thode de montage<\/td><td>Installation verticale fixe<\/td><\/tr><tr><td>Degr\u00e9 de protection<\/td><td>IP20<\/td><\/tr><tr><td>Temp\u00e9rature ambiante de fonctionnement<\/td><td>-5\u00b0C \u00e0 +40\u00b0C<\/td><\/tr><tr><td>Altitude<\/td><td>\u22642000m<\/td><\/tr><tr><td>Norme applicable<\/td><td>IEC 60947-6-1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-6 wp-block-paragraph\"><strong>LES SP\u00c9CIFICATIONS TECHNIQUES PEUVENT VARIER SELON LA TAILLE DU CH\u00c2SSIS, LA CONFIGURATION DES P\u00d4LES ET LE TYPE DE CONTR\u00d4LEUR. VEUILLEZ CONTACTER JUTRION POUR UNE S\u00c9LECTION DE MOD\u00c8LE D\u00c9TAILL\u00c9E.<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-7\"><strong><strong>Courant nominal<\/strong><\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Mod\u00e8le<\/strong><\/th><th><strong>Courant nominal<\/strong><\/th><\/tr><\/thead><tbody><tr><td>JUQ5-63<\/td><td>16A, 20A, 25A, 32A, 40A, 50A, 63A<\/td><\/tr><tr><td>JUQ5-80<\/td><td>63A, 80A<\/td><\/tr><tr><td>JUQ5-125<\/td><td>63A, 80A, 100A, 125A<\/td><\/tr><tr><td>JUQ5-225<\/td><td>100A, 125A, 160A, 180A, 200A, 225A<\/td><\/tr><tr><td>JUQ5-250<\/td><td>100A, 125A, 160A, 180A, 200A, 225A, 250A<\/td><\/tr><tr><td>JUQ5-400<\/td><td>250A, 315A, 350A, 400A<\/td><\/tr><tr><td>JUQ5-630<\/td><td>400A, 500A, 630A<\/td><\/tr><tr><td>JUQ5-800<\/td><td>630A, 700A, 800A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-8\"><strong>Applications<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>B\u00e2timents commerciaux<\/strong><br>Convient aux immeubles de bureaux, centres commerciaux, h\u00f4tels et autres installations commerciales n\u00e9cessitant un transfert de puissance fiable.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Installations industrielles<\/strong><br>Con\u00e7u pour les usines, ateliers, lignes de production et syst\u00e8mes de distribution \u00e9lectrique industrielle.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Syst\u00e8mes de secours par g\u00e9n\u00e9rateur<\/strong><br>Transf\u00e8re automatiquement la charge vers un g\u00e9n\u00e9rateur de secours lorsque l'alimentation normale tombe en panne.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Centres de donn\u00e9es et salles de communication<\/strong><br>Aide \u00e0 maintenir une alimentation continue pour les serveurs, \u00e9quipements r\u00e9seau et syst\u00e8mes de communication.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>H\u00f4pitaux et installations publiques<\/strong><br>Convient aux charges \u00e9lectriques importantes o\u00f9 la continuit\u00e9 de l'alimentation et la fiabilit\u00e9 op\u00e9rationnelle sont requises.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>B\u00e2timents r\u00e9sidentiels et \u00e0 usage mixte<\/strong><br>Id\u00e9al pour les appartements, villas, immeubles r\u00e9sidentiels et installations \u00e0 usage mixte \u00e9quip\u00e9s de syst\u00e8mes d'alimentation de secours.<\/p>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-9\"><strong>Conformit\u00e9 et normes<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Le commutateur de transfert automatique de classe PC JUQ5 est con\u00e7u et fabriqu\u00e9 conform\u00e9ment aux normes internationales pertinentes pour les \u00e9quipements \u00e9lectriques basse tension, contribuant \u00e0 garantir un fonctionnement s\u00fbr, un transfert de puissance fiable et des performances \u00e0 long terme.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>IEC 60947-6-1<\/strong> \u2013 Appareillage \u00e0 basse tension \u2013 \u00c9quipement de commutation de transfert<\/li>\n\n\n\n<li><strong>IEC 60947-1<\/strong> \u2013 Appareillage \u00e0 basse tension \u2013 R\u00e8gles g\u00e9n\u00e9rales<\/li>\n\n\n\n<li><strong>IEC 60664<\/strong> \u2013 Coordination de l'isolement pour les \u00e9quipements dans les syst\u00e8mes basse tension<\/li>\n\n\n\n<li><strong>Exigences CE<\/strong> \u2013 Con\u00e7u pour r\u00e9pondre aux exigences \u00e9lectriques basse tension europ\u00e9ennes applicables<\/li>\n\n\n\n<li><strong>Exigences RoHS<\/strong> \u2013 Conforme aux restrictions sur les substances dangereuses<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les documents de certification et de conformit\u00e9 peuvent varier selon le mod\u00e8le du produit et les exigences de la commande. Veuillez contacter JUTRION pour confirmation.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-10\"><strong>Pourquoi choisir le JUTRION JUQ5 ATS ?<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-11 is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>M\u00e9canisme de transfert d\u00e9di\u00e9 de classe PC<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>Le JUQ5 utilise un m\u00e9canisme de transfert d\u00e9di\u00e9 de classe PC con\u00e7u sp\u00e9cifiquement pour la commutation entre deux sources d'alimentation. Il ne repose pas sur un m\u00e9canisme de disjoncteur pour effectuer le transfert, ce qui le rend adapt\u00e9 aux syst\u00e8mes de distribution \u00e9lectrique n\u00e9cessitant une commutation de source fiable et stable.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Tests fonctionnels avant exp\u00e9dition<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Chaque unit\u00e9 JUQ5 subit des inspections de fonctionnement m\u00e9canique, de fonction de transfert et de performances \u00e9lectriques de base avant exp\u00e9dition afin d'aider \u00e0 r\u00e9duire le risque de probl\u00e8mes d'installation et d'exploitation.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Services OEM et ODM flexibles<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>Une image de marque personnalis\u00e9e, des plaques signal\u00e9tiques de produit, un emballage, des \u00e9tiquettes, des manuels et des configurations de commande s\u00e9lectionn\u00e9es sont disponibles pour les distributeurs, les assembleurs de tableaux et les clients OEM.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Assistance \u00e0 la s\u00e9lection technique<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">JUTRION peut aider les clients \u00e0 s\u00e9lectionner l'ATS appropri\u00e9 en fonction de la tension du syst\u00e8me, du courant nominal, du nombre de p\u00f4les, de la source d'alimentation de secours et des exigences d'application.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Documentation technique compl\u00e8te<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Les fiches techniques produit, les plans cot\u00e9s, les instructions d'installation, les images produit et autres documents techniques sont disponibles pour soutenir la conception de projet, l'installation et la promotion du produit.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Approvisionnement en gros stable<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Avec une plage de courant nominal de 16A \u00e0 800A, la s\u00e9rie JUQ5 convient aux projets de distribution, \u00e0 l'int\u00e9gration d'\u00e9quipements et aux besoins d'achat en gros.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-12\"><strong>Questions fr\u00e9quemment pos\u00e9es<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Qu'est-ce qu'un interrupteur automatique de transfert de classe PC ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Un interrupteur automatique de transfert (ATS) de classe PC est un dispositif de commutation sp\u00e9cialement con\u00e7u pour transf\u00e9rer les charges \u00e9lectriques entre la source d'alimentation normale et la source d'alimentation de secours. Il est destin\u00e9 \u00e0 un transfert d'alimentation fiable et ne fournit pas de protection contre les surcharges ou les courts-circuits. Des disjoncteurs ou fusibles appropri\u00e9s doivent \u00eatre install\u00e9s en amont pour la protection du syst\u00e8me.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Comment choisir le courant nominal correct de l'ATS ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Le courant nominal de l'ATS doit \u00eatre \u00e9gal ou sup\u00e9rieur au courant de fonctionnement maximal de la charge connect\u00e9e. Le type de charge, le courant de d\u00e9marrage du moteur, la temp\u00e9rature ambiante et l'extension future de capacit\u00e9 doivent \u00e9galement \u00eatre pris en compte pour garantir un fonctionnement s\u00fbr et fiable.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>L'ATS JUQ5 peut-il fonctionner avec un g\u00e9n\u00e9rateur diesel ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Oui. L'interrupteur automatique de transfert de classe PC JUQ5 convient aux applications n\u00e9cessitant un transfert automatique entre l'alimentation du r\u00e9seau public et un g\u00e9n\u00e9rateur diesel. Il est largement utilis\u00e9 dans les b\u00e2timents commerciaux, les installations industrielles, les h\u00f4pitaux, les centres de donn\u00e9es et autres syst\u00e8mes d'alimentation de secours.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Quelle est la diff\u00e9rence entre un ATS de classe PC et un ATS de classe CB ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Un ATS de classe PC utilise un m\u00e9canisme de commutation d\u00e9di\u00e9 sp\u00e9cialement con\u00e7u pour transf\u00e9rer l'alimentation entre deux sources, tandis qu'un ATS de classe CB est g\u00e9n\u00e9ralement construit avec des disjoncteurs et peut \u00e9galement fournir une protection contre les surcharges et les courts-circuits. Les unit\u00e9s ATS de classe PC sont g\u00e9n\u00e9ralement plus compactes et optimis\u00e9es pour un transfert d'alimentation fiable.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>JUTRION fournit-il des services OEM et ODM ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Oui. JUTRION fournit des services OEM et ODM flexibles, y compris une image de marque personnalis\u00e9e, des \u00e9tiquettes de produit, un emballage, des manuels d'utilisation, une documentation technique et d'autres solutions sur mesure pour r\u00e9pondre aux besoins des distributeurs, des assembleurs de tableaux, des fabricants OEM et des clients de projets dans le monde entier.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Pourquoi choisir JUTRION comme fournisseur d'ATS ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">JUTRION est sp\u00e9cialis\u00e9 dans les produits \u00e9lectriques basse tension pour les march\u00e9s mondiaux. Nous nous engageons \u00e0 fournir une qualit\u00e9 de produit fiable, un soutien technique professionnel, une personnalisation flexible, une capacit\u00e9 de production stable et un service client r\u00e9actif pour aider les clients \u00e0 construire des syst\u00e8mes de distribution d'\u00e9nergie s\u00fbrs et fiables.<\/p>\n\n\n\n<div class=\"wp-block-group alignfull has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-13 is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>PARLEZ \u00c0 NOS SP\u00c9CIALISTES ATS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Indiquez-nous simplement votre courant nominal, la tension du syst\u00e8me, la configuration des p\u00f4les, la source d'alimentation de secours et les exigences d'application. Nos ing\u00e9nieurs recommanderont l'interrupteur automatique de transfert de classe PC JUQ5 le plus adapt\u00e9 \u00e0 votre projet.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 popmake-1169\"><a class=\"wp-block-button__link wp-element-button\"><strong>Contactez JUTRION aujourd'hui<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>JUQ5 PC Class Automatic Transfer Switch The JUQ5 Series PC Class Automatic Transfer Switch is designed for AC 50\/60 Hz, AC 400 V, and rated current up to 800 A. It automatically transfers the load between the normal and standby power sources when a power failure, undervoltage, overvoltage, or phase loss occurs. The switch supports [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":735,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1770","page","type-page","status-publish","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages\/1770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/comments?post=1770"}],"version-history":[{"count":2,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages\/1770\/revisions"}],"predecessor-version":[{"id":2004,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages\/1770\/revisions\/2004"}],"up":[{"embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages\/735"}],"wp:attachment":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/media?parent=1770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}