{"id":1773,"date":"2026-08-28T17:11:23","date_gmt":"2026-08-28T09:11:23","guid":{"rendered":"https:\/\/jutrion.com\/?page_id=1773"},"modified":"2026-08-28T17:11:57","modified_gmt":"2026-08-28T09:11:57","slug":"juq1-pc-class-automatic-transfer-switch","status":"publish","type":"page","link":"https:\/\/jutrion.com\/fr\/products\/juq1-pc-class-automatic-transfer-switch\/","title":{"rendered":"Interrupteur de transfert automatique de classe PC JUQ1"},"content":{"rendered":"<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-1\">Interrupteur de transfert automatique de classe PC JUQ1<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">La s\u00e9rie JUQ1 est un interrupteur de transfert automatique de classe PC de type isolation con\u00e7u pour les syst\u00e8mes de distribution \u00e0 double alimentation de grande capacit\u00e9. Avec des courants nominaux de 16A \u00e0 3200A et des positions de commutation stables I-O-II, il combine le transfert de puissance et l'isolation de charge en une seule unit\u00e9 int\u00e9gr\u00e9e.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\"><strong>Norme : IEC 60947-6-1<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-7b4500cd wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-1169\"><a class=\"wp-block-button__link has-palette-color-9-color has-text-color has-link-color wp-element-button\"><strong>OBTENEZ VOTRE DEVIS<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-1024x768.png\" alt=\"\" class=\"wp-image-1258\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-1024x768.png 1024w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-300x225.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-768x576.png 768w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815.png 1448w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-3\"><strong><strong>Caract\u00e9ristiques cl\u00e9s de l'interrupteur de transfert automatique JUQ1<\/strong><\/strong><\/h2>\n<\/blockquote>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Structure de commutation de type isolation<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Combine les fonctions de transfert automatique de puissance et d'isolation de charge en une seule unit\u00e9 de commutation int\u00e9gr\u00e9e.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Plage de courant 16A\u20133200A<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Couvre une large gamme de capacit\u00e9s de distribution, des tableaux de commutation standard aux grands syst\u00e8mes d'alimentation industriels.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Positions stables I-O-II<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fournit les positions alimentation normale, OFF et alimentation de secours pour une commutation fiable et une isolation visible du circuit.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Modes de fonctionnement multiples<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prend en charge le fonctionnement automatique, la commande \u00e9lectrique \u00e0 distance, le fonctionnement manuel d'urgence et la commutation manuelle.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong><strong>Verrouillage m\u00e9canique et \u00e9lectrique<\/strong><\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Des m\u00e9canismes de verrouillage ind\u00e9pendants emp\u00eachent les sources d'alimentation normale et de secours d'\u00eatre connect\u00e9es simultan\u00e9ment.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong><strong>Options 3 p\u00f4les et 4 p\u00f4les<\/strong><\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Disponible en configurations 3P et 4P pour diff\u00e9rents syst\u00e8mes de distribution basse tension.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-4\"><strong>Aper\u00e7u des composants JUQ1<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Explorez les principaux composants et commandes de fonctionnement de l'interrupteur de transfert automatique de classe PC JUQ1, y compris les bornes d'alimentation, les indicateurs de position de source, les bornes de commande, le verrou \u00e9lectrique et les fonctions de fonctionnement manuel d'urgence.<\/strong><\/p>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"943\" height=\"550\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5.png\" alt=\"\" class=\"wp-image-2005\" style=\"aspect-ratio:1.7145809772647507;width:1300px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5.png 943w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5-300x175.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5-768x448.png 768w\" sizes=\"auto, (max-width: 943px) 100vw, 943px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-5\"><strong>Sp\u00e9cifications techniques<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Param\u00e8tre<\/th><th>Sp\u00e9cifications JUQ1<\/th><\/tr><\/thead><tbody><tr><td>Type de produit<\/td><td>Interrupteur de transfert automatique de classe PC JUQ1<\/td><\/tr><tr><td>Courant nominal<\/td><td>16 A\u20133200 A<\/td><\/tr><tr><td>Nombre de p\u00f4les<\/td><td>3P, 4P<\/td><\/tr><tr><td>Tension nominale d'emploi<\/td><td>AC 400 V<\/td><\/tr><tr><td>Fr\u00e9quence assign\u00e9e<\/td><td>50 Hz<\/td><\/tr><tr><td>Tension de commande<\/td><td>AC 220 V standard ; options DC 24 V, DC 48 V ou DC 110 V<\/td><\/tr><tr><td>Positions de commutation<\/td><td>I\u20130\u2013II<\/td><\/tr><tr><td>Modes de fonctionnement<\/td><td>Fonctionnement automatique, motoris\u00e9 \u00e0 distance et manuel d'urgence<\/td><\/tr><tr><td>Modes de transfert<\/td><td>R\u00e9seau \u00e0 r\u00e9seau, r\u00e9seau \u00e0 g\u00e9n\u00e9rateur, transfert automatique avec retour automatique<\/td><\/tr><tr><td>Cat\u00e9gorie d'utilisation<\/td><td>AC-31A \/ AC-33A \/ AC-35A, selon le courant nominal<\/td><\/tr><tr><td>Tension nominale de tenue aux chocs<\/td><td>8 kV ou 12 kV, selon la taille du cadre<\/td><\/tr><tr><td>Temps de transfert<\/td><td>Environ 0,45\u20131,2 s, selon la taille du bo\u00eetier<\/td><\/tr><tr><td>Configuration des p\u00f4les<\/td><td>3P \/ 4P<\/td><\/tr><tr><td>Classe ATSE<\/td><td>Classe PC<\/td><\/tr><tr><td>Norme applicable<\/td><td>IEC 60947-6-1 \/ GB\/T 14048.11<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-6 wp-block-paragraph\"><strong>LES SP\u00c9CIFICATIONS TECHNIQUES VARIENT SELON LA TAILLE DU CADRE, LE COURANT NOMINAL, LA CONFIGURATION DES P\u00d4LES ET LE TYPE DE COMMANDE. VEUILLEZ CONTACTER JUTRION POUR CONFIRMER LE MOD\u00c8LE JUQ1 EXACT ET LA CONFIGURATION DU PROJET.<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-7\"><strong><strong>Courant nominal<\/strong><\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Cadre JUQ1<\/th><th>Courant nominal disponible<\/th><\/tr><\/thead><tbody><tr><td>Cadre JUQ1-100<\/td><td>20 A, 32 A, 40 A, 63 A, 80 A, 100 A<\/td><\/tr><tr><td>Cadre JUQ1-160<\/td><td>125 A, 160 A<\/td><\/tr><tr><td>Cadre JUQ1-250<\/td><td>200 A, 225 A, 250 A<\/td><\/tr><tr><td>Cadre JUQ1-400<\/td><td>315 A, 400 A<\/td><\/tr><tr><td>Cadre JUQ1-630<\/td><td>500A, 630A<\/td><\/tr><tr><td>Cadre JUQ1-1000<\/td><td>800A, 1000A<\/td><\/tr><tr><td>Cadre JUQ1-1250<\/td><td>1250A<\/td><\/tr><tr><td>Cadre JUQ1-1600<\/td><td>1600A<\/td><\/tr><tr><td>Cadre JUQ1-2000<\/td><td>2000A<\/td><\/tr><tr><td>Cadre JUQ1-2500<\/td><td>2500A<\/td><\/tr><tr><td>Cadre JUQ1-3200<\/td><td>3200A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-8\"><strong>Applications<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>B\u00e2timents commerciaux<\/strong><br>Assure la commutation automatique entre l'alimentation normale et l'alimentation de secours pour les immeubles de bureaux, les centres commerciaux, les h\u00f4tels et autres syst\u00e8mes de distribution commerciaux.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Installations industrielles<\/strong><br>Convient aux usines, ateliers, lignes de production et syst\u00e8mes de distribution industriels n\u00e9cessitant une commutation fiable entre deux sources d'alimentation.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Syst\u00e8mes de secours par g\u00e9n\u00e9rateur<\/strong><br>Prend en charge la commutation du r\u00e9seau vers le g\u00e9n\u00e9rateur et le retour automatique lorsque l'alimentation normale est r\u00e9tablie, selon la configuration du contr\u00f4leur s\u00e9lectionn\u00e9.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Centres de donn\u00e9es et salles de communication<\/strong><br>Fournit une fonctionnalit\u00e9 de commutation de source pour les centres de donn\u00e9es, les salles de communication, les installations de t\u00e9l\u00e9communications et autres installations n\u00e9cessitant une continuit\u00e9 d'alimentation fiable.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>H\u00f4pitaux et installations publiques<\/strong><br>Convient aux h\u00f4pitaux, b\u00e2timents publics et projets d'infrastructure o\u00f9 les syst\u00e8mes de distribution essentiels n\u00e9cessitent une source d'alimentation alternative.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Syst\u00e8mes de distribution principaux<\/strong><br>Disponible en calibres de courant jusqu'\u00e0 3200A pour les tableaux de distribution principaux et autres applications de commutation d'alimentation normale et de secours \u00e0 courant \u00e9lev\u00e9.<\/p>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-9\"><strong>Conformit\u00e9 et normes<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">L'interrupteur de transfert automatique de classe PC JUQ1 est con\u00e7u pour les applications de commutation d'alimentation normale et de secours basse tension. Sa conception produit fait r\u00e9f\u00e9rence aux exigences applicables pour les \u00e9quipements de commutation de transfert, les appareillages de commutation basse tension et les interrupteurs-sectionneurs.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>IEC 60947-6-1<\/strong> \u2013 Appareillage \u00e0 basse tension \u2013 \u00c9quipement de commutation de transfert<\/li>\n\n\n\n<li><strong>IEC 60947-1<\/strong> \u2013 Appareillage \u00e0 basse tension \u2013 R\u00e8gles g\u00e9n\u00e9rales<\/li>\n\n\n\n<li><strong>IEC 60664<\/strong> \u2013 Coordination de l'isolement pour les \u00e9quipements dans les syst\u00e8mes basse tension<\/li>\n\n\n\n<li><strong>Exigences CE<\/strong> \u2013 Con\u00e7u pour r\u00e9pondre aux exigences \u00e9lectriques basse tension europ\u00e9ennes applicables<\/li>\n\n\n\n<li><strong>Exigences RoHS<\/strong> \u2013 Conforme aux restrictions sur les substances dangereuses<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les normes applicables, les documents d'essai et les informations de conformit\u00e9 peuvent varier selon le mod\u00e8le, le calibre de courant et le march\u00e9 de destination. Veuillez confirmer la documentation requise aupr\u00e8s de JUTRION avant de commander.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-10\"><strong>Pourquoi choisir l'ATS JUQ1 de JUTRION ?<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-11 is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>M\u00e9canisme de transfert d\u00e9di\u00e9 de classe PC<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>Le JUQ1 utilise un m\u00e9canisme de transfert de classe PC de type interrupteur de charge con\u00e7u pour commuter entre les sources d'alimentation normale et de secours. Il ne d\u00e9pend pas de deux disjoncteurs pour accomplir la fonction de transfert.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Contr\u00f4leur logique int\u00e9gr\u00e9<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Le m\u00e9canisme de commutation et le contr\u00f4le logique sont int\u00e9gr\u00e9s dans une seule unit\u00e9. Le contr\u00f4leur assure la d\u00e9tection de source, les commandes de transfert et le transfert automatique avec retour automatique, selon la configuration s\u00e9lectionn\u00e9e.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Large plage de courant<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>La s\u00e9rie JUQ1 couvre des courants nominaux de 20A \u00e0 3200A, avec plusieurs tailles de cadre pour les applications commerciales, industrielles et de distribution principale.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Modes de fonctionnement multiples<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Prend en charge le fonctionnement automatique, le fonctionnement motoris\u00e9 \u00e0 distance et le fonctionnement manuel d'urgence, permettant d'actionner l'interrupteur de transfert dans diff\u00e9rentes conditions de contr\u00f4le et de maintenance.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Verrouillage \u00e9lectrique et m\u00e9canique<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Le verrouillage \u00e9lectrique et m\u00e9canique aide \u00e0 emp\u00eacher les sources d'alimentation normale et de secours d'\u00eatre connect\u00e9es simultan\u00e9ment pendant la s\u00e9quence de transfert.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Options de configuration flexibles<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Disponible en configurations 3 p\u00f4les et 4 p\u00f4les, avec commande AC 220V en standard et options de commande DC 24V, 48V ou 110V s\u00e9lectionn\u00e9es.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-12\"><strong>Questions fr\u00e9quemment pos\u00e9es<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Qu'est-ce que l'interrupteur de transfert automatique de classe PC JUQ1 ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Le JUQ1 est un interrupteur de transfert automatique de classe PC con\u00e7u pour transf\u00e9rer une charge entre les sources d'alimentation normale et de secours. Il utilise un m\u00e9canisme de transfert \u00e0 interrupteur de charge d\u00e9di\u00e9 avec contr\u00f4le logique int\u00e9gr\u00e9. En tant qu'ATSE de classe PC, il ne fournit normalement pas de protection contre les surcharges ou les courts-circuits, de sorte que des dispositifs de protection coordonn\u00e9s sont requis dans le syst\u00e8me d'alimentation.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Comment choisir le calibre de courant JUQ1 correct ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">S\u00e9lectionnez un calibre de courant JUQ1 pouvant supporter le courant le plus \u00e9lev\u00e9 pr\u00e9vu traversant l'interrupteur de transfert. V\u00e9rifiez \u00e9galement la cat\u00e9gorie d'utilisation, le type de charge, le courant d'appel du moteur ou du transformateur, la temp\u00e9rature ambiante, les conditions de l'enceinte, la capacit\u00e9 des bornes et la coordination avec les dispositifs de protection. Le courant s\u00e9lectionn\u00e9 doit correspondre exactement \u00e0 la taille du cadre et au service du projet.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>L'ATS JUQ1 peut-il fonctionner avec un g\u00e9n\u00e9rateur diesel ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Oui. Le JUQ1 prend en charge les applications de commutation du r\u00e9seau vers le g\u00e9n\u00e9rateur et le retour automatique lorsque l'alimentation normale est r\u00e9tablie, selon le contr\u00f4leur s\u00e9lectionn\u00e9 et la configuration du c\u00e2blage. Confirmez le signal de d\u00e9marrage du g\u00e9n\u00e9rateur, la d\u00e9tection de tension et de fr\u00e9quence, les temporisations de transfert et la disposition de l'alimentation de commande avant de commander.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Quelle est la diff\u00e9rence entre un ATS de classe PC et un ATS de classe CB ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Un ATS de classe PC utilise un m\u00e9canisme de commutation d\u00e9di\u00e9 sp\u00e9cialement con\u00e7u pour transf\u00e9rer l'alimentation entre deux sources, tandis qu'un ATS de classe CB est g\u00e9n\u00e9ralement construit avec des disjoncteurs et peut \u00e9galement fournir une protection contre les surcharges et les courts-circuits. Les unit\u00e9s ATS de classe PC sont g\u00e9n\u00e9ralement plus compactes et optimis\u00e9es pour un transfert d'alimentation fiable.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Dois-je choisir un ATS JUQ1 3 p\u00f4les ou 4 p\u00f4les ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Un mod\u00e8le 3 p\u00f4les commute les trois conducteurs de phase tout en laissant le neutre non commut\u00e9. Un mod\u00e8le 4 p\u00f4les commute \u00e9galement le neutre. La d\u00e9cision d\u00e9pend de la configuration de mise \u00e0 la terre du syst\u00e8me, de la connexion du neutre du g\u00e9n\u00e9rateur, du fait que la source alternative soit d\u00e9riv\u00e9e s\u00e9par\u00e9ment et des r\u00e8gles d'installation applicables.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Quelles options de fonctionnement et de contr\u00f4le sont disponibles ?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Le JUQ1 prend en charge le fonctionnement automatique, le fonctionnement motoris\u00e9 \u00e0 distance et le fonctionnement manuel d'urgence. La commande AC 220V est standard, tandis que certaines configurations peuvent prendre en charge DC 24V, DC 48V ou DC 110V. Confirmez le type de commande, la configuration des p\u00f4les, le calibre de courant et le mode de transfert requis lors de la commande.<\/p>\n\n\n\n<div class=\"wp-block-group alignfull has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-13 is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>PARLEZ \u00c0 NOS SP\u00c9CIALISTES ATS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Indiquez-nous simplement votre calibre de courant, la tension du syst\u00e8me, la configuration des p\u00f4les, la source d'alimentation de secours et les exigences d'application. Nos ing\u00e9nieurs recommanderont l'interrupteur de transfert automatique de classe PC JUQ1 le plus adapt\u00e9 \u00e0 votre projet.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 popmake-1169\"><a class=\"wp-block-button__link wp-element-button\"><strong>Contactez JUTRION aujourd'hui<\/strong><\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>JUQ1 PC Class Automatic Transfer Switch The JUQ1 Series is an isolation-type PC Class Automatic Transfer Switch designed for high-capacity dual-power distribution systems. With rated currents from 16A to 3200A and stable I-O-II switching positions, it combines power transfer and load isolation in one integrated unit. Standard: IEC 60947-6-1 Key Features of the JUQ1 Automatic [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":735,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1773","page","type-page","status-publish","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages\/1773","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/comments?post=1773"}],"version-history":[{"count":3,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages\/1773\/revisions"}],"predecessor-version":[{"id":2006,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages\/1773\/revisions\/2006"}],"up":[{"embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/pages\/735"}],"wp:attachment":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/media?parent=1773"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}