{"id":1569,"date":"2026-07-10T12:59:13","date_gmt":"2026-07-10T04:59:13","guid":{"rendered":"https:\/\/jutrion.com\/?p=1569"},"modified":"2026-07-16T22:19:24","modified_gmt":"2026-07-16T14:19:24","slug":"circuit-breaker-accessories-guide","status":"publish","type":"post","link":"https:\/\/jutrion.com\/fr\/circuit-breaker-accessories-guide\/","title":{"rendered":"Le guide ultime des accessoires pour disjoncteurs : types, fonctions et s\u00e9lection"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"443\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-09-22.28.26-1024x443.jpg\" alt=\"\" class=\"wp-image-1570\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-09-22.28.26-1024x443.jpg 1024w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-09-22.28.26-300x130.jpg 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-09-22.28.26-768x333.jpg 768w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-09-22.28.26-1536x665.jpg 1536w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-09-22.28.26.jpg 1760w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-large-font-size wp-elements-1\">R\u00e9ponse rapide : Que sont les accessoires de disjoncteur ?<\/h2>\n<\/blockquote>\n\n\n\n<p class=\"has-palette-color-6-background-color has-background wp-block-paragraph\">Selon <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66277?utm_source.com\" target=\"_blank\" rel=\"noopener\">IEC 60947-2<\/a> (la norme internationale r\u00e9gissant les appareillages basse tension), la fonction principale d\u2019un disjoncteur est de faire, porter et interrompre les courants en conditions normales et anormales sp\u00e9cifi\u00e9es. Cependant, un disjoncteur nu fonctionne comme un interrupteur m\u00e9canique isol\u00e9. Les accessoires de disjoncteur sont des composants auxiliaires modulaires standardis\u00e9s con\u00e7us pour compl\u00e9ter les MCCB, MCB et ACB.<br>Bien qu\u2019ils n\u2019interrompent pas seuls les d\u00e9fauts principaux, ils sont install\u00e9s en interne (comme les contacts auxiliaires et les unit\u00e9s de d\u00e9clenchement) ou en externe (comme les m\u00e9canismes moteurs et les poign\u00e9es rotatives) pour \u00e9tendre les capacit\u00e9s du disjoncteur dans quatre dimensions critiques : protection avanc\u00e9e, commande \u00e0 distance, signalisation d\u2019\u00e9tat et optimisation m\u00e9canique.<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">La valeur strat\u00e9gique : En termes simples, le disjoncteur reste le muscle m\u00e9canique central, mais les accessoires servent de syst\u00e8me nerveux intelligent. Aujourd\u2019hui, d\u00e8s qu\u2019un d\u00e9faut survient, le contact d\u2019alarme transmet instantan\u00e9ment un paquet de t\u00e9l\u00e9m\u00e9trie \u00e0 la salle de contr\u00f4le, tandis que la motorisation permet aux ing\u00e9nieurs d\u2019isoler ou de r\u00e9armer la ligne \u00e0 distance en toute s\u00e9curit\u00e9. Cette int\u00e9gration a r\u00e9duit leur temps moyen de r\u00e9paration (MTTR) de 85 % et a mis l\u2019installation en conformit\u00e9 totale avec les normes modernes d\u2019infrastructure de r\u00e9seau automatis\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-medium-font-size wp-elements-2\">Accessoires courants de disjoncteur<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Nom de l\u2019accessoire<\/td><td>Abr\u00e9viation<\/td><td>Fonction<\/td><\/tr><tr><td>D\u00e9clencheur \u00e0 \u00e9mission<\/td><td>MX<\/td><td>Permet le d\u00e9clenchement \u00e0 distance via un signal \u00e9lectrique.<\/td><\/tr><tr><td>Contact auxiliaire<\/td><td>AX \/ OF<\/td><td>Indique l\u2019\u00e9tat ON \/ OFF du disjoncteur.<\/td><\/tr><tr><td>Contact d\u2019alarme<\/td><td>AL \/ SD<\/td><td>Indique si le disjoncteur s\u2019est d\u00e9clench\u00e9 en raison d\u2019un d\u00e9faut.<\/td><\/tr><tr><td>D\u00e9clencheur \u00e0 minimum de tension<\/td><td>MN \/ UVT<\/td><td>D\u00e9clenche automatiquement le disjoncteur lors des chutes de tension.<\/td><\/tr><tr><td>M\u00e9canisme motoris\u00e9<\/td><td>MOM \/ MO<\/td><td>Permet la fermeture et l\u2019ouverture motoris\u00e9es \u00e0 distance.<\/td><\/tr><tr><td>Raccordement avant<\/td><td>FC<\/td><td>C\u00e2blage standard depuis les bornes avant.<\/td><\/tr><tr><td>Raccordement arri\u00e8re<\/td><td>RC<\/td><td>C\u00e2blage depuis l\u2019arri\u00e8re pour \u00e9conomiser de l\u2019espace dans le tableau.<\/td><\/tr><tr><td>Poign\u00e9e rotative<\/td><td>\u2013<\/td><td>Permet une commutation manuelle plus s\u00fbre \u00e0 l\u2019ext\u00e9rieur de la porte de l\u2019armoire.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-large-font-size wp-elements-3\"><strong>Pourquoi les accessoires de disjoncteur sont-ils importants ?<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les infrastructures industrielles et commerciales modernes, un disjoncteur standard fournit la \u00ab force \u00bb fondamentale \u2014 la capacit\u00e9 m\u00e9canique brute d\u2019interrompre un courant \u00e9lectrique lors d\u2019un d\u00e9faut catastrophique. Cependant, un disjoncteur nu fonctionne comme un composant isol\u00e9. Ce sont les accessoires qui fournissent le \u00ab cerveau \u00bb et le \u00ab syst\u00e8me nerveux \u00bb \u00e0 l\u2019ensemble de l\u2019installation \u00e9lectrique.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00c9quiper vos disjoncteurs des bons accessoires est une n\u00e9cessit\u00e9 op\u00e9rationnelle critique pour plusieurs raisons d\u00e9cisives :<\/li>\n\n\n\n<li>Am\u00e9liorer la s\u00e9curit\u00e9 du personnel sur site : Les environnements \u00e0 haute puissance comportent intrins\u00e8quement des risques d\u2019arc \u00e9lectrique. Des accessoires comme les motorisations et les poign\u00e9es rotatives allong\u00e9es r\u00e9\u00e9crivent compl\u00e8tement vos protocoles de s\u00e9curit\u00e9 sur site en permettant aux op\u00e9rateurs de commuter, r\u00e9armer ou d\u00e9brocher les disjoncteurs \u00e0 distance de s\u00e9curit\u00e9 \u2014 soit \u00e0 l\u2019ext\u00e9rieur d\u2019une porte d\u2019armoire verrouill\u00e9e, soit \u00e0 distance depuis une salle de contr\u00f4le centralis\u00e9e.<\/li>\n\n\n\n<li>Minimiser les arr\u00eats de production co\u00fbteux : Lorsqu\u2019une ligne de production critique s\u2019arr\u00eate soudainement, chaque seconde se traduit par une perte de revenus. Sans accessoires, les \u00e9quipes de maintenance doivent tester manuellement les lignes pour d\u00e9duire <em>pourquoi<\/em> un disjoncteur s\u2019est ouvert. En utilisant des contacts auxiliaires et d\u2019alarme, le disjoncteur transmet instantan\u00e9ment une t\u00e9l\u00e9m\u00e9trie pr\u00e9cise \u00e0 votre syst\u00e8me PLC ou SCADA, diff\u00e9renciant un arr\u00eat manuel de routine d\u2019un d\u00e9clenchement s\u00e9v\u00e8re par court-circuit en quelques millisecondes.<\/li>\n\n\n\n<li>Protection proactive des actifs contre les probl\u00e8mes de qualit\u00e9 de l\u2019alimentation : Alors que les disjoncteurs standard r\u00e9agissent aux surcharges, les machines modernes (comme les centres CNC, les serveurs de donn\u00e9es et les moteurs lourds) sont tr\u00e8s vuln\u00e9rables aux fluctuations de puissance plus subtiles. Les d\u00e9clencheurs \u00e0 minimum de tension (UVR) agissent comme des gardiens proactifs, d\u00e9clenchant le disjoncteur lors de chutes de tension s\u00e9v\u00e8res (creux de tension) avant que la basse tension ne puisse surchauffer et br\u00fbler les enroulements co\u00fbteux des moteurs.<\/li>\n\n\n\n<li>Assurer la conformit\u00e9 internationale et l\u2019optimisation de l\u2019espace\u00a0: les normes internationales telles que IEC 61439 imposent des exigences strictes sur les distances \u00e9lectriques, la s\u00e9paration et la protection contre les ingress (indices IP). Les accessoires structurels, tels que les kits de connexion arri\u00e8re et les \u00e9crans de bornes, permettent aux fabricants d\u2019armoires de g\u00e9rer efficacement les c\u00e2bles massifs, garantissant une conformit\u00e9 totale tout en r\u00e9duisant l\u2019encombrement physique du tableau jusqu\u2019\u00e0 35 %.<\/li>\n<\/ul>\n\n\n\n<p class=\"has-palette-color-4-color has-palette-color-6-background-color has-text-color has-background has-link-color wp-elements-4 wp-block-paragraph\"><strong>En r\u00e9sum\u00e9 : Investir dans des disjoncteurs haut de gamme mais l\u00e9siner sur les accessoires, c\u2019est comme acheter un v\u00e9hicule haute performance sans tableau de bord ni r\u00e9troviseurs. Les accessoires de disjoncteur sont importants car ils transforment la protection \u00e9lectrique brute en continuit\u00e9 op\u00e9rationnelle, en maintenance pr\u00e9visible et en tranquillit\u00e9 d\u2019esprit absolue sur site.<\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-large-font-size wp-elements-5\"><strong>Principaux types d\u2019accessoires de disjoncteur<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Pour construire un r\u00e9seau de distribution basse tension hautement automatis\u00e9 et conforme, les normes industrielles classent les accessoires de disjoncteur en trois cat\u00e9gories fonctionnelles principales selon leur installation physique et leur r\u00f4le op\u00e9rationnel au sein du syst\u00e8me :<\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-6 wp-block-paragraph\"><strong>Ces composants sont install\u00e9s dans des emplacements internes d\u00e9di\u00e9s \u00e0 l\u2019int\u00e9rieur du bo\u00eetier du disjoncteur. Ils s\u2019interfacent directement avec le m\u00e9canisme interne du disjoncteur pour fournir des donn\u00e9es de t\u00e9l\u00e9m\u00e9trie ou ex\u00e9cuter des d\u00e9clenchements de s\u00e9curit\u00e9 automatis\u00e9s.<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"341\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/C4666D43-930C-4222-AF73-4DD1C8D4BE25.png\" alt=\"\" class=\"wp-image-1580\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/C4666D43-930C-4222-AF73-4DD1C8D4BE25.png 800w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/C4666D43-930C-4222-AF73-4DD1C8D4BE25-300x128.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/C4666D43-930C-4222-AF73-4DD1C8D4BE25-768x327.png 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group has-palette-color-6-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\"><strong>D\u00e9clencheurs \u00e0 \u00e9mission (MX \/ SHT) :<\/strong> <\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\">Permettent l\u2019isolement d\u2019urgence \u00e0 distance. Lorsqu\u2019ils sont aliment\u00e9s par une source de tension externe (comme un signal d\u2019alarme incendie ou un bouton d\u2019arr\u00eat d\u2019urgence), le d\u00e9clencheur shunt force instantan\u00e9ment le verrou m\u00e9canique du disjoncteur \u00e0 s\u2019ouvrir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\"><strong><strong>Contacts auxiliaires (AX \/ OF) :<\/strong> <\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\">Agissent comme les \u00ab yeux \u00bb de votre syst\u00e8me d\u2019automatisation. Ils refl\u00e8tent l\u2019\u00e9tat physique des contacts principaux du disjoncteur, envoyant un signal \u00ab Ouvert \u00bb ou \u00ab Ferm\u00e9 \u00bb en temps r\u00e9el aux automates programmables (PLC), syst\u00e8mes SCADA ou voyants sur la porte du tableau.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\"><strong><strong>Contacts d\u2019alarme (AL \/ SD) :<\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\">Il s'agit d'interrupteurs sp\u00e9cialis\u00e9s qui <em>uniquement<\/em> s'actionnent lorsque le disjoncteur se d\u00e9clenche en raison d'un d\u00e9faut \u00e9lectrique (surcharge, court-circuit ou d\u00e9faut \u00e0 la terre). Ils permettent aux \u00e9quipes de maintenance de distinguer imm\u00e9diatement un d\u00e9clenchement dangereux d'un arr\u00eat manuel de routine.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\"><strong><strong><strong>D\u00e9clencheurs \u00e0 minimum de tension (UVR \/ MN) :<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\">D\u00e9clencheurs sous-tension (UVR \/ MN) : gardiens proactifs de la qualit\u00e9 de la tension. Ils d\u00e9clenchent automatiquement le disjoncteur si la tension d\u2019alimentation chute en dessous d\u2019un seuil critique (typiquement entre 35 % et 70 % de la tension nominale), prot\u00e9geant les moteurs en aval contre la destruction lors de creux de tension s\u00e9v\u00e8res.<\/p>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-7 wp-block-paragraph\"><strong>Au-del\u00e0 des composants internes, certains accessoires essentiels sont mont\u00e9s \u00e0 l'ext\u00e9rieur, sur la face avant ou le c\u00f4t\u00e9 du disjoncteur. Ces modules modifient fondamentalement la mani\u00e8re dont l'appareil est actionn\u00e9, faisant passer votre syst\u00e8me d'une simple commande manuelle \u00e0 une automatisation avanc\u00e9e par API ou \u00e0 des configurations manuelles \u00e0 haute s\u00e9curit\u00e9 \u00e0 travers la porte.<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"739\" height=\"370\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/0BF983E8-C247-4CE0-8013-E74F97B6F1ED.png\" alt=\"\" class=\"wp-image-1581\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/0BF983E8-C247-4CE0-8013-E74F97B6F1ED.png 739w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/0BF983E8-C247-4CE0-8013-E74F97B6F1ED-300x150.png 300w\" sizes=\"auto, (max-width: 739px) 100vw, 739px\" \/><\/figure>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group has-palette-color-6-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\"><strong><strong>M\u00e9canisme motoris\u00e9<\/strong>(MO \/ MOM) :<\/strong> <\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ces unit\u00e9s motoris\u00e9es sp\u00e9cialis\u00e9es se montent directement \u00e0 l\u2019avant des disjoncteurs moul\u00e9s (MCCB) pour actionner automatiquement le syst\u00e8me de bascule interne. En convertissant les commandes \u00e9lectriques \u00e0 distance en force m\u00e9canique fiable, elles s\u2019int\u00e8grent parfaitement aux automates programmables (PLC) via des protocoles de communication RS485 (comme Modbus RTU). C\u2019est la technologie d\u00e9finitive qui permet l\u2019isolement automatique des circuits, la r\u00e9initialisation \u00e0 distance et la gestion centralis\u00e9e compl\u00e8te du r\u00e9seau depuis la salle de contr\u00f4le.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\"><strong>Poign\u00e9es rotatives (directes et prolong\u00e9es) :<\/strong> <\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les bascules standard des disjoncteurs peuvent \u00eatre rigides et dangereuses \u00e0 actionner directement sous charge. Les poign\u00e9es rotatives directes offrent un avantage m\u00e9canique pour une manipulation plus facile, tandis que les poign\u00e9es rotatives prolong\u00e9es utilisent un arbre pour permettre aux op\u00e9rateurs de commuter le disjoncteur en toute s\u00e9curit\u00e9 depuis l'ext\u00e9rieur d'une porte d'armoire ferm\u00e9e, en maintenant une protection IP40\/IP54.<\/p>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-8 wp-block-paragraph\"><strong>Pour l'installation physique, vous devez \u00e9galement consid\u00e9rer la mani\u00e8re dont le disjoncteur se connecte \u00e0 la structure du tableau. Les disjoncteurs embrochables peuvent \u00eatre configur\u00e9s avec des bases \u00e0 connexion avant ou arri\u00e8re selon la disposition de l'armoire, la direction du c\u00e2blage et les exigences de maintenance. Les deux configurations permettent de retirer et de remplacer le disjoncteur sans d\u00e9connecter les conducteurs principaux du circuit de la base.<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"493\" height=\"246\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/32106E0B-6BED-46D0-8B64-A4958349B660.png\" alt=\"\" class=\"wp-image-1582\" style=\"width:750px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/32106E0B-6BED-46D0-8B64-A4958349B660.png 493w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/32106E0B-6BED-46D0-8B64-A4958349B660-300x150.png 300w\" sizes=\"auto, (max-width: 493px) 100vw, 493px\" \/><\/figure>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group has-palette-color-6-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\"><strong><strong><strong>Installation embrochable \u00e0 connexion avant<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un disjoncteur embrochable \u00e0 connexion avant est mont\u00e9 sur une base embrochable d\u00e9di\u00e9e, avec les c\u00e2bles principaux ou les jeux de barres connect\u00e9s aux bornes avant de la base. Le disjoncteur peut \u00eatre retir\u00e9 et remplac\u00e9 sans d\u00e9connecter les conducteurs principaux, ce qui simplifie la maintenance et r\u00e9duit le temps de remplacement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:clamp(14px, 0.875rem + ((1vw - 3.2px) * 0.078), 15px);\"><strong><strong><strong><strong>Installation embrochable \u00e0 connexion arri\u00e8re<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un disjoncteur embrochable \u00e0 connexion arri\u00e8re est \u00e9galement mont\u00e9 sur une base embrochable d\u00e9di\u00e9e, mais le circuit principal est connect\u00e9 depuis l'arri\u00e8re de la plaque de montage via des bornes arri\u00e8re ou des barres de connexion. Cette disposition offre la m\u00eame fonction pratique de remplacement tout en gardant la disposition avant de l'armoire plus propre et en r\u00e9duisant les interf\u00e9rences avec le c\u00e2blage c\u00f4t\u00e9 avant.<\/p>\n\n\n\n<p class=\"has-palette-color-9-color has-text-color has-link-color wp-elements-9 wp-block-paragraph\">Les deux configurations permettent un remplacement plus rapide du disjoncteur. La principale diff\u00e9rence r\u00e9side dans le fait que le circuit principal est connect\u00e9 aux bornes avant ou arri\u00e8re de la base embrochable.<\/p>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-large-font-size wp-elements-10\"><strong>Comment s\u00e9lectionner les bons accessoires pour disjoncteurs<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les projets \u00e9lectriques basse tension r\u00e9els, on observe souvent le m\u00eame d\u00e9fi chez les fabricants d\u2019armoires, int\u00e9grateurs syst\u00e8mes et ing\u00e9nieurs projets. Ils savent que les MCCB, MCB ou ACB peuvent n\u00e9cessiter des accessoires pour la commande \u00e0 distance, l\u2019indication d\u2019\u00e9tat, l\u2019alarme de d\u00e9faut ou la commande en porte, mais ils h\u00e9sitent souvent sur la configuration correcte des accessoires.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se fier uniquement \u00e0 des manuels produit complexes sans confirmer la structure r\u00e9elle de l\u2019armoire et les exigences de commande peut entra\u00eener des probl\u00e8mes d\u2019installation co\u00fbteux. Par exemple, choisir une mauvaise tension de commande pour un d\u00e9clencheur \u00e0 \u00e9mission peut endommager la bobine, confondre un contact auxiliaire avec un contact d\u2019alarme peut provoquer un retour d\u2019\u00e9tat incorrect, et ignorer la disposition des bornes ou l\u2019espace d\u2019installation peut affecter le c\u00e2blage, les distances d\u2019isolement et la maintenance future.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est pourquoi les accessoires de disjoncteur ne doivent pas \u00eatre s\u00e9lectionn\u00e9s uniquement par leur nom. La s\u00e9lection correcte doit tenir compte du mod\u00e8le du disjoncteur, du calibre, de la tension de commande, de la m\u00e9thode d\u2019installation, de l\u2019exigence de signal et de l\u2019environnement d\u2019application r\u00e9el.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-palette-color-6-background-color has-text-color has-background has-link-color wp-elements-11 wp-block-paragraph\"><strong>Pour simplifier ce processus complexe et prot\u00e9ger votre investissement d\u2019ing\u00e9nierie, j\u2019ai organis\u00e9 les crit\u00e8res de s\u00e9lection essentiels en \u00e9tapes pratiques et d\u00e9cisives. Voyons comment vous pouvez configurer pr\u00e9cis\u00e9ment l\u2019agencement d\u2019accessoires id\u00e9al pour votre prochain d\u00e9ploiement.<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-style-default is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u00c9tape 1 : Confirmer le type de disjoncteur, le mod\u00e8le et le calibre<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">La premi\u00e8re \u00e9tape consiste \u00e0 identifier la plateforme exacte du disjoncteur sur laquelle l\u2019accessoire sera install\u00e9. Les accessoires de disjoncteur ne sont g\u00e9n\u00e9ralement pas universels. M\u00eame lorsque deux disjoncteurs ont le m\u00eame courant assign\u00e9, des diff\u00e9rences de s\u00e9rie de produit, de calibre, de configuration des p\u00f4les, de m\u00e9canisme de man\u0153uvre interne et de dimensions de montage peuvent rendre leurs accessoires incompatibles.<br>Avant de s\u00e9lectionner un accessoire, confirmez les informations suivantes :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Type de disjoncteur : MCB, MCCB ou ACB<\/li>\n\n\n\n<li>Fabricant et s\u00e9rie de produit<\/li>\n\n\n\n<li>Mod\u00e8le complet du disjoncteur<\/li>\n\n\n\n<li>Nombre de p\u00f4les : 1P, 2P, 3P ou 4P<\/li>\n\n\n\n<li>Calibre, tel que 100 A, 250 A ou 400 A<br>Par exemple, un d\u00e9clencheur \u00e0 \u00e9mission con\u00e7u pour un MCCB de 100AF peut ne pas convenir \u00e0 un disjoncteur de 250AF, m\u00eame si les deux disjoncteurs fonctionnent au m\u00eame courant assign\u00e9. Leurs dimensions m\u00e9caniques, leurs clips de montage, leur course de man\u0153uvre et leurs positions de bornes peuvent \u00eatre compl\u00e8tement diff\u00e9rents.<br>Par cons\u00e9quent, le mod\u00e8le du disjoncteur et le calibre doivent toujours \u00eatre v\u00e9rifi\u00e9s par rapport au tableau de compatibilit\u00e9 des accessoires fourni par le fabricant.<\/li>\n<\/ul>\n\n\n\n<p class=\"has-palette-color-4-color has-palette-color-6-background-color has-text-color has-background has-link-color wp-elements-12 wp-block-paragraph\"><strong>Conseil pratique :<\/strong> Ne s\u00e9lectionnez pas un accessoire en vous basant uniquement sur le courant assign\u00e9 du disjoncteur. Fournissez toujours le num\u00e9ro de mod\u00e8le complet ou une photo claire de la plaque signal\u00e9tique du disjoncteur lors d\u2019une demande de devis.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong>\u00c9tape 2 : Faire correspondre l\u2019accessoire \u00e0 l\u2019application requise<\/strong><\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Apr\u00e8s avoir confirm\u00e9 le mod\u00e8le du disjoncteur, l\u2019\u00e9tape suivante n\u2019est pas simplement de choisir un accessoire par son nom, mais d\u2019identifier l\u2019exigence r\u00e9elle de commande, de protection ou de signalisation du syst\u00e8me \u00e9lectrique. Diff\u00e9rents accessoires peuvent \u00eatre utilis\u00e9s ensemble, mais chacun est con\u00e7u pour r\u00e9soudre une exigence d\u2019application sp\u00e9cifique. La s\u00e9lection correcte doit donc commencer par la question : <strong>Que doit faire le disjoncteur pour le syst\u00e8me ?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Au cours de mes ann\u00e9es de direction de projets d\u2019ing\u00e9nierie industrielle, j\u2019ai vu des \u00e9quipes sauter cette \u00e9tape critique et choisir des accessoires \u00e0 l\u2019aveugle dans un catalogue en se basant uniquement sur les noms. Cela entra\u00eene toujours le chaos lors de la mise en service, par exemple confondre un contact auxiliaire avec un contact d\u2019alarme, ce qui laisse l\u2019automate central compl\u00e8tement aveugle quant \u00e0 savoir si un d\u00e9clenchement \u00e9tait un d\u00e9faut de s\u00e9curit\u00e9 ou simplement une man\u0153uvre manuelle.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-text-color has-link-color has-medium-font-size wp-elements-13 wp-block-paragraph\">POUR \u00c9VITER CES ERREURS CO\u00dbTEUSES SUR LE TERRAIN, EXAMINONS COMMENT LES EXIGENCES SP\u00c9CIFIQUES DU SYST\u00c8ME DICTENT VOTRE CHOIX DE COMPOSANTS<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Si le disjoncteur doit \u00eatre d\u00e9clench\u00e9 \u00e0 distance par un syst\u00e8me d\u2019alarme incendie ou un circuit d\u2019arr\u00eat d\u2019urgence, un d\u00e9clencheur \u00e0 \u00e9mission est normalement requis.<\/li>\n\n\n\n<li>Si le disjoncteur doit s\u2019ouvrir ou emp\u00eacher la fermeture lorsque la tension de commande chute en dessous d\u2019un niveau sp\u00e9cifi\u00e9, un d\u00e9clencheur \u00e0 minimum de tension est plus adapt\u00e9.<\/li>\n\n\n\n<li>Si le syst\u00e8me de commande doit savoir si le disjoncteur est ON ou OFF, un contact auxiliaire doit \u00eatre s\u00e9lectionn\u00e9.<\/li>\n\n\n\n<li>Si le syst\u00e8me doit distinguer un d\u00e9clenchement de protection d\u2019une ouverture manuelle, un contact d\u2019alarme est requis.<\/li>\n\n\n\n<li>Si le disjoncteur doit \u00eatre ouvert ou ferm\u00e9 \u00e0 distance, un motorisateur peut \u00eatre requis.<\/li>\n\n\n\n<li>Si le disjoncteur doit \u00eatre actionn\u00e9 depuis l\u2019ext\u00e9rieur de la porte de l\u2019armoire, une poign\u00e9e rotative doit \u00eatre s\u00e9lectionn\u00e9e.<\/li>\n\n\n\n<li>Si le disjoncteur doit \u00eatre retir\u00e9 ou remplac\u00e9 rapidement sans d\u00e9connecter tous les c\u00e2bles principaux ou jeux de barres, une configuration embrochable peut \u00eatre plus adapt\u00e9e.<\/li>\n<\/ul>\n\n\n\n<p class=\"has-palette-color-4-color has-palette-color-6-background-color has-text-color has-background has-link-color wp-elements-14 wp-block-paragraph\">L\u2019accessoire doit \u00eatre s\u00e9lectionn\u00e9 selon la fonction requise plut\u00f4t que selon son apparence ou son nom de produit g\u00e9n\u00e9rique.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong><strong><strong><strong>\u00c9tape 3 : Faire correspondre la tension de commande et le type d\u2019alimentation<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">La tension de commande est l\u2019un des param\u00e8tres les plus importants lors de la s\u00e9lection d\u2019accessoires \u00e0 commande \u00e9lectrique. Les d\u00e9clencheurs \u00e0 \u00e9mission, les d\u00e9clencheurs \u00e0 minimum de tension, les bobines de fermeture et les motorisateurs sont con\u00e7us pour des plages de tension sp\u00e9cifiques.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Les tensions de commande courantes incluent :<\/li>\n\n\n\n<li>AC 24V, 36V, 48V, 110V, 220V, 230V ou 380V<\/li>\n\n\n\n<li>DC 24V, 36V, 48V, 110V, 125V ou 220V<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019accessoire s\u00e9lectionn\u00e9 doit correspondre \u00e0 la fois au niveau de tension et au type d\u2019alimentation. Par exemple, un d\u00e9clencheur \u00e0 distance 220V AC ne doit pas \u00eatre connect\u00e9 \u00e0 un circuit de commande 220V DC. Bien que la valeur de tension soit identique, la structure de la bobine et les caract\u00e9ristiques \u00e9lectriques diff\u00e8rent. Une alimentation incorrecte peut entra\u00eener un d\u00e9faut de fonctionnement, une surchauffe excessive, une d\u00e9t\u00e9rioration de la bobine ou un d\u00e9clenchement non fiable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avant de confirmer l\u2019accessoire, v\u00e9rifiez les points suivants :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Que l\u2019alimentation de commande soit AC ou DC<\/li>\n\n\n\n<li>La tension de commande nominale<\/li>\n\n\n\n<li>La plage de tension de fonctionnement admissible<\/li>\n\n\n\n<li>Si le signal est continu ou momentan\u00e9<\/li>\n\n\n\n<li>Si l\u2019accessoire reste sous tension pendant le fonctionnement normal<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-group has-palette-color-6-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\"><strong>Important :<\/strong> Les d\u00e9clencheurs \u00e0 minimum de tension sont g\u00e9n\u00e9ralement aliment\u00e9s en continu pendant que le disjoncteur fonctionne. Par cons\u00e9quent, le circuit de commande doit fournir une alimentation stable et une capacit\u00e9 de bobine suffisante.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Alimentation de l\u2019op\u00e9rateur motoris\u00e9 :<\/strong> L\u2019op\u00e9rateur motoris\u00e9 doit normalement \u00eatre aliment\u00e9 depuis le c\u00f4t\u00e9 amont du disjoncteur ou depuis une alimentation de commande ind\u00e9pendante. S\u2019il est aliment\u00e9 depuis le c\u00f4t\u00e9 aval, il peut perdre l\u2019alimentation apr\u00e8s l\u2019ouverture ou le d\u00e9clenchement du disjoncteur, emp\u00eachant ainsi toute refermeture ou r\u00e9initialisation \u00e0 distance ult\u00e9rieure.<\/p>\n<\/div>\n\n\n\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-15 wp-block-paragraph\"><strong>Personnalisation : La tension de commande de l\u2019op\u00e9rateur motoris\u00e9 peut \u00eatre personnalis\u00e9e selon l\u2019alimentation du client et les exigences du projet.<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong><strong><strong><strong>\u00c9tape 4 : V\u00e9rifier la position d\u2019installation et la compatibilit\u00e9 de l\u2019accessoire<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">De nombreux disjoncteurs modulaires et disjoncteurs \u00e0 bo\u00eetier moul\u00e9 disposent de positions ou d\u2019emplacements d\u2019installation d\u00e9sign\u00e9s pour les accessoires internes. Le nombre, la position et les combinaisons d\u2019accessoires compatibles peuvent varier selon la s\u00e9rie du produit, la taille du ch\u00e2ssis et la configuration des p\u00f4les.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avant de commander, confirmez les points suivants :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Si l\u2019accessoire est install\u00e9 \u00e0 l\u2019int\u00e9rieur ou \u00e0 l\u2019ext\u00e9rieur<\/li>\n\n\n\n<li>S\u2019il est mont\u00e9 du c\u00f4t\u00e9 gauche ou du c\u00f4t\u00e9 droit<\/li>\n\n\n\n<li>Si un emplacement peut accepter plus d\u2019un module de contact<\/li>\n\n\n\n<li>Si les accessoires s\u00e9lectionn\u00e9s peuvent \u00eatre install\u00e9s ensemble<\/li>\n\n\n\n<li>Si des borniers suppl\u00e9mentaires ou des fils de c\u00e2blage sont n\u00e9cessaires<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Certains MCCB, notamment les MCCB \u00e0 courant r\u00e9siduel, disposent d\u2019un espace interne limit\u00e9 pour les accessoires. Dans certains mod\u00e8les, une seule position d\u2019accessoire interne est disponible, donc un d\u00e9clencheur \u00e0 distance standard et un contact auxiliaire s\u00e9par\u00e9 ne peuvent pas \u00eatre install\u00e9s simultan\u00e9ment. Dans ce cas, un module int\u00e9gr\u00e9 d\u00e9clencheur \u00e0 distance et contact auxiliaire peut \u00eatre choisi lorsque le d\u00e9clenchement \u00e0 distance et le retour d\u2019\u00e9tat du disjoncteur sont requis. La disposition de montage des accessoires peut aussi varier selon les s\u00e9ries MCCB. Par exemple, le d\u00e9clencheur \u00e0 distance peut \u00eatre install\u00e9 \u00e0 gauche dans un mod\u00e8le et \u00e0 droite dans un autre, tandis que le contact auxiliaire ou de signalisation occupe une position diff\u00e9rente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Par cons\u00e9quent, la compatibilit\u00e9 des accessoires ne peut \u00eatre d\u00e9termin\u00e9e uniquement par le nom de l\u2019accessoire ou le courant nominal du disjoncteur. La s\u00e9rie MCCB exacte, la taille du bo\u00eetier, la fonction de protection diff\u00e9rentiel, la configuration des p\u00f4les et la disposition interne des accessoires doivent \u00eatre confirm\u00e9es avant la commande.<\/p>\n\n\n\n<div class=\"wp-block-group has-palette-color-6-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\"><strong>Conseil pratique :<\/strong> Si le MCCB ne dispose que d\u2019un emplacement d\u2019accessoire disponible, v\u00e9rifiez si un module accessoire int\u00e9gr\u00e9, tel qu\u2019un d\u00e9clencheur \u00e0 distance avec contact auxiliaire, est disponible pour cette s\u00e9rie de disjoncteurs.<\/p>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-16 wp-block-paragraph\">La s\u00e9lection des accessoires de disjoncteur appropri\u00e9s ne se limite pas \u00e0 identifier le nom de l\u2019accessoire. Le mod\u00e8le du disjoncteur, la taille du ch\u00e2ssis, la fonction requise, la tension de commande, la position d\u2019installation et la compatibilit\u00e9 des accessoires doivent tous \u00eatre confirm\u00e9s ensemble. Une configuration correcte doit satisfaire \u00e0 la fois aux exigences de commande \u00e9lectrique et aux conditions r\u00e9elles d\u2019installation dans l\u2019armoire.<\/p>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong><strong><strong><strong><strong>\u00c9tape 5 : Options d'installation et de raccordement du disjoncteur enfichable<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">En plus des fonctions \u00e9lectriques, la m\u00e9thode d'installation et de raccordement du disjoncteur peut \u00e9galement influencer le choix des accessoires. Diff\u00e9rentes configurations enfichables peuvent n\u00e9cessiter des embases, des bornes, des dispositions de montage et des structures d'armoire diff\u00e9rentes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><strong>Installation embrochable \u00e0 connexion avant<\/strong><\/strong>\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un disjoncteur enfichable \u00e0 connexion frontale est mont\u00e9 sur une base enfichable d\u00e9di\u00e9e, avec les c\u00e2bles ou barres omnibus du circuit principal connect\u00e9s par l\u2019avant. Le disjoncteur peut \u00eatre retir\u00e9 et remplac\u00e9 sans d\u00e9connecter les conducteurs du circuit principal de la base, ce qui r\u00e9duit le temps de maintenance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><strong>Installation embrochable \u00e0 connexion arri\u00e8re<\/strong><\/strong>\uff1a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un disjoncteur enfichable \u00e0 raccordement arri\u00e8re est \u00e9galement mont\u00e9 sur une embase enfichable d\u00e9di\u00e9e, mais le circuit principal est raccord\u00e9 depuis l'arri\u00e8re de la plaque de montage par des bornes arri\u00e8re ou des barres de liaison. Il offre la m\u00eame fonction pratique de remplacement tout en permettant une disposition plus \u00e9pur\u00e9e de l'armoire \u00e0 l'avant.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-palette-color-6-background-color has-text-color has-background has-link-color wp-elements-17 wp-block-paragraph\">Les deux configurations permettent un remplacement plus rapide du disjoncteur. La principale diff\u00e9rence r\u00e9side dans le sens du raccordement du circuit principal et dans les exigences d'agencement de l'armoire correspondantes.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-large-font-size wp-elements-18\"><strong>Liste de contr\u00f4le pour la s\u00e9lection des accessoires du disjoncteur<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>\u00c9l\u00e9ment de s\u00e9lection<\/strong><\/th><th><strong>\u00c9l\u00e9ments \u00e0 confirmer<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Type de disjoncteur<\/td><td>MCB, MCCB, MCCB \u00e0 courant r\u00e9siduel ou ACB<\/td><\/tr><tr><td>Fabricant et s\u00e9rie<\/td><td>S\u00e9rie compl\u00e8te du produit<\/td><\/tr><tr><td>Mod\u00e8le complet<\/td><td>Num\u00e9ro de mod\u00e8le complet du disjoncteur<\/td><\/tr><tr><td>Taille de ch\u00e2ssis<\/td><td>100AF, 250AF, 400AF, etc.<\/td><\/tr><tr><td>Nombre de p\u00f4les<\/td><td>1P, 2P, 3P ou 4P<\/td><\/tr><tr><td>Fonction requise<\/td><td>D\u00e9clenchement \u00e0 distance, protection contre les sous-tensions, retour d'\u00e9tat, alarme de d\u00e9faut, commande \u00e0 distance ou verrouillage<\/td><\/tr><tr><td>Tension de commande<\/td><td>Tension nominale et type d\u2019alimentation AC\/DC<\/td><\/tr><tr><td>Signal de commande<\/td><td>Continu ou momentan\u00e9<\/td><\/tr><tr><td>Position de l'accessoire<\/td><td>Interne, externe, c\u00f4t\u00e9 gauche ou c\u00f4t\u00e9 droit<\/td><\/tr><tr><td>Combinaison d'accessoires<\/td><td>Accessoire s\u00e9par\u00e9 ou module int\u00e9gr\u00e9<\/td><\/tr><tr><td>M\u00e9thode de connexion<\/td><td>Connexion avant ou connexion arri\u00e8re<\/td><\/tr><tr><td>M\u00e9thode d'installation<\/td><td>Montage fixe ou embrochable<\/td><\/tr><tr><td>Conditions de l'armoire<\/td><td>Profondeur, espace de c\u00e2blage, longueur d'arbre et d\u00e9gagement de maintenance<\/td><\/tr><tr><td>Documents du projet<\/td><td>Photo de la plaque signal\u00e9tique, sch\u00e9ma de commande, plan d'armoire et exigences techniques<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-palette-color-4-color has-palette-color-6-background-color has-text-color has-background has-link-color wp-elements-19 wp-block-paragraph\">Si l'une des informations ci-dessus est incertaine, fournissez le mod\u00e8le complet du disjoncteur, la photo de la plaque signal\u00e9tique et les plans du projet au fournisseur avant de passer la commande.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-large-font-size wp-elements-20\"><strong>Erreurs courantes lors de la s\u00e9lection des accessoires de disjoncteur<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"905\" height=\"302\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/39FCD868-2D64-4E54-BF27-21D610E34788.png\" alt=\"\" class=\"wp-image-1583\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/39FCD868-2D64-4E54-BF27-21D610E34788.png 905w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/39FCD868-2D64-4E54-BF27-21D610E34788-300x100.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/39FCD868-2D64-4E54-BF27-21D610E34788-768x256.png 768w\" sizes=\"auto, (max-width: 905px) 100vw, 905px\" \/><\/figure>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00eame les tableautiers et ing\u00e9nieurs de projet exp\u00e9riment\u00e9s peuvent commettre des erreurs de s\u00e9lection d'accessoires lorsque le mod\u00e8le du disjoncteur, la tension de commande, la structure d'installation ou les exigences de signal ne sont pas enti\u00e8rement confirm\u00e9s. Voici quelques-uns des probl\u00e8mes les plus courants rencontr\u00e9s lors de la s\u00e9lection des accessoires de disjoncteur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>S\u00e9lectionner les accessoires uniquement selon le courant assign\u00e9<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les accessoires de disjoncteur ne doivent pas \u00eatre s\u00e9lectionn\u00e9s uniquement selon le courant assign\u00e9 du disjoncteur. Deux disjoncteurs ayant le m\u00eame courant assign\u00e9 peuvent appartenir \u00e0 des s\u00e9ries de produits ou \u00e0 des tailles de ch\u00e2ssis diff\u00e9rentes, et leurs structures internes, dimensions de montage et positions des accessoires peuvent \u00eatre compl\u00e8tement diff\u00e9rentes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Comment l'\u00e9viter :<\/strong> Confirmez toujours le mod\u00e8le complet du disjoncteur, la s\u00e9rie de produits, la taille du ch\u00e2ssis et le nombre de p\u00f4les.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ignorer le mod\u00e8le complet du disjoncteur<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fournir uniquement des informations telles que \u201c MCCB 250A \u201d n'est g\u00e9n\u00e9ralement pas suffisant pour identifier le bon accessoire. Le num\u00e9ro de mod\u00e8le complet peut inclure des informations importantes sur la s\u00e9rie du disjoncteur, la taille du ch\u00e2ssis, le pouvoir de coupure, la configuration des p\u00f4les et le type de protection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ceci est particuli\u00e8rement important pour les MCCB \u00e0 courant r\u00e9siduel, les MCCB \u00e9lectroniques et les disjoncteurs avec des structures internes sp\u00e9ciales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Comment l'\u00e9viter :<\/strong> Fournissez le num\u00e9ro de mod\u00e8le complet ou une photo claire de la plaque signal\u00e9tique du disjoncteur.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Confondre les contacts auxiliaires avec les contacts d'alarme<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les contacts auxiliaires et les contacts d'alarme fournissent tous deux des signaux de retour \u00e9lectriques, mais ils indiquent des conditions diff\u00e9rentes.Un contact auxiliaire indique normalement si le disjoncteur est ON ou OFF. Un contact d'alarme indique si le disjoncteur s'est d\u00e9clench\u00e9 en raison d'une surcharge, d'un court-circuit ou d'un autre \u00e9v\u00e9nement de protection.Si le mauvais contact est s\u00e9lectionn\u00e9, l'automate ou le syst\u00e8me de surveillance peut recevoir des informations d'\u00e9tat incorrectes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Comment l'\u00e9viter :<\/strong> Confirmez si le syst\u00e8me n\u00e9cessite un retour de position ou un retour de d\u00e9clenchement sur d\u00e9faut.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ne pas confirmer la compatibilit\u00e9 de la base embrochable et de la connexion<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une base embrochable doit correspondre exactement \u00e0 la s\u00e9rie du disjoncteur, \u00e0 la taille du ch\u00e2ssis, au nombre de p\u00f4les et \u00e0 la m\u00e9thode de connexion.Les configurations embrochables \u00e0 connexion avant et \u00e0 connexion arri\u00e8re peuvent utiliser des bases, des bornes, des barres de connexion et des structures d'armoire diff\u00e9rentes.Une base s\u00e9lectionn\u00e9e uniquement selon le courant assign\u00e9 peut ne pas s'adapter correctement au disjoncteur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Comment l'\u00e9viter :<\/strong> Confirmez si le syst\u00e8me n\u00e9cessite une configuration embrochable \u00e0 connexion avant ou \u00e0 connexion arri\u00e8re avant de commander.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Alimenter le moteur de commande depuis le c\u00f4t\u00e9 charge<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si le moteur de commande est aliment\u00e9 depuis le c\u00f4t\u00e9 charge du disjoncteur, il peut perdre l'alimentation apr\u00e8s l'ouverture ou le d\u00e9clenchement du disjoncteur.Cela peut emp\u00eacher la refermeture ou la r\u00e9initialisation \u00e0 distance du disjoncteur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Comment l'\u00e9viter :<\/strong> Le moteur de commande doit normalement \u00eatre aliment\u00e9 depuis le c\u00f4t\u00e9 ligne du disjoncteur ou depuis une source d'alimentation de commande ind\u00e9pendante, selon la conception du syst\u00e8me.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>6.<strong>Ignorer l'espace de l'armoire et le d\u00e9gagement m\u00e9canique<\/strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00eame si l\u2019accessoire est \u00e9lectriquement compatible, il peut rester impossible \u00e0 installer si l\u2019espace dans l\u2019armoire est insuffisant. Les commandes motoris\u00e9es, les poign\u00e9es rotatives, les socles embrochables, les bornes arri\u00e8re, les caches-bornes et les cosses de c\u00e2ble exigent tous un espace d\u2019installation suppl\u00e9mentaire. Un d\u00e9gagement insuffisant peut affecter le c\u00e2blage, la fermeture de la porte de l\u2019armoire, le fonctionnement et la maintenance future.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Comment l'\u00e9viter :<\/strong> V\u00e9rifiez le plan de l\u2019armoire, les dimensions du disjoncteur, les dimensions des accessoires, le cheminement des c\u00e2bles et l\u2019espace de maintenance avant de confirmer la commande.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-group has-palette-color-6-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-21 wp-block-paragraph\">La plupart des erreurs de s\u00e9lection d\u2019accessoires de disjoncteur peuvent \u00eatre \u00e9vit\u00e9es en confirmant, avant la commande, le mod\u00e8le complet du disjoncteur, la tension de commande, la fonction requise, l\u2019agencement des accessoires internes, la m\u00e9thode d\u2019installation et les conditions de l\u2019armoire.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-22 wp-block-paragraph\">Lorsque la configuration des accessoires est incertaine, fournissez au fournisseur la photo de la plaque signal\u00e9tique du disjoncteur, le sch\u00e9ma de commande et le plan de l\u2019armoire pour v\u00e9rification de compatibilit\u00e9.<\/p>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-large-font-size wp-elements-23\">Questions fr\u00e9quemment pos\u00e9es sur les accessoires de disjoncteur<\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Puis-je utiliser les accessoires JUTRION comme remplacements ou am\u00e9liorations de haute qualit\u00e9 pour les grandes marques de disjoncteurs ?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Absolument. Chez JUTRION, notre gamme compl\u00e8te d\u2019accessoires internes et externes est con\u00e7ue sur mesure et moul\u00e9e avec pr\u00e9cision pour correspondre strictement aux profils de liaison m\u00e9canique et aux sp\u00e9cifications \u00e9lectriques des disjoncteurs basse tension standard du march\u00e9 mondial. Tant que vous s\u00e9lectionnez le mod\u00e8le de r\u00e9f\u00e9rence crois\u00e9e v\u00e9rifi\u00e9 dans notre catalogue, nos composants offrent une endurance m\u00e9canique identique et une int\u00e9gration parfaite, proposant aux \u00e9quipes d\u2019ing\u00e9nierie une alternative tr\u00e8s \u00e9conomique avec des d\u00e9lais de production nettement plus courts.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Les accessoires de disjoncteur sont-ils universels ?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Non. Les accessoires de disjoncteur sont g\u00e9n\u00e9ralement con\u00e7us pour des s\u00e9ries de produits, des tailles de ch\u00e2ssis, des configurations de p\u00f4les et des m\u00e9canismes internes sp\u00e9cifiques. M\u00eame si deux disjoncteurs ont le m\u00eame courant assign\u00e9, leurs accessoires peuvent ne pas \u00eatre interchangeables.<br>Confirmez toujours le mod\u00e8le complet du disjoncteur et la compatibilit\u00e9 des accessoires avant de commander.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Quelle est la diff\u00e9rence entre un contact auxiliaire et un contact d\u2019alarme ?<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un contact auxiliaire indique la position de fonctionnement du disjoncteur, par exemple ON ou OFF. Un contact d\u2019alarme indique que le disjoncteur a d\u00e9clench\u00e9 en raison d\u2019une surcharge, d\u2019un court-circuit, d\u2019un d\u00e9faut \u00e0 la terre ou d\u2019un autre \u00e9v\u00e9nement de protection.<br>Un contact auxiliaire est utilis\u00e9 pour le retour de position, tandis qu\u2019un contact d\u2019alarme est utilis\u00e9 pour l\u2019indication de d\u00e9clenchement sur d\u00e9faut.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Puis-je installer un d\u00e9clencheur \u00e0 \u00e9mission de tension et un d\u00e9clencheur \u00e0 manque de tension dans le m\u00eame disjoncteur simultan\u00e9ment ?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cela d\u00e9pend strictement de la taille du cadre du disjoncteur et de la configuration de sa cavit\u00e9 interne. Dans les appareils compacts \u00e0 courant plus faible (comme les cadres 125A), il y a souvent un seul emplacement interne physique d\u00e9di\u00e9 aux bobines de d\u00e9clenchement sous tension, ce qui signifie que vous devez choisir entre un d\u00e9clencheur shunt ou un UVR. Cependant, dans les tailles de cadre plus grandes (comme 400A ou 800A), plusieurs emplacements ind\u00e9pendants sont g\u00e9n\u00e9ralement pr\u00e9vus, vous permettant de combiner parfaitement les deux accessoires internes. Lors de la configuration de votre projet, notre \u00e9quipe d\u2019ing\u00e9nierie JUTRION peut vous fournir une disposition pr\u00e9cise de la combinaison en fonction de vos contraintes d\u2019enveloppe.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Quelle est la principale diff\u00e9rence op\u00e9rationnelle entre un d\u00e9clencheur \u00e0 \u00e9mission de tension et un d\u00e9clencheur \u00e0 manque de tension (UVR) ?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La diff\u00e9rence fondamentale r\u00e9side dans leur logique d\u2019activation. Un d\u00e9clencheur par shunt n\u00e9cessite une impulsion \u00e9lectrique active (application de tension \u00e0 la bobine) pour d\u00e9clencher m\u00e9caniquement le disjoncteur \u00e0 distance, ce qui le rend parfait pour les liaisons d\u2019alarme incendie. \u00c0 l\u2019inverse, un d\u00e9clencheur sous-tension (UVR) maintient le disjoncteur ferm\u00e9 tant que la tension du r\u00e9seau standard est pr\u00e9sente ; il d\u00e9clenche automatiquement le disjoncteur lorsque la tension de commande descend en dessous d\u2019un seuil s\u00e9curis\u00e9 (g\u00e9n\u00e9ralement entre 35 % et 70 % de la tension nominale) ou en cas de coupure totale. Cela rend l\u2019UVR id\u00e9al pour prot\u00e9ger les moteurs en aval contre les baisses soudaines de tension du r\u00e9seau.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Comment JUTRION garantit-elle la fiabilit\u00e9 \u00e0 long terme et l\u2019endurance m\u00e9canique de ses accessoires internes sur des milliers de cycles de man\u0153uvre ?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La d\u00e9faillance sur le terrain n\u2019est pas une option lorsque la s\u00e9curit\u00e9 est en jeu. Chez JUTRION, nous ne consid\u00e9rons pas nos accessoires comme de simples pi\u00e8ces en plastique moul\u00e9 et en cuivre, mais comme le r\u00e9seau neuronal de pr\u00e9cision de votre syst\u00e8me de distribution \u00e9lectrique. Chaque lot de nos d\u00e9clencheurs \u00e0 \u00e9mission, contacts auxiliaires et commandes motoris\u00e9es est soumis \u00e0 des essais rigoureux et automatis\u00e9s de fatigue et de rigidit\u00e9 di\u00e9lectrique dans nos laboratoires de conformit\u00e9. Nous simulons des environnements industriels s\u00e9v\u00e8res, garantissant que nos micro-interrupteurs et nos bobines renforc\u00e9es conservent des valeurs d\u2019endurance m\u00e9canique et \u00e9lectrique pleinement conformes aux normes CEI. En concevant nos composants avec des polym\u00e8res haute performance r\u00e9sistants \u00e0 la chaleur et des contacts en alliage d\u2019argent de premi\u00e8re qualit\u00e9, JUTRION garantit un retour de signal stable et une commande \u00e0 distance instantan\u00e9e m\u00eame apr\u00e8s des ann\u00e9es de cycles de man\u0153uvre exigeants.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Les conceptions des disjoncteurs varient consid\u00e9rablement selon les marques mondiales. JUTRION peut-elle r\u00e9ellement garantir une compatibilit\u00e9 physique entre diff\u00e9rents fabricants ?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui, nous le pouvons. Cette capacit\u00e9 d\u2019adaptation universelle est pr\u00e9cis\u00e9ment la raison pour laquelle des clients internationaux collaborent avec nous. Au fil des ann\u00e9es, JUTRION a construit et mis \u00e0 jour en continu une vaste base de donn\u00e9es d\u2019ing\u00e9nierie et une biblioth\u00e8que de matrices de moules de pr\u00e9cision. Aujourd\u2019hui, nos accessoires internes et externes tr\u00e8s polyvalents peuvent s\u2019adapter parfaitement \u00e0 plus de 99 % des disjoncteurs moul\u00e9s basse tension (MCCB) et des disjoncteurs miniatures (MCB) disponibles sur le march\u00e9 mondial. Que votre tableau \u00e9lectrique repose sur des conceptions europ\u00e9ennes standard, des formats asiatiques traditionnels ou des grandes marques multinationales majeures, notre \u00e9quipe d\u2019ing\u00e9nierie peut imm\u00e9diatement vous proposer la variante d\u2019accessoire JUTRION pr\u00e9cise con\u00e7ue pour s\u2019adapter exactement \u00e0 ce bo\u00eetier interne et \u00e0 ce profil de liaison m\u00e9canique.<\/p>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-large-font-size wp-elements-24\"><strong>Besoin d'aide pour s\u00e9lectionner des accessoires de disjoncteur compatibles ?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choisir le bon accessoire de disjoncteur exige plus que de faire correspondre le nom de l'accessoire. Le mod\u00e8le du disjoncteur, la taille du ch\u00e2ssis, la tension de commande, la position d'installation, la m\u00e9thode de connexion et les exigences du projet doivent tous \u00eatre v\u00e9rifi\u00e9s ensemble.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-palette-color-6-background-color has-text-color has-background has-link-color wp-elements-25 wp-block-paragraph\">Fournissez \u00e0 JUTRION les informations suivantes :<br>Mod\u00e8le complet du disjoncteur ou photo de la plaque signal\u00e9tique<br>Fonction d'accessoire requise<br>Tension de commande et type d\u2019alimentation AC\/DC<br>M\u00e9thode d'installation et quantit\u00e9 du projet<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Notre \u00e9quipe d'ing\u00e9nierie v\u00e9rifiera la compatibilit\u00e9 des accessoires et recommandera une configuration adapt\u00e9e \u00e0 votre projet \u00e9lectrique.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-1169\"><a class=\"wp-block-button__link wp-element-button\"><strong>OBTENEZ VOTRE CONFIGURATION D'ACCESSOIRE<\/strong><\/a><\/div>\n<\/div>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Quick Answer: What Are Circuit Breaker Accessories? According to IEC 60947-2 (the international standard governing low-voltage switchgear and controlgear), a circuit breaker&#8217;s primary duty is to safely make, carry, and break currents under normal and specified abnormal conditions. However, a bare breaker operates as an isolated mechanical switch. Circuit breaker accessories are the standardized, modular [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1585,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1569","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-guides"],"blocksy_meta":{"content_style_source":"inherit","vertical_spacing_source":"custom","content_area_spacing":"both","has_hero_section":"enabled","hero_section":"type-1","pageTitleFont":{"family":"Default","variation":"Default","size":"30px","line-height":"CT_CSS_SKIP_RULE","letter-spacing":"CT_CSS_SKIP_RULE","text-transform":"CT_CSS_SKIP_RULE","text-decoration":"CT_CSS_SKIP_RULE"},"styles_descriptor":{"styles":{"desktop":"[data-prefix=\"single_blog_post\"] .entry-header .page-title {--theme-font-size:30px;--theme-heading-color:#444444;} [data-prefix=\"single_blog_post\"] .entry-header .entry-meta {--theme-font-weight:600;--theme-text-transform:uppercase;--theme-font-size:12px;--theme-line-height:1.3;--theme-text-color:#000000;--theme-link-hover-color:#979797;} [data-prefix=\"single_blog_post\"] .entry-header .page-description {--theme-text-color:#7f7f7f;}","tablet":"","mobile":""},"google_fonts":[],"version":6},"page_structure_type":"type-1","hero_elements":[{"id":"custom_title","enabled":true,"heading_tag":"h1","title":"Accueil","__id":"MFcRBErKz32VlXE-UIIqf"},{"id":"custom_description","enabled":true,"description_visibility":{"desktop":true,"tablet":true,"mobile":false},"__id":"-E3irv7aotLni2MIkwQVb"},{"id":"custom_meta","enabled":true,"meta_elements":[{"id":"author","enabled":true,"label":"\u4f5c\u8005","has_author_avatar":"no","avatar_size":25,"__id":"np1iBgRUDYOX-9f7zCsWS"},{"id":"post_date","enabled":true,"label":"\u4e8e","date_format_source":"default","date_format":"M j, Y","__id":"nwSU68ntZpOs6T5rDCUR8"},{"id":"updated_date","enabled":false,"label":"\u4e8e","date_format_source":"default","date_format":"M j, Y","__id":"KjyOcY8TELthfoOgI-SH7"},{"id":"categories","enabled":false,"label":"\u4f4d\u4e8e","style":"simple","__id":"PjG5t4yl1Jk5pKW9n4EMl"},{"id":"comments","enabled":false,"__id":"EUpFq6lkiPAIdi3rEbFFo"}],"page_meta_elements":{"joined":true,"articles_count":true,"comments":true},"__id":"FokJvC3LvAYCL5XKL_rFT","meta_divider":"line"},{"id":"breadcrumbs","enabled":false,"__id":"BH-q54unUYqspjGYRBFcs"}],"pageTitleFontColor":{"default":{"color":"#444444"}},"pageMetaFontColor":{"default":{"color":"#000000"},"hover":{"color":"#979797"}},"pageExcerptColor":{"default":{"color":"#7f7f7f"}}},"_links":{"self":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/posts\/1569","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/comments?post=1569"}],"version-history":[{"count":6,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/posts\/1569\/revisions"}],"predecessor-version":[{"id":1584,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/posts\/1569\/revisions\/1584"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/media\/1585"}],"wp:attachment":[{"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/media?parent=1569"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/categories?post=1569"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jutrion.com\/fr\/wp-json\/wp\/v2\/tags?post=1569"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}