Free electrical engineering tools

Turn electrical inputs into usable design parameters.

A connected set of engineering calculators for circuit protection, motor control, surge protection, voltage monitoring, and solar DC applications.

25parameter tools
6engineering categories
IECfocused reference
JUTRION parameter path Reference mode
01 / InputProject dataLoad · source · installation
02 / ProcessEngineering checkFormula + conditional logic
03 / OutputRequired parametersCurrent · rating · limits
Direct calculationNumeric resultFormula-derived
Conditional checkSelection rangeRequires verification

Guided workflow

The JUTRION calculation chain

Move from source and load data to protection parameters through smaller checks that can be reviewed independently.

01ACalculate load currentPower, voltage and phase → Ib
02InEstimate breaker ratingIb, margin and cable Iz → In
03kACheck fault currentSource impedance → prospective Isc
04Confirm device dutyIsc and voltage → Icu check
Protection relationshipIb ≤ In ≤ Iz+Icu ≥ prospective fault current

Engineering calculators

Find the right calculation

JT–CP–01Direct calculation

ការការពារសៀគ្វី

Short-Circuit Current & Icu Calculator

Estimate transformer-secondary terminal fault current, then compare it with the breaker breaking capacity at the operating voltage.

InputskVA · VLL · Z% · phase
OutputsIn · Isc · Icu check

Optional: upstream contribution and feeder impedance for a fuller result.

Open calculator
JT–CP–03Conditional check

ការការពារសៀគ្វី

MCB Inrush & Curve Checker

Compare equipment inrush and available fault current with the magnetic-trip bands of B, C, and D curves.

InputsIn · inrush · duration · Isc
Outputsband comparison · screen

Not a guarantee: final performance follows the exact manufacturer curve.

Open calculator
JT–SV–01Conditional check

ការកើនឡើងតង់ស្យុង & វ៉ុល

SPD Parameter Selection Check

Translate supply arrangement, installation point, lightning exposure, and equipment withstand into a preliminary SPD requirement.

Inputsstandard · V · TN/TT/IT · location
Outputstype · Uc · Up · connection

Important: Up is a coordination target and product value, not calculated from voltage alone.

Open calculator
JT–PD–01Direct calculation

ម៉ូទ័រ និងការប្តូរ

ATS Sizing Calculator

Convert the load into design current, the AC-31/AC-33 category, a standard ATS rating, and the pole configuration.

InputskW/kVA · V · PF · character
OutputsA · category · rating · poles

Decision: switched neutral and poles depend on the earthing and source.

Open calculator
JT–MC–02Direct calculation

ម៉ូទ័រ និងការប្តូរ

Generator Capacity for ATS

Estimate generator kW and kVA from diversified running load, the largest starting step, reserve, and environmental derating.

Inputsrun kW · start kVA · reserve
Outputsgenset kW/kVA · ATS A

Required: confirm voltage dip and transient with the generator maker.

Open calculator
JT–CP–07Calculation + check

ការការពារសៀគ្វី

Breaker Accessory Power Calculator

Estimate control-supply demand for shunt trips, undervoltage releases, motor operators, and related breaker accessories.

Inputsaccessory · coil V · VA · qty
Outputspeak VA · steady VA · margin

Compatibility: series, frame, AC/DC, contacts, and mounting must match.

Open calculator
JT–CP–05Conditional check

ការការពារសៀគ្វី

AFDD Requirement & Selection

Collect circuit and market information to define an AFDD or integrated AFDD-RCBO requirement and architecture.

Inputsmarket · premises · circuit · In
Outputsstatus · architecture · rating

Not universal: whether AFDD is required depends on local rules.

Open calculator
JT–DC–01Direct calculation

ពន្លឺព្រះអាទិត្យ និង DC

PV String Voltage Calculator

Calculate cold-condition string open-circuit voltage and screen the module count against inverter voltage limits.

InputsVoc · βVoc · Tmin · Vdc max
Outputscold Voc · max modules

Required: use module and inverter datasheet limits.

Open calculator
JT–DC–07Calculation + check

ពន្លឺព្រះអាទិត្យ និង DC

PV DC ATS Calculator

Calculate DC design current and organize the voltage, pole, source, and transfer requirements for a solar or battery DC ATS.

InputskW/A · Vdc · sources · polarity
OutputsA · Ue · poles · check

DC-specific: verify switching, isolation, and arc interruption at Vdc.

Open calculator
JT–DC–02Calculation + check

ពន្លឺព្រះអាទិត្យ និង DC

DC MCB & MCCB Rating Calculator

Calculate DC design current and screen rated current, operating voltage, poles, cable capacity, and breaking capacity.

Inputssource · Idc · Vdc · Iz · Isc
OutputsIn · Ue · poles · Icu

Critical: DC poles and series connection follow the breaker documentation.

Open calculator
JT–DC–03Direct calculation

ពន្លឺព្រះអាទិត្យ និង DC

PV String Fuse Rating Calculator

Calculate a reference gPV fuse-current range and compare it with the module maximum series-fuse rating.

InputsIsc · strings · factor · max fuse
Outputsmin A · max A · pass/fail

Standard route: design multipliers selectable for the applicable standard.

Open calculator
JT–DC–04Direct calculation

ពន្លឺព្រះអាទិត្យ និង DC

PV Combiner Box Rating Calculator

Aggregate string current and voltage into reference input-fuse, output-device, busbar, isolator, and SPD requirements.

Inputsstrings · Isc · cold Voc
Outputsfuse · output A/V · SPD

System tool: ratings remain subject to enclosure temperature.

Open calculator
JT–DC–05Calculation + check

ពន្លឺព្រះអាទិត្យ និង DC

ម៉ាស៊ីនគណនាកម្រិត PV DC Isolator

Screen minimum voltage, current, utilization category, and pole configuration for a PV array isolation point.

Inputscold Voc · Isc · duty · topology
OutputsUe · Ie · poles · category

Product-specific: verify the switching configuration at Vdc.

Open calculator
JT–DC–06Calculation + check

ពន្លឺព្រះអាទិត្យ និង DC

PV SPD Minimum Ucpv Calculator

Derive a minimum continuous operating voltage from the cold-condition array voltage, then screen SPD type and connection topology.

Inputscold Voc · topology · earthing
Outputsmin Ucpv · type · connection

Do not use nominal: the max temperature-corrected Voc governs.

Open calculator
JT–MC–01Direct calculation

ម៉ូទ័រ និងការប្តូរ

AC Contactor Motor Sizing

Estimate motor full-load current and a preliminary AC-3 operational-current requirement for normal starting and stopping duty.

InputskW · V · phase · η · PF
OutputsFLC · minimum Ie

Product stage: coil, poles, auxiliaries, and life are selected after.

Open calculator
JT–MC–03Calculation + check

ម៉ូទ័រ និងការប្តូរ

Motor Overload Relay Setting

Translate motor nameplate current and application duty into a preliminary overload setting and trip-class check.

Inputsnameplate A · SF · start · ambient
Outputssetting · band · trip class

Motor data governs: use the nameplate current for final adjustment.

Open calculator
JT–SV–02Conditional check

ការកើនឡើងតង់ស្យុង & វ៉ុល

Voltage Threshold & Delay Setting

Build a preliminary voltage window, trip delay, and reconnection delay from the equipment tolerance and application behavior.

InputsVn · window · application
OutputsU · delay range

Application setting: delay rides through disturbances, not calculated from load.

Open calculator
JT–PD–02Direct calculation

ការចែកចាយថាមពល

Load Current & Power Calculator

Convert between kW, kVA, and current for DC, single-phase, and balanced three-phase loads.

Inputsmode · kW/kVA/A · V · PF
OutputsA · kW · kVA

Supports: preliminary sizing for breakers, ATS, contactors, CTs.

Open calculator
JT–PD–03Direct calculation

ការចែកចាយថាមពល

Cable Voltage Drop Calculator

Estimate conductor voltage drop and percentage loss for DC, single-phase, and three-phase circuits.

InputsA · V · length · mm² · material
OutputsΔV · Vd% · end voltage

Boundary: resistance and reactance must match the conductor.

Open calculator
JT–PD–04Direct calculation

ការចែកចាយថាមពល

Cable Derating & Iz Calculator

Combine correction factors and check whether the corrected cable capacity remains above the selected breaker rating.

Inputsbase Iz · Ca · Cg · Ci
Outputscorrected Iz · In≤Iz

Required: base ampacity and factors from the adopted wiring tables.

Open calculator
JT–PD–05Direct calculation

ការចែកចាយថាមពល

Transformer Current Calculator

Calculate transformer line current on both sides from the kVA rating, voltage, and phase arrangement.

InputskVA · primary V · sec V · phase
Outputsprimary A · secondary A

Supports: preliminary CT, ATS, MCCB, and ACB planning.

Open calculator
JT–PM–01Calculation + check

ការវាស់ថាមពល

CT Ratio & Burden Calculator

Select a reference CT ratio and estimate total secondary burden from meters, relays, and connecting leads.

Inputsprimary A · 1/5 A · lead · VA
Outputsratio · burden VA · use

Product check: accuracy class and saturation need the exact CT data.

Open calculator
JT–CP–04Conditional check

ការការពារសៀគ្វី

RCCB & RCBO Parameter Check

Organize residual-current waveform, protection purpose, load current, and expected standing leakage into a preliminary requirement.

Inputsload · waveform · leakage · poles
OutputsRCD type · IΔn · In check

Code dependent: sensitivity and selectivity follow the market rules.

Open calculator
JT–CP–06Calculation + check

ការការពារសៀគ្វី

ACB Frame & LSIG Worksheet

Build preliminary frame-current and LSIG setting ranges from feeder load, conductor capacity, fault level, and coordination.

InputsIb · Iz · Isc · downstream
Outputsframe · Ir · Isd · Ii · Ig

Coordination study: final settings need manufacturer curves.

Open calculator

After the calculation

Have the parameters but still need a suitable product?

Send the calculation summary to JUTRION when you need help checking an available configuration for the destination market.