{"id":1595,"date":"2026-07-13T11:29:53","date_gmt":"2026-07-13T03:29:53","guid":{"rendered":"https:\/\/jutrion.com\/?page_id=1595"},"modified":"2026-08-07T10:36:43","modified_gmt":"2026-08-07T02:36:43","slug":"jutrion-jrspd-40dc-series-solar-pv-dc-surge-protective-device","status":"publish","type":"page","link":"https:\/\/jutrion.com\/lo\/products\/jutrion-jrspd-40dc-series-solar-pv-dc-surge-protective-device\/","title":{"rendered":"\u0e88\u0eb9\u0e97\u0ea3\u0eb4\u0ead\u0ead\u0e99 JRSPD-40DC \u0e8a\u0eb8\u0e94\u0ec0\u0e84\u0eb7\u0ec8\u0ead\u0e87\u0e9b\u0ec9\u0ead\u0e87\u0e81\u0eb1\u0e99\u0ec1\u0eae\u0e87\u0e94\u0eb1\u0e99\u0e81\u0eb0\u0ec2\u0e94\u0e94\u0e81\u0eb0\u0ec1\u0eaa\u0e95\u0ebb\u0e87\u0e9e\u0eb0\u0ea5\u0eb1\u0e87\u0e87\u0eb2\u0e99\u0ec1\u0eaa\u0e87\u0ead\u0eb2\u0e97\u0eb4\u0e94 (\u0e9b\u0eb0\u0ec0\u0e9e\u0e94 2 \u0ec1\u0ea5\u0eb0 1+2)"},"content":{"rendered":"<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/2AFF7E6F-377A-45AE-BBEB-0878FDA02CFA-1024x1024.png\" alt=\"\" class=\"wp-image-1451\" style=\"width:387px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/2AFF7E6F-377A-45AE-BBEB-0878FDA02CFA-1024x1024.png 1024w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/2AFF7E6F-377A-45AE-BBEB-0878FDA02CFA-300x300.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/2AFF7E6F-377A-45AE-BBEB-0878FDA02CFA-150x150.png 150w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/2AFF7E6F-377A-45AE-BBEB-0878FDA02CFA-768x768.png 768w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/2AFF7E6F-377A-45AE-BBEB-0878FDA02CFA.png 1254w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color has-large-font-size wp-elements-1\">JUTRION JRSPD-40DC Series Solar PV DC Surge Protective Device \uff08Type 2 &amp; Type 1+2\uff09<\/h1>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">The <strong>JUTRION JRSPD-40DC Series<\/strong> is a heavy-duty, professional-grade DC Surge Protective Device (SPD) specifically engineered to safeguard solar photovoltaic (PV) systems, DC combiners, central inverters, and energy storage systems against transient overvoltages and indirect\/direct lightning strikes.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">With options covering both standard <strong>\u0e9b\u0eb0\u0ec0\u0e9e\u0e94 2<\/strong> configurations and high-risk <strong>\u0e9b\u0eb0\u0ec0\u0e9e\u0e94 1+2<\/strong> combined environments, this series provides robust, long-term defense for modern renewable energy infrastructures up to <strong>1500VDC<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-1169\"><a class=\"wp-block-button__link wp-element-button\"><strong>\u0e95\u0eb4\u0e94\u0e95\u0ecd\u0ec8\u0e9e\u0ea7\u0e81\u0ec0\u0eae\u0ebb\u0eb2<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Surge Protection Applications in Solar Photovoltaic Systems<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In rooftop PV systems, ground-mounted PV power plants, and commercial solar projects, when a surge voltage occurs, the DC SPD can respond quickly and safely discharge the surge current to the grounding system. It is usually installed in PV combiner boxes, inverter DC input terminals, and DC distribution cabinets.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>\u0e84\u0eb8\u0e99\u0eaa\u0ebb\u0ea1\u0e9a\u0eb1\u0e94\u0eab\u0ebc\u0eb1\u0e81<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>The product uses high-energy MOV (Metal Oxide Varistor) technology, with a response time of &lt; 25ns.<\/li>\n\n\n\n<li>Available in 600V, 1000V, 1500V, and 2000V DC configurations to meet different voltage application requirements.<\/li>\n\n\n\n<li>Standard 35mm DIN rail mounting design allows quick installation in PV combiner boxes and inverter enclosures.<\/li>\n\n\n\n<li>Designed to operate safely under extreme temperature conditions from -40\u00b0C to +70\u00b0C. The housing uses UL94 V-0 flame-retardant material, with an IP20 protection rating<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u0e84\u0eb3\u0e96\u0eb2\u0ea1\u0e97\u0eb5\u0ec8\u0e9e\u0ebb\u0e9a\u0ec0\u0ea5\u0eb7\u0ec9\u0ead\u0e8d<\/strong><\/h3>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Q: How is a DC surge protective device installed and wired?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong>&nbsp;A DC SPD is usually connected in parallel between PV+, PV-, and PE on the PV DC side.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Q: What is the main function of a PV DC surge protective device?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong>&nbsp;It is installed in combiner boxes or on the inverter DC side to absorb lightning surges and switching overvoltages, helping protect PV modules and inverters and reduce the risk of damage.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Q: How does a DC surge protective device protect the circuit?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong>&nbsp;Under normal conditions, PV+ and PV- supply power normally, and the SPD does not operate. When the voltage suddenly rises, the SPD quickly becomes conductive. The surge current is discharged through the SPD to the PE grounding system. As a result, the overvoltage received by downstream inverters, combiner boxes, and DC equipment is reduced.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\"><strong>DC Surge Protective Device Voltage Specifications<\/strong><\/h2>\n\n\n\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong>1. Low-Voltage DC for Weak Current \/ Industrial Control \/ Communication Systems<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Common voltages in these applications:12V \/ 24V \/ 36V \/ 48V \/ 60V<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>2. Low-Voltage DC for Industrial Control \/ Energy Storage Systems<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Common voltages in these applications:72V \/ 96V \/ 110V<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>3. High-Voltage DC for Photovoltaic \/ New Energy Systems<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Common voltages in these applications:200V \/ 400V \/ 600V \/ 800V \/ 1000V \/ 1200V \/ 1500V \/ 2000V<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>4. Dedicated DC Applications for Railway \/ Power Systems<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Common voltages in these applications220V \/ 250V \/ 300V<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The above data refers to common application scenarios and operating voltage levels. In actual use, a more suitable DC surge protective device can be selected or customized according to the specific application scenario and system voltage.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-large-font-size\"><strong>JUTRION PV DC Surge Protective Device Detailed Parameters<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">JUTRION DC Surge Protective Device is specially designed and manufactured for solar photovoltaic systems. This product can be customized according to customer requirements, and suitable specifications can be recommended based on different application scenarios.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>DC SPD Wiring Diagram:<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"599\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-13-11.23.01-1024x599.png\" alt=\"\" class=\"wp-image-1596\" style=\"width:1147px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-13-11.23.01-1024x599.png 1024w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-13-11.23.01-300x175.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-13-11.23.01-768x449.png 768w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/\u622a\u5c4f2026-07-13-11.23.01.png 1173w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>DC SPD Technical Parameters<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">Application Scenario<\/th><th class=\"has-text-align-left\" data-align=\"left\">Common Voltage Uc (DC)<\/th><th class=\"has-text-align-left\" data-align=\"left\">Nominal Discharge Current In<\/th><th class=\"has-text-align-left\" data-align=\"left\">Maximum Discharge Current Imax<\/th><th class=\"has-text-align-left\" data-align=\"left\">Voltage Protection Level Up<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Low-Voltage Security Systems (Monitoring \/ Access Control \/ Communication)<\/td><td class=\"has-text-align-left\" data-align=\"left\">12V, 24V, 48V<\/td><td class=\"has-text-align-left\" data-align=\"left\">10kA, 20kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">20kA, 40kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.8\u20132.0kV<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Industrial Automation (PLC \/ Industrial Control Equipment)<\/td><td class=\"has-text-align-left\" data-align=\"left\">36V, 60V, 110V<\/td><td class=\"has-text-align-left\" data-align=\"left\">20kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">40kA, 60kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.5\u20133.0kV<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Residential PV Systems (Combiner Box \/ Inverter)<\/td><td class=\"has-text-align-left\" data-align=\"left\">600V, 1000V<\/td><td class=\"has-text-align-left\" data-align=\"left\">30kA, 40kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">60kA, 80kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.5\u20134.0kV<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Large PV Systems \/ Energy Storage<\/td><td class=\"has-text-align-left\" data-align=\"left\">1500V, 2000V<\/td><td class=\"has-text-align-left\" data-align=\"left\">40kA, 60kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">80kA, 100kA, 120kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.0\u20136.0kV<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Power \/ Railway Dedicated Applications<\/td><td class=\"has-text-align-left\" data-align=\"left\">220V, 250V, 300V<\/td><td class=\"has-text-align-left\" data-align=\"left\">30kA, 40kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">60kA, 80kA<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.0\u20134.0kV<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>DC SPD Dimensions<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"692\" height=\"395\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/875DA3B6-BD49-49DB-B1DA-EBDB7FD89E0A.png\" alt=\"\" class=\"wp-image-1597\" style=\"width:1147px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/875DA3B6-BD49-49DB-B1DA-EBDB7FD89E0A.png 692w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/875DA3B6-BD49-49DB-B1DA-EBDB7FD89E0A-300x171.png 300w\" sizes=\"auto, (max-width: 692px) 100vw, 692px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-group has-palette-color-9-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center has-palette-color-8-color has-text-color has-link-color has-large-font-size wp-elements-2 wp-block-paragraph\"><strong>\u0e95\u0eb4\u0e94\u0e95\u0ecd\u0ec8\u0e9e\u0ea7\u0e81\u0ec0\u0eae\u0ebb\u0eb2\u0ec0\u0e9e\u0eb7\u0ec8\u0ead\u0e81\u0eb2\u0e99\u0eaa\u0eb0\u0edc\u0eb1\u0e9a\u0eaa\u0eb0\u0edc\u0eb9\u0e99\u0e97\u0eb2\u0e87\u0ec0\u0e95\u0eb1\u0e81\u0e99\u0eb4\u0e81\u0ea1\u0eb7\u0ead\u0eb2\u0e8a\u0eb5\u0e9a<br>\u0ec3\u0eab\u0ec9\u0e9e\u0ea7\u0e81\u0ec0\u0eae\u0ebb\u0eb2\u0e81\u0eb2\u0e8d\u0ec0\u0e9b\u0eb1\u0e99\u0e84\u0eb9\u0ec8\u0eae\u0ec8\u0ea7\u0ea1\u0e87\u0eb2\u0e99\u0e97\u0eb5\u0ec8\u0ec0\u0ea5\u0eb4\u0e81\u0ec0\u0e8a\u0eb4\u0ec8\u0e87<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\"><strong>\u0e95\u0eb4\u0e94\u0e95\u0ecd\u0ec8\u0e9e\u0ea7\u0e81\u0ec0\u0eae\u0ebb\u0eb2<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>JUTRION JRSPD-40DC Series Solar PV DC Surge Protective Device \uff08Type 2 &amp; Type 1+2\uff09 The JUTRION JRSPD-40DC Series is a heavy-duty, professional-grade DC Surge Protective Device (SPD) specifically engineered to safeguard solar photovoltaic (PV) systems, DC combiners, central inverters, and energy storage systems against transient overvoltages and indirect\/direct lightning strikes. With options covering both standard [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":735,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1595","page","type-page","status-publish","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/jutrion.com\/lo\/wp-json\/wp\/v2\/pages\/1595","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jutrion.com\/lo\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jutrion.com\/lo\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jutrion.com\/lo\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jutrion.com\/lo\/wp-json\/wp\/v2\/comments?post=1595"}],"version-history":[{"count":4,"href":"https:\/\/jutrion.com\/lo\/wp-json\/wp\/v2\/pages\/1595\/revisions"}],"predecessor-version":[{"id":1607,"href":"https:\/\/jutrion.com\/lo\/wp-json\/wp\/v2\/pages\/1595\/revisions\/1607"}],"up":[{"embeddable":true,"href":"https:\/\/jutrion.com\/lo\/wp-json\/wp\/v2\/pages\/735"}],"wp:attachment":[{"href":"https:\/\/jutrion.com\/lo\/wp-json\/wp\/v2\/media?parent=1595"}],"curies":[{"name":"\u0ea7\u0e9e","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}