{"id":1770,"date":"2026-07-25T15:55:49","date_gmt":"2026-07-25T07:55:49","guid":{"rendered":"https:\/\/jutrion.com\/?page_id=1770"},"modified":"2026-07-25T16:20:59","modified_gmt":"2026-07-25T08:20:59","slug":"juq5-pc-class-automatic-transfer-switch","status":"publish","type":"page","link":"https:\/\/jutrion.com\/pt\/products\/juq5-pc-class-automatic-transfer-switch\/","title":{"rendered":"Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ5"},"content":{"rendered":"<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-1\">Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ5<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">O Interruptor de Transfer\u00eancia Autom\u00e1tica da S\u00e9rie JUQ5 Classe PC \u00e9 projetado para AC 50\/60 Hz, AC 400 V, e corrente nominal de at\u00e9 800 A. Ele transfere automaticamente a carga entre as fontes de energia normal e reserva quando ocorre falha de energia, subtens\u00e3o, sobretens\u00e3o ou perda de fase. O interruptor suporta opera\u00e7\u00e3o autom\u00e1tica e manual e apresenta posi\u00e7\u00f5es I-0-II com intertravamento confi\u00e1vel.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\"><strong>Padr\u00e3o: IEC 60947-6-1<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-7b4500cd wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-1169\"><a class=\"wp-block-button__link has-palette-color-9-color has-text-color has-link-color wp-element-button\"><strong>OBTENHA SEU OR\u00c7AMENTO<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-1024x768.png\" alt=\"\" class=\"wp-image-1256\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-1024x768.png 1024w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-300x225.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863-768x576.png 768w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/6D818B16-409E-42B8-A03E-3D23A9815863.png 1448w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-3\"><strong>Principais Caracter\u00edsticas do Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ5<\/strong><\/h2>\n<\/blockquote>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong>Design Verdadeiro Classe PC<\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mecanismo de transfer\u00eancia dedicado para comuta\u00e7\u00e3o confi\u00e1vel.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Comuta\u00e7\u00e3o de Tr\u00eas Posi\u00e7\u00f5es I-O-II<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Posi\u00e7\u00f5es Normal, Desligado e Reserva com intertravamento mec\u00e2nico.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Opera\u00e7\u00e3o Autom\u00e1tica e Manual<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Suporta transfer\u00eancia autom\u00e1tica e controle manual.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Monitoramento da Fonte de Energia<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Monitora as fontes de energia normal e de reserva.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Ampla Faixa de Corrente<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dispon\u00edvel de 16A a 800A com op\u00e7\u00f5es de 2P, 3P e 4P.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Longa Vida \u00datil<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Contatos e mecanismo dur\u00e1veis para opera\u00e7\u00e3o confi\u00e1vel.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-4\"><strong>Vis\u00e3o Geral dos Componentes do JUQ5<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Explore os principais componentes e controles operacionais do Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ5, incluindo terminais de energia, indicadores de posi\u00e7\u00e3o, terminais de controle e recursos de opera\u00e7\u00e3o manual.<\/strong><\/p>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"853\" height=\"569\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure.png\" alt=\"\" class=\"wp-image-1771\" style=\"width:687px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure.png 853w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure-300x200.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/juq5-pc-class-automatic-transfer-switch-product-structure-768x512.png 768w\" sizes=\"auto, (max-width: 853px) 100vw, 853px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-5\"><strong>Especifica\u00e7\u00f5es T\u00e9cnicas<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Par\u00e2metro<\/strong><\/th><th><strong>Especifica\u00e7\u00e3o<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Modelo do Produto<\/td><td>Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ5<\/td><\/tr><tr><td>Classe do Produto<\/td><td>Classe PC<\/td><\/tr><tr><td>Corrente Nominal (In)<\/td><td>16A\u2013800A<\/td><\/tr><tr><td>N\u00famero de Polos<\/td><td>2P \/ 3P \/ 4P<\/td><\/tr><tr><td>Tens\u00e3o Operacional Nominal (Ue)<\/td><td>AC 230V \/ 400V<\/td><\/tr><tr><td>Frequ\u00eancia Nominal<\/td><td>50\/60Hz<\/td><\/tr><tr><td>Tens\u00e3o de Isolamento Nominal (Ui)<\/td><td>AC 690V<\/td><\/tr><tr><td>Tens\u00e3o de Suportabilidade a Impulso Nominal (Uimp)<\/td><td>8kV<\/td><\/tr><tr><td>Categoria de Utiliza\u00e7\u00e3o<\/td><td>AC-33iB<\/td><\/tr><tr><td>Posi\u00e7\u00f5es de Comuta\u00e7\u00e3o<\/td><td>I\u2013O\u2013II<\/td><\/tr><tr><td>Modo de Opera\u00e7\u00e3o<\/td><td>Autom\u00e1tico \/ Manual<\/td><\/tr><tr><td>Tempo de Transfer\u00eancia<\/td><td>\u22641,3s<\/td><\/tr><tr><td>Tempo de Transfer\u00eancia de Contato<\/td><td>\u22640,6s<\/td><\/tr><tr><td>Intertravamento Mec\u00e2nico<\/td><td>Sim<\/td><\/tr><tr><td>Fun\u00e7\u00e3o de Isolamento<\/td><td>Sim<\/td><\/tr><tr><td>M\u00e9todo de Fia\u00e7\u00e3o<\/td><td>Conex\u00e3o Frontal<\/td><\/tr><tr><td>M\u00e9todo de montagem<\/td><td>Instala\u00e7\u00e3o Vertical Fixa<\/td><\/tr><tr><td>Grau de Prote\u00e7\u00e3o<\/td><td>IP20<\/td><\/tr><tr><td>Temperatura Ambiente de Opera\u00e7\u00e3o<\/td><td>-5\u00b0C a +40\u00b0C<\/td><\/tr><tr><td>Altitude<\/td><td>\u22642000m<\/td><\/tr><tr><td>Norma Aplic\u00e1vel<\/td><td>IEC 60947-6-1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-6 wp-block-paragraph\"><strong>AS ESPECIFICA\u00c7\u00d5ES T\u00c9CNICAS PODEM VARIAR DEPENDENDO DO TAMANHO DA ESTRUTURA, CONFIGURA\u00c7\u00c3O DO POLO E TIPO DE CONTROLADOR. ENTRE EM CONTATO COM A JUTRION PARA SELE\u00c7\u00c3O DETALHADA DO MODELO.<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-7\"><strong><strong>Corrente Nominal<\/strong><\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Modelo<\/strong><\/th><th><strong>Corrente Nominal<\/strong><\/th><\/tr><\/thead><tbody><tr><td>JUQ5-63<\/td><td>16A, 20A, 25A, 32A, 40A, 50A, 63A<\/td><\/tr><tr><td>JUQ5-80<\/td><td>63A, 80A<\/td><\/tr><tr><td>JUQ5-125<\/td><td>63A, 80A, 100A, 125A<\/td><\/tr><tr><td>JUQ5-225<\/td><td>100A, 125A, 160A, 180A, 200A, 225A<\/td><\/tr><tr><td>JUQ5-250<\/td><td>100A, 125A, 160A, 180A, 200A, 225A, 250A<\/td><\/tr><tr><td>JUQ5-400<\/td><td>250A, 315A, 350A, 400A<\/td><\/tr><tr><td>JUQ5-630<\/td><td>400A, 500A, 630A<\/td><\/tr><tr><td>JUQ5-800<\/td><td>630A, 700A, 800A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-8\"><strong>Aplica\u00e7\u00f5es<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Edif\u00edcios Comerciais<\/strong><br>Adequado para edif\u00edcios de escrit\u00f3rios, centros comerciais, hot\u00e9is e outras instala\u00e7\u00f5es comerciais que exigem transfer\u00eancia de energia confi\u00e1vel.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Instala\u00e7\u00f5es Industriais<\/strong><br>Projetado para f\u00e1bricas, oficinas, linhas de produ\u00e7\u00e3o e sistemas de distribui\u00e7\u00e3o de energia industrial.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Sistemas de Backup com Gerador<\/strong><br>Transfere automaticamente a carga para um gerador de reserva quando o fornecimento normal de energia falha.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Data Centers e Salas de Comunica\u00e7\u00e3o<\/strong><br>Ajuda a manter energia cont\u00ednua para servidores, equipamentos de rede e sistemas de comunica\u00e7\u00e3o.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Hospitais e Instala\u00e7\u00f5es P\u00fablicas<\/strong><br>Adequado para cargas el\u00e9tricas importantes onde a continuidade de energia e a confiabilidade operacional s\u00e3o necess\u00e1rias.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Edif\u00edcios Residenciais e de Uso Misto<\/strong><br>Ideal para apartamentos, villas, edif\u00edcios residenciais e instala\u00e7\u00f5es de uso misto equipadas com sistemas de energia de backup.<\/p>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-9\"><strong>Conformidade e Normas<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">O Comutador de Transfer\u00eancia Autom\u00e1tica JUQ5 Classe PC \u00e9 projetado e fabricado de acordo com normas internacionais relevantes para equipamentos el\u00e9tricos de baixa tens\u00e3o, ajudando a garantir opera\u00e7\u00e3o segura, transfer\u00eancia de energia confi\u00e1vel e desempenho de longo prazo.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>IEC 60947-6-1<\/strong> \u2013 Aparelhagem de baixa tens\u00e3o e equipamentos de controle \u2013 Equipamentos de comuta\u00e7\u00e3o de transfer\u00eancia<\/li>\n\n\n\n<li><strong>IEC 60947-1<\/strong> \u2013 Aparelhagem de baixa tens\u00e3o e equipamentos de controle \u2013 Regras gerais<\/li>\n\n\n\n<li><strong>IEC 60664<\/strong> \u2013 Coordena\u00e7\u00e3o de isolamento para equipamentos em sistemas de baixa tens\u00e3o<\/li>\n\n\n\n<li><strong>Requisitos CE<\/strong> \u2013 Projetado para atender aos requisitos europeus aplic\u00e1veis para equipamentos el\u00e9tricos de baixa tens\u00e3o<\/li>\n\n\n\n<li><strong>Requisitos RoHS<\/strong> \u2013 Em conformidade com restri\u00e7\u00f5es de subst\u00e2ncias perigosas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Documentos de certifica\u00e7\u00e3o e conformidade podem variar conforme o modelo do produto e requisitos do pedido. Entre em contato com a JUTRION para confirma\u00e7\u00e3o.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-10\"><strong>Por Que Escolher o ATS JUQ5 da JUTRION?<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-11 is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Mecanismo de Transfer\u00eancia Dedicado Classe PC<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>O JUQ5 utiliza um mecanismo de transfer\u00eancia dedicado Classe PC projetado especificamente para comuta\u00e7\u00e3o entre duas fontes de energia. Ele n\u00e3o depende de um mecanismo de disjuntor para completar a transfer\u00eancia, tornando-o adequado para sistemas de distribui\u00e7\u00e3o de energia que exigem comuta\u00e7\u00e3o de fonte confi\u00e1vel e est\u00e1vel.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Teste Funcional Antes do Envio<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Cada unidade JUQ5 passa por inspe\u00e7\u00f5es de opera\u00e7\u00e3o mec\u00e2nica, fun\u00e7\u00e3o de transfer\u00eancia e desempenho el\u00e9trico b\u00e1sico antes do envio para ajudar a reduzir o risco de problemas de instala\u00e7\u00e3o e opera\u00e7\u00e3o.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Servi\u00e7os flex\u00edveis de OEM e ODM<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>Personaliza\u00e7\u00e3o de marca, placas de identifica\u00e7\u00e3o do produto, embalagens, etiquetas, manuais e configura\u00e7\u00f5es de controle selecionadas est\u00e3o dispon\u00edveis para distribuidores, montadores de pain\u00e9is e clientes OEM.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Suporte \u00e0 Sele\u00e7\u00e3o T\u00e9cnica<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">A JUTRION pode auxiliar os clientes na sele\u00e7\u00e3o do ATS adequado conforme a tens\u00e3o do sistema, corrente nominal, n\u00famero de polos, fonte de energia de reserva e requisitos da aplica\u00e7\u00e3o.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Documenta\u00e7\u00e3o T\u00e9cnica Completa<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Folhetos t\u00e9cnicos do produto, desenhos dimensionais, instru\u00e7\u00f5es de instala\u00e7\u00e3o, imagens do produto e outros materiais t\u00e9cnicos est\u00e3o dispon\u00edveis para apoiar o projeto, instala\u00e7\u00e3o e promo\u00e7\u00e3o do produto.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Fornecimento Est\u00e1vel em Grande Escala<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Com uma faixa de corrente nominal de 16A a 800A, a s\u00e9rie JUQ5 \u00e9 adequada para projetos de distribui\u00e7\u00e3o, integra\u00e7\u00e3o de equipamentos e compras em grande volume.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-12\"><strong>Perguntas Frequentes<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>O que \u00e9 um Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Um Interruptor de Transfer\u00eancia Autom\u00e1tica (ATS) Classe PC \u00e9 um dispositivo de comuta\u00e7\u00e3o projetado especificamente para transferir cargas el\u00e9tricas entre a fonte de energia normal e a fonte de energia de reserva. Destina-se a uma transfer\u00eancia confi\u00e1vel de energia e n\u00e3o oferece prote\u00e7\u00e3o contra sobrecarga ou curto-circuito. Disjuntores ou fus\u00edveis apropriados devem ser instalados a montante para prote\u00e7\u00e3o do sistema.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Como escolher a corrente nominal correta do ATS?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">A corrente nominal do ATS deve ser igual ou superior \u00e0 corrente m\u00e1xima de opera\u00e7\u00e3o da carga conectada. O tipo de carga, corrente de partida do motor, temperatura ambiente e expans\u00e3o futura de capacidade tamb\u00e9m devem ser considerados para garantir opera\u00e7\u00e3o segura e confi\u00e1vel.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>O ATS JUQ5 pode funcionar com um gerador a diesel?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Sim. O Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ5 \u00e9 adequado para aplica\u00e7\u00f5es que requerem transfer\u00eancia autom\u00e1tica entre a rede el\u00e9trica e um gerador a diesel. \u00c9 amplamente utilizado em edif\u00edcios comerciais, instala\u00e7\u00f5es industriais, hospitais, data centers e outros sistemas de energia de reserva.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Qual a diferen\u00e7a entre um ATS Classe PC e um ATS Classe CB?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Um ATS Classe PC utiliza um mecanismo de comuta\u00e7\u00e3o dedicado especificamente projetado para transferir energia entre duas fontes, enquanto um ATS Classe CB \u00e9 tipicamente constru\u00eddo com disjuntores e tamb\u00e9m pode fornecer prote\u00e7\u00e3o contra sobrecarga e curto-circuito. As unidades ATS Classe PC s\u00e3o geralmente mais compactas e otimizadas para transfer\u00eancia de energia confi\u00e1vel.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>A JUTRION oferece servi\u00e7os OEM e ODM?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Sim. A JUTRION oferece servi\u00e7os flex\u00edveis OEM e ODM, incluindo personaliza\u00e7\u00e3o de marca, etiquetas de produto, embalagens, manuais do usu\u00e1rio, documenta\u00e7\u00e3o t\u00e9cnica e outras solu\u00e7\u00f5es sob medida para atender \u00e0s necessidades de distribuidores, montadores de pain\u00e9is, fabricantes OEM e clientes de projetos em todo o mundo.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Por que escolher a JUTRION como seu fornecedor de ATS?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">A JUTRION \u00e9 especializada em produtos el\u00e9tricos de baixa tens\u00e3o para mercados globais. Estamos comprometidos em fornecer qualidade confi\u00e1vel, suporte t\u00e9cnico profissional, personaliza\u00e7\u00e3o flex\u00edvel, capacidade de produ\u00e7\u00e3o est\u00e1vel e atendimento ao cliente \u00e1gil para ajudar os clientes a construir sistemas de distribui\u00e7\u00e3o de energia seguros e confi\u00e1veis.<\/p>\n\n\n\n<div class=\"wp-block-group alignfull has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-13 is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>FALE COM NOSSOS ESPECIALISTAS EM ATS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Basta nos informar sua corrente nominal, tens\u00e3o do sistema, configura\u00e7\u00e3o de polos, fonte de energia de reserva e requisitos da aplica\u00e7\u00e3o. Nossos engenheiros recomendar\u00e3o o Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ5 mais adequado para seu projeto.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 popmake-1169\"><a class=\"wp-block-button__link wp-element-button\"><strong>Entre em Contato com a JUTRION Hoje<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>JUQ5 PC Class Automatic Transfer Switch The JUQ5 Series PC Class Automatic Transfer Switch is designed for AC 50\/60 Hz, AC 400 V, and rated current up to 800 A. It automatically transfers the load between the normal and standby power sources when a power failure, undervoltage, overvoltage, or phase loss occurs. The switch supports [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":735,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1770","page","type-page","status-publish","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages\/1770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/comments?post=1770"}],"version-history":[{"count":2,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages\/1770\/revisions"}],"predecessor-version":[{"id":2004,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages\/1770\/revisions\/2004"}],"up":[{"embeddable":true,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages\/735"}],"wp:attachment":[{"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/media?parent=1770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}