{"id":1773,"date":"2026-08-28T17:11:23","date_gmt":"2026-08-28T09:11:23","guid":{"rendered":"https:\/\/jutrion.com\/?page_id=1773"},"modified":"2026-08-28T17:11:57","modified_gmt":"2026-08-28T09:11:57","slug":"juq1-pc-class-automatic-transfer-switch","status":"publish","type":"page","link":"https:\/\/jutrion.com\/pt\/products\/juq1-pc-class-automatic-transfer-switch\/","title":{"rendered":"Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ1"},"content":{"rendered":"<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-1\">Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ1<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">A S\u00e9rie JUQ1 \u00e9 um Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC do tipo isolamento projetado para sistemas de distribui\u00e7\u00e3o de energia dupla de alta capacidade. Com correntes nominais de 16A a 3200A e posi\u00e7\u00f5es de comuta\u00e7\u00e3o I-O-II est\u00e1veis, combina transfer\u00eancia de energia e isolamento de carga em uma unidade integrada.<\/p>\n\n\n\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\"><strong>Padr\u00e3o: IEC 60947-6-1<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-7b4500cd wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-1169\"><a class=\"wp-block-button__link has-palette-color-9-color has-text-color has-link-color wp-element-button\"><strong>OBTENHA SEU OR\u00c7AMENTO<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-1024x768.png\" alt=\"\" class=\"wp-image-1258\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-1024x768.png 1024w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-300x225.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815-768x576.png 768w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/06\/3815.png 1448w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-3\"><strong><strong>Principais Caracter\u00edsticas do Interruptor de Transfer\u00eancia Autom\u00e1tica JUQ1<\/strong><\/strong><\/h2>\n<\/blockquote>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Estrutura de Comuta\u00e7\u00e3o do Tipo Isolamento<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Combina fun\u00e7\u00f5es de transfer\u00eancia autom\u00e1tica de energia e isolamento de carga em uma unidade de comuta\u00e7\u00e3o integrada.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Faixa de Corrente de 16A\u20133200A<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cobre uma ampla gama de capacidades de distribui\u00e7\u00e3o, desde quadros de distribui\u00e7\u00e3o padr\u00e3o at\u00e9 grandes sistemas de energia industrial.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>Posi\u00e7\u00f5es I-O-II Est\u00e1veis<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fornece posi\u00e7\u00f5es de energia normal, DESLIGADO e energia de reserva para comuta\u00e7\u00e3o confi\u00e1vel e isolamento vis\u00edvel do circuito.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>M\u00faltiplos Modos de Opera\u00e7\u00e3o<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Suporta opera\u00e7\u00e3o autom\u00e1tica, controle el\u00e9trico remoto, opera\u00e7\u00e3o manual de emerg\u00eancia e comuta\u00e7\u00e3o manual.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong><strong>Intertravamento Mec\u00e2nico e El\u00e9trico<\/strong><\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mecanismos de intertravamento independentes impedem que as fontes de energia normal e de reserva sejam conectadas simultaneamente.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong><strong>Op\u00e7\u00f5es de 3 Polos e 4 Polos<\/strong><\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dispon\u00edvel em configura\u00e7\u00f5es 3P e 4P para diferentes sistemas de distribui\u00e7\u00e3o de energia de baixa tens\u00e3o.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-4\"><strong>Vis\u00e3o Geral dos Componentes do JUQ1<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Explore os principais componentes e controles operacionais do Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ1, incluindo terminais de energia, indicadores de posi\u00e7\u00e3o da fonte, terminais de controle, trava el\u00e9trica e recursos de opera\u00e7\u00e3o manual de emerg\u00eancia.<\/strong><\/p>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"943\" height=\"550\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5.png\" alt=\"\" class=\"wp-image-2005\" style=\"aspect-ratio:1.7145809772647507;width:1300px;height:auto\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5.png 943w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5-300x175.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/08\/3451e833-46e4-4c1a-b609-11b13e771df5-768x448.png 768w\" sizes=\"auto, (max-width: 943px) 100vw, 943px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-5\"><strong>Especifica\u00e7\u00f5es T\u00e9cnicas<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Par\u00e2metro<\/th><th>Especifica\u00e7\u00f5es do JUQ1<\/th><\/tr><\/thead><tbody><tr><td>Tipo de Produto<\/td><td>Interruptor de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ1<\/td><\/tr><tr><td>Corrente Nominal<\/td><td>16 A\u20133200 A<\/td><\/tr><tr><td>N\u00famero de Polos<\/td><td>3P, 4P<\/td><\/tr><tr><td>Tens\u00e3o Operacional Nominal<\/td><td>AC 400 V<\/td><\/tr><tr><td>Frequ\u00eancia Nominal<\/td><td>50 Hz<\/td><\/tr><tr><td>Tens\u00e3o de Controle<\/td><td>Padr\u00e3o AC 220 V; op\u00e7\u00f5es DC 24 V, DC 48 V ou DC 110 V<\/td><\/tr><tr><td>Posi\u00e7\u00f5es de Comuta\u00e7\u00e3o<\/td><td>I\u20130\u2013II<\/td><\/tr><tr><td>Modos de Opera\u00e7\u00e3o<\/td><td>Opera\u00e7\u00e3o autom\u00e1tica, remota motorizada e manual de emerg\u00eancia<\/td><\/tr><tr><td>Modos de Transfer\u00eancia<\/td><td>Rede para rede, rede para gerador, transfer\u00eancia autom\u00e1tica com retorno autom\u00e1tico<\/td><\/tr><tr><td>Categoria de Utiliza\u00e7\u00e3o<\/td><td>AC-31A \/ AC-33A \/ AC-35A, dependendo da corrente nominal<\/td><\/tr><tr><td>Tens\u00e3o Nominal de Suportabilidade a Impulso<\/td><td>8 kV ou 12 kV, dependendo do tamanho da estrutura<\/td><\/tr><tr><td>Tempo de Transfer\u00eancia<\/td><td>Aproximadamente 0,45\u20131,2 s, dependendo do tamanho da estrutura<\/td><\/tr><tr><td>Configura\u00e7\u00e3o de Polos<\/td><td>3P \/ 4P<\/td><\/tr><tr><td>Classe ATSE<\/td><td>Classe PC<\/td><\/tr><tr><td>Norma Aplic\u00e1vel<\/td><td>IEC 60947-6-1 \/ GB\/T 14048.11<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-6 wp-block-paragraph\"><strong>AS ESPECIFICA\u00c7\u00d5ES T\u00c9CNICAS VARIAM CONFORME O TAMANHO DA ESTRUTURA, CORRENTE NOMINAL, CONFIGURA\u00c7\u00c3O DE POLOS E TIPO DE CONTROLE. ENTRE EM CONTATO COM A JUTRION PARA CONFIRMAR O MODELO EXATO DO JUQ1 E A CONFIGURA\u00c7\u00c3O DO PROJETO.<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-7\"><strong><strong>Corrente Nominal<\/strong><\/strong><\/h2>\n<\/blockquote>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Estrutura JUQ1<\/th><th>Corrente Nominal Dispon\u00edvel<\/th><\/tr><\/thead><tbody><tr><td>Estrutura JUQ1-100<\/td><td>20A, 32A, 40A, 63A, 80A, 100A<\/td><\/tr><tr><td>Estrutura JUQ1-160<\/td><td>125A, 160A<\/td><\/tr><tr><td>Estrutura JUQ1-250<\/td><td>200A, 225A, 250A<\/td><\/tr><tr><td>Estrutura JUQ1-400<\/td><td>315A, 400A<\/td><\/tr><tr><td>Estrutura JUQ1-630<\/td><td>500A, 630A<\/td><\/tr><tr><td>Estrutura JUQ1-1000<\/td><td>800A, 1000A<\/td><\/tr><tr><td>Estrutura JUQ1-1250<\/td><td>1250A<\/td><\/tr><tr><td>Estrutura JUQ1-1600<\/td><td>1600A<\/td><\/tr><tr><td>Estrutura JUQ1-2000<\/td><td>2000A<\/td><\/tr><tr><td>Estrutura JUQ1-2500<\/td><td>2500A<\/td><\/tr><tr><td>Estrutura JUQ1-3200<\/td><td>3200A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-8\"><strong>Aplica\u00e7\u00f5es<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Edif\u00edcios Comerciais<\/strong><br>Fornece transfer\u00eancia autom\u00e1tica entre fontes de alimenta\u00e7\u00e3o normal e de reserva para edif\u00edcios de escrit\u00f3rios, centros comerciais, hot\u00e9is e outros sistemas de distribui\u00e7\u00e3o comercial.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Instala\u00e7\u00f5es Industriais<\/strong><br>Adequado para f\u00e1bricas, oficinas, linhas de produ\u00e7\u00e3o e sistemas de distribui\u00e7\u00e3o industrial que exigem transfer\u00eancia confi\u00e1vel entre duas fontes de alimenta\u00e7\u00e3o.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Sistemas de Backup com Gerador<\/strong><br>Suporta transfer\u00eancia da concession\u00e1ria para o gerador e retorno autom\u00e1tico quando a alimenta\u00e7\u00e3o normal \u00e9 restaurada, dependendo da configura\u00e7\u00e3o do controlador selecionado.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Data Centers e Salas de Comunica\u00e7\u00e3o<\/strong><br>Fornece funcionalidade de transfer\u00eancia de fonte para data centers, salas de comunica\u00e7\u00e3o, instala\u00e7\u00f5es de telecomunica\u00e7\u00f5es e outras instala\u00e7\u00f5es que exigem continuidade de energia confi\u00e1vel.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Hospitais e Instala\u00e7\u00f5es P\u00fablicas<\/strong><br>Adequado para hospitais, edif\u00edcios p\u00fablicos e projetos de infraestrutura onde sistemas de distribui\u00e7\u00e3o essenciais exigem uma fonte de alimenta\u00e7\u00e3o alternativa.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Sistemas de Distribui\u00e7\u00e3o Principal<\/strong><br>Dispon\u00edvel em classifica\u00e7\u00f5es de corrente de at\u00e9 3200A para quadros de distribui\u00e7\u00e3o principal e outras aplica\u00e7\u00f5es de transfer\u00eancia de energia normal e de reserva de alta corrente.<\/p>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-9\"><strong>Conformidade e Normas<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">O Comutador de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ1 \u00e9 projetado para aplica\u00e7\u00f5es de transfer\u00eancia de energia normal e de reserva de baixa tens\u00e3o. O design do produto faz refer\u00eancia aos requisitos aplic\u00e1veis para equipamentos de comuta\u00e7\u00e3o de transfer\u00eancia, conjuntos de manobra e controle de baixa tens\u00e3o e interruptores-seccionadores.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>IEC 60947-6-1<\/strong> \u2013 Aparelhagem de baixa tens\u00e3o e equipamentos de controle \u2013 Equipamentos de comuta\u00e7\u00e3o de transfer\u00eancia<\/li>\n\n\n\n<li><strong>IEC 60947-1<\/strong> \u2013 Aparelhagem de baixa tens\u00e3o e equipamentos de controle \u2013 Regras gerais<\/li>\n\n\n\n<li><strong>IEC 60664<\/strong> \u2013 Coordena\u00e7\u00e3o de isolamento para equipamentos em sistemas de baixa tens\u00e3o<\/li>\n\n\n\n<li><strong>Requisitos CE<\/strong> \u2013 Projetado para atender aos requisitos europeus aplic\u00e1veis para equipamentos el\u00e9tricos de baixa tens\u00e3o<\/li>\n\n\n\n<li><strong>Requisitos RoHS<\/strong> \u2013 Em conformidade com restri\u00e7\u00f5es de subst\u00e2ncias perigosas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Normas aplic\u00e1veis, documentos de teste e informa\u00e7\u00f5es de conformidade podem variar conforme o modelo, classifica\u00e7\u00e3o de corrente e mercado de destino. Por favor, confirme a documenta\u00e7\u00e3o necess\u00e1ria com a JUTRION antes de fazer o pedido.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-10\"><strong>Por Que Escolher o ATS JUQ1 da JUTRION?<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-11 is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Mecanismo de Transfer\u00eancia Dedicado Classe PC<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>O JUQ1 utiliza um mecanismo de transfer\u00eancia Classe PC do tipo interruptor de carga projetado para comutar entre fontes de alimenta\u00e7\u00e3o normal e de reserva. N\u00e3o depende de dois disjuntores para completar a fun\u00e7\u00e3o de transfer\u00eancia.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Controlador L\u00f3gico Integrado<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">O mecanismo de comuta\u00e7\u00e3o e o controle l\u00f3gico s\u00e3o integrados em uma \u00fanica unidade. O controlador fornece detec\u00e7\u00e3o de fonte, comandos de transfer\u00eancia e transfer\u00eancia autom\u00e1tica com retorno autom\u00e1tico, dependendo da configura\u00e7\u00e3o selecionada.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Ampla Faixa de Corrente<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list has-small-font-size\">\n<li>A s\u00e9rie JUQ1 abrange correntes nominais de 20A a 3200A, com m\u00faltiplos tamanhos de estrutura para aplica\u00e7\u00f5es comerciais, industriais e de distribui\u00e7\u00e3o principal.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>M\u00faltiplos Modos de Opera\u00e7\u00e3o<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Suporta opera\u00e7\u00e3o autom\u00e1tica, opera\u00e7\u00e3o remota motorizada e opera\u00e7\u00e3o manual de emerg\u00eancia, permitindo que o comutador de transfer\u00eancia seja operado sob diferentes condi\u00e7\u00f5es de controle e manuten\u00e7\u00e3o.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Intertravamento El\u00e9trico e Mec\u00e2nico<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">O intertravamento el\u00e9trico e mec\u00e2nico ajuda a evitar que as fontes de alimenta\u00e7\u00e3o normal e de reserva sejam conectadas simultaneamente durante a sequ\u00eancia de transfer\u00eancia.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Op\u00e7\u00f5es de Configura\u00e7\u00e3o Flex\u00edveis<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Dispon\u00edvel em configura\u00e7\u00f5es de 3 polos e 4 polos, com controle AC 220V como padr\u00e3o e op\u00e7\u00f5es selecionadas de controle DC 24V, 48V ou 110V.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-12\"><strong>Perguntas Frequentes<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>O Que \u00c9 o Comutador de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ1?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">O JUQ1 \u00e9 um comutador de transfer\u00eancia autom\u00e1tica Classe PC projetado para transferir uma carga entre fontes de alimenta\u00e7\u00e3o normal e de reserva. Utiliza um mecanismo de transfer\u00eancia de interruptor de carga dedicado com controle l\u00f3gico integrado. Como um ATSE Classe PC, normalmente n\u00e3o fornece prote\u00e7\u00e3o contra sobrecarga ou curto-circuito, portanto, dispositivos de prote\u00e7\u00e3o coordenados s\u00e3o necess\u00e1rios no sistema de energia.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Como Escolho a Corrente Nominal Correta do JUQ1?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Selecione uma corrente nominal do JUQ1 que possa suportar a corrente mais alta esperada atrav\u00e9s do comutador de transfer\u00eancia. Verifique tamb\u00e9m a categoria de utiliza\u00e7\u00e3o, tipo de carga, corrente de partida do motor ou transformador, temperatura ambiente, condi\u00e7\u00f5es do inv\u00f3lucro, capacidade dos terminais e coordena\u00e7\u00e3o com os dispositivos de prote\u00e7\u00e3o. A corrente selecionada deve corresponder ao tamanho exato da estrutura e \u00e0 fun\u00e7\u00e3o do projeto.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>O ATS JUQ1 Pode Funcionar com um Gerador a Diesel?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Sim. O JUQ1 suporta aplica\u00e7\u00f5es de transfer\u00eancia da concession\u00e1ria para o gerador e retorno autom\u00e1tico quando o fornecimento normal \u00e9 restaurado, dependendo do controlador selecionado e da configura\u00e7\u00e3o da fia\u00e7\u00e3o. Confirme o sinal de partida do gerador, a detec\u00e7\u00e3o de tens\u00e3o e frequ\u00eancia, os atrasos de transfer\u00eancia e o arranjo de energia de controle antes de fazer o pedido.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Qual \u00c9 a Diferen\u00e7a Entre um ATS Classe PC e um ATS Classe CB?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Um ATS Classe PC utiliza um mecanismo de comuta\u00e7\u00e3o dedicado especificamente projetado para transferir energia entre duas fontes, enquanto um ATS Classe CB \u00e9 tipicamente constru\u00eddo com disjuntores e tamb\u00e9m pode fornecer prote\u00e7\u00e3o contra sobrecarga e curto-circuito. As unidades ATS Classe PC s\u00e3o geralmente mais compactas e otimizadas para transfer\u00eancia de energia confi\u00e1vel.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Devo Escolher um ATS JUQ1 de 3 Polos ou 4 Polos?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Um modelo de 3 polos comuta os tr\u00eas condutores de fase enquanto deixa o neutro n\u00e3o comutado. Um modelo de 4 polos tamb\u00e9m comuta o neutro. A decis\u00e3o depende do arranjo de aterramento do sistema, conex\u00e3o do neutro do gerador, se a fonte alternativa \u00e9 derivada separadamente e as regras de instala\u00e7\u00e3o aplic\u00e1veis.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>Quais Op\u00e7\u00f5es de Opera\u00e7\u00e3o e Controle Est\u00e3o Dispon\u00edveis?<\/strong><\/h3>\n<\/blockquote>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">O JUQ1 suporta opera\u00e7\u00e3o autom\u00e1tica, opera\u00e7\u00e3o remota motorizada e opera\u00e7\u00e3o manual de emerg\u00eancia. O controle AC 220V \u00e9 padr\u00e3o, enquanto configura\u00e7\u00f5es selecionadas podem suportar DC 24V, DC 48V ou DC 110V. Confirme o tipo de controle, configura\u00e7\u00e3o de polos, corrente nominal e modo de transfer\u00eancia necess\u00e1rio ao fazer o pedido.<\/p>\n\n\n\n<div class=\"wp-block-group alignfull has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-13 is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>FALE COM NOSSOS ESPECIALISTAS EM ATS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Basta nos informar sua corrente nominal, tens\u00e3o do sistema, configura\u00e7\u00e3o de polos, fonte de alimenta\u00e7\u00e3o de reserva e requisitos de aplica\u00e7\u00e3o. Nossos engenheiros recomendar\u00e3o o Comutador de Transfer\u00eancia Autom\u00e1tica Classe PC JUQ1 mais adequado para o seu projeto.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 popmake-1169\"><a class=\"wp-block-button__link wp-element-button\"><strong>Entre em Contato com a JUTRION Hoje<\/strong><\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>JUQ1 PC Class Automatic Transfer Switch The JUQ1 Series is an isolation-type PC Class Automatic Transfer Switch designed for high-capacity dual-power distribution systems. With rated currents from 16A to 3200A and stable I-O-II switching positions, it combines power transfer and load isolation in one integrated unit. Standard: IEC 60947-6-1 Key Features of the JUQ1 Automatic [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":735,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1773","page","type-page","status-publish","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages\/1773","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/comments?post=1773"}],"version-history":[{"count":3,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages\/1773\/revisions"}],"predecessor-version":[{"id":2006,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages\/1773\/revisions\/2006"}],"up":[{"embeddable":true,"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/pages\/735"}],"wp:attachment":[{"href":"https:\/\/jutrion.com\/pt\/wp-json\/wp\/v2\/media?parent=1773"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}