{"id":824,"date":"2026-06-09T23:10:51","date_gmt":"2026-06-09T15:10:51","guid":{"rendered":"https:\/\/jutrion.com\/?page_id=824"},"modified":"2026-07-15T13:37:13","modified_gmt":"2026-07-15T05:37:13","slug":"rcbo","status":"publish","type":"page","link":"https:\/\/jutrion.com\/tl\/rcbo\/","title":{"rendered":"RCBO"},"content":{"rendered":"<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-1\"><strong>TAGAGAWA AT TAGAPAGTUSTOS NG RCBO<\/strong><\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">Pinagsasama ng mga JUTRION RCBO ang proteksyon sa residual current, proteksyon sa overload at proteksyon sa short-circuit sa isang compact na device. Dinisenyo para sa residential, commercial at industrial distribution systems, nakakatulong ang mga ito na mapabuti ang electrical safety habang binabawasan ang installation space at wiring complexity.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe0a7de2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popmake-1169\"><a class=\"wp-block-button__link wp-element-button\"><strong>KUMUHA NG RCBO QUOTE<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"853\" height=\"569\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/BCEED11D-744B-4CDB-B87D-922CBB367097.png\" alt=\"\" class=\"wp-image-1680\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/BCEED11D-744B-4CDB-B87D-922CBB367097.png 853w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/BCEED11D-744B-4CDB-B87D-922CBB367097-300x200.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/BCEED11D-744B-4CDB-B87D-922CBB367097-768x512.png 768w\" sizes=\"auto, (max-width: 853px) 100vw, 853px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-2\"><strong>TUKLASIN ANG AMING HANAY NG PRODUKTONG RCBO<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Pumili mula sa iba't ibang pole configurations, rated currents, residual current sensitivities at breaking capacities upang matugunan ang iyong mga pangangailangan sa electrical distribution.<\/p>\n\n\n\n<div class=\"wp-block-columns has-palette-color-6-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:420px\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"523\" height=\"523\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/B153FDE4-BC13-4BCA-8FCA-FD713959ADCD.png\" alt=\"\" class=\"wp-image-1681\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/B153FDE4-BC13-4BCA-8FCA-FD713959ADCD.png 523w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/B153FDE4-BC13-4BCA-8FCA-FD713959ADCD-300x300.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/B153FDE4-BC13-4BCA-8FCA-FD713959ADCD-150x150.png 150w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong>ECO7 2-Pole Residual Current Circuit Breaker na may Overcurrent Protection<\/strong><\/h3>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Dinisenyo para sa single-phase circuits, dinidiskonekta ng ECO7 2P RCBO ang parehong live at neutral conductors habang nagbibigay ng residual current, overload at short-circuit protection.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><strong><strong>Mga Technical Parameter<\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\"><strong>Mga Pole<\/strong>\uff1a2P<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Sistemang Elektrikal<\/strong>\uff1aSingle-phase, dalawang-wire<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated na Operational Voltage Ue<\/strong>\uff1a230V AC<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Current In<\/strong>\uff1a6A\u201363A<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Residual Operating Current I\u0394n<\/strong>\uff1a10mA \/ 30mA \/ 100mA<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Uri ng Residual Current<\/strong>\uff1aType AC \/ Type A<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Instantaneous Tripping Curve<\/strong>\uff1aB \/ C<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Short-Circuit Capacity Icn<\/strong>\uff1a6kA<\/li>\n<\/ul>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Sabay na isinasara ang parehong conductors, kaya angkop ang modelong ito para sa residential socket, lighting at single-phase final circuits.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-6-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:420px\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"697\" height=\"697\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/53378D49-87CD-4E9E-A825-B896829CE25A.png\" alt=\"\" class=\"wp-image-1682\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/53378D49-87CD-4E9E-A825-B896829CE25A.png 697w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/53378D49-87CD-4E9E-A825-B896829CE25A-300x300.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/53378D49-87CD-4E9E-A825-B896829CE25A-150x150.png 150w\" sizes=\"auto, (max-width: 697px) 100vw, 697px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong>ECO7 3-Pole Residual Current Circuit Breaker na may Overcurrent Protection<\/strong><\/strong><\/h3>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Ang ECO7 3P RCBO ay nagbibigay ng integrated residual current, overload at short-circuit protection para sa three-phase circuits na walang neutral conductor.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><strong><strong>Mga Technical Parameter<\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\"><strong>Mga Pole<\/strong>\uff1a3P<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Sistemang Elektrikal<\/strong>\uff1aThree-phase, tatlong-wire<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated na Operational Voltage Ue<\/strong>\uff1a400V AC<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Current In<\/strong>\uff1a10A\u201363A<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Residual Operating Current I\u0394n<\/strong>\uff1a30mA \/ 100mA \/ 300mA<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Uri ng Residual Current<\/strong>\uff1aType AC \/ Type A<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Instantaneous Tripping Curve<\/strong>\uff1aC \/ D<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Short-Circuit Capacity Icn<\/strong>\uff1a6kA\/10KA<\/li>\n<\/ul>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Angkop para sa three-phase motors, pumps at industrial equipment na hindi nangangailangan ng neutral cond<strong>konduktor.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-6-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:420px\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"697\" height=\"697\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/3AF4AAAB-FE3D-45E2-9D82-13B8704FC531.png\" alt=\"\" class=\"wp-image-1683\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/3AF4AAAB-FE3D-45E2-9D82-13B8704FC531.png 697w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/3AF4AAAB-FE3D-45E2-9D82-13B8704FC531-300x300.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/3AF4AAAB-FE3D-45E2-9D82-13B8704FC531-150x150.png 150w\" sizes=\"auto, (max-width: 697px) 100vw, 697px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>ECO7 3P+N Residual Current Circuit Breaker na may Overcurrent Protection<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Ang ECO7 3P+N RCBO ay dinisenyo para sa three-phase four-wire systems, na nagbibigay ng coordinated protection para sa tatlong phase conductors at sa neutral conductor.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><strong><strong>Mga Technical Parameter<\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\"><strong>Mga Pole<\/strong>\uff1a3P+N<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Sistemang Elektrikal<\/strong>\uff1aThree-phase, apat na-wire<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated na Operational Voltage Ue<\/strong>\uff1a400V AC<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Current In<\/strong>\uff1a10A\u201363A<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Residual Operating Current I\u0394n<\/strong>\uff1a30mA \/ 100mA \/ 300mA<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Uri ng Residual Current<\/strong>\uff1aType A<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Instantaneous Tripping Curve<\/strong>\uff1aC<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Short-Circuit Capacity Icn<\/strong>\uff1a6kA<\/li>\n<\/ul>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Angkop para sa three-phase distribution systems na naglalaman ng parehong three-phase at single-phase loads, habang iniiwasan ang hindi kinakailangang overcurrent protection sa neutral pole.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-palette-color-6-background-color has-background is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:420px\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"697\" height=\"697\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/D0A5D381-B894-4F9A-992C-B11A0C375476.png\" alt=\"\" class=\"wp-image-1684\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/D0A5D381-B894-4F9A-992C-B11A0C375476.png 697w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/D0A5D381-B894-4F9A-992C-B11A0C375476-300x300.png 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/D0A5D381-B894-4F9A-992C-B11A0C375476-150x150.png 150w\" sizes=\"auto, (max-width: 697px) 100vw, 697px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong><strong>ECO7 4-Pole Residual Current Circuit Breaker na may Overcurrent Protection<\/strong><\/strong><\/strong><\/strong><\/h3>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Ang ECO7 4P RCBO ay nagbibigay ng simultaneous switching at protection para sa lahat ng three phase conductors at sa neutral conductor sa three-phase four-wire systems.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><strong><strong>Mga Technical Parameter<\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\"><strong>Mga Pole<\/strong>\uff1a4P<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Sistemang Elektrikal<\/strong>\uff1aThree-phase, apat na-wire<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated na Operational Voltage Ue<\/strong>\uff1a400V AC<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Current In<\/strong>\uff1a16A\u201363A<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Residual Operating Current I\u0394n<\/strong>\uff1a30mA \/ 100mA \/ 300mA<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Uri ng Residual Current<\/strong>\uff1aType A \/ Type AC<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Instantaneous Tripping Curve<\/strong>\uff1aC \/ D<\/li>\n\n\n\n<li class=\"has-small-font-size\"><strong>Rated Short-Circuit Capacity Icn<\/strong>\uff1a10kA<\/li>\n<\/ul>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Ang four-pole simultaneous disconnection ay nagbibigay ng kumpletong isolation para sa commercial buildings, industrial panels at three-phase distribution systems.<\/p>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)\">\n<h3 class=\"wp-block-heading has-palette-color-4-color has-text-color has-link-color has-x-large-font-size wp-elements-3\" style=\"margin-top:var(--wp--preset--spacing--70);margin-bottom:var(--wp--preset--spacing--70)\"><strong><strong>Mga Pangunahing Pagkakaiba sa Pagitan ng Apat na RCBO Models<\/strong><\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Modelo<\/strong><\/th><th><strong>Sistemang Elektrikal<\/strong><\/th><th><strong>Rated na Boltahe<\/strong><\/th><th><strong>Neutral na Konduktor<\/strong><\/th><th><strong>Mga Karaniwang Aplikasyon<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>ECO7 2P<\/strong><\/td><td>Sistemang single-phase, dalawang-wire<\/td><td>230V AC<\/td><td>Ang live at neutral ay sabay na isinasara<\/td><td>Mga gusaling residensyal, mga socket circuit at lighting circuit<\/td><\/tr><tr><td><strong>ECO7 3P<\/strong><\/td><td>Sistemang three-phase, tatlong-wire<\/td><td>400V AC<\/td><td>Walang neutral na konduktor<\/td><td>Mga motor, pump at kagamitang three-phase<\/td><\/tr><tr><td><strong>ECO7 3P+N<\/strong><\/td><td>Sistemang three-phase, apat na-wire<\/td><td>400V AC<\/td><td>Ang neutral ay isinasara ngunit karaniwang hindi protektado laban sa overcurrent<\/td><td>Mga sistemang may magkahalong single-phase at three-phase na load<\/td><\/tr><tr><td><strong>ECO7 4P<\/strong><\/td><td>Sistemang three-phase, apat na-wire<\/td><td>400V AC<\/td><td>Lahat ng apat na pole ay sabay na isinasara<\/td><td>Mga pangunahing sistema ng distribusyon sa komersyal at industriyal<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color has-x-large-font-size wp-elements-4 wp-block-paragraph\"><strong>Pangunahing Tampok<\/strong><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-palette-color-6-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<p class=\"wp-block-paragraph\"><strong>Integradong Proteksyon<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pinagsasama ang residual current, overload at short-circuit na proteksyon sa iisang device.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-palette-color-6-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<p class=\"wp-block-paragraph\"><strong>Maramihang Opsyon ng Pole<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Available sa mga konfigurasyong 2P, 3P, 3P+N at 4P.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-palette-color-6-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<p class=\"wp-block-paragraph\"><strong>Mabilis na Pagdiskonekta ng Fault<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mabilis na dinidiskonekta ang circuit kapag may nakitang electrical fault.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-palette-color-6-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<p class=\"wp-block-paragraph\"><strong>Pag-install sa DIN-Rail<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ang compact na modular na konstruksyon ay nagpapadali sa pag-install sa mga distribution board.<\/p>\n<\/div>\n<\/div>\n<\/blockquote>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\" style=\"margin-top:var(--wp--preset--spacing--70);margin-bottom:var(--wp--preset--spacing--70)\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-5\"><strong>MGA APLIKASYON NG RCBO<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"635\" height=\"635\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/residential_buildings_800x800.jpg\" alt=\"\" class=\"wp-image-1690 size-full\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/residential_buildings_800x800.jpg 635w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/residential_buildings_800x800-300x300.jpg 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/residential_buildings_800x800-150x150.jpg 150w\" sizes=\"auto, (max-width: 635px) 100vw, 635px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong>Mga Gusaling Residensyal<\/strong><\/h4>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Proteksyon para sa lighting, socket outlet, kusina, banyo at mga electrical circuit sa bahay.<\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"650\" height=\"650\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/commercial_buildings_800x800.jpg\" alt=\"\" class=\"wp-image-1685 size-full\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/commercial_buildings_800x800.jpg 650w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/commercial_buildings_800x800-300x300.jpg 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/commercial_buildings_800x800-150x150.jpg 150w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong><strong>Mga Gusaling Pangkomersyo<\/strong><\/strong><\/h4>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Angkop para sa mga opisina, hotel, shopping center at komersyal na sistema ng power distribution.<\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"612\" height=\"612\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/industrial_control_panels_800x800.jpg\" alt=\"\" class=\"wp-image-1687 size-full\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/industrial_control_panels_800x800.jpg 612w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/industrial_control_panels_800x800-300x300.jpg 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/industrial_control_panels_800x800-150x150.jpg 150w\" sizes=\"auto, (max-width: 612px) 100vw, 612px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong><strong>Mga Industrial Control Panel<\/strong><\/strong><\/h4>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Nagbibigay ng independiyenteng proteksyon ng circuit para sa mga kagamitang pang-industriya, makinarya at electrical load.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"608\" height=\"608\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/data_centers_800x800.jpg\" alt=\"\" class=\"wp-image-1686 size-full\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/data_centers_800x800.jpg 608w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/data_centers_800x800-300x300.jpg 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/data_centers_800x800-150x150.jpg 150w\" sizes=\"auto, (max-width: 608px) 100vw, 608px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong><strong>Mga Data Center<\/strong><\/strong><\/h4>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Pinoprotektahan ang mga indibidwal na circuit sa sensitibong sistema ng power distribution at tumutulong na mapabuti ang power continuity.<\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"698\" height=\"698\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/renewable_energy_systems_800x800.jpg\" alt=\"\" class=\"wp-image-1689 size-full\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/renewable_energy_systems_800x800.jpg 698w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/renewable_energy_systems_800x800-300x300.jpg 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/renewable_energy_systems_800x800-150x150.jpg 150w\" sizes=\"auto, (max-width: 698px) 100vw, 698px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Mga Sistema ng Renewable Energy<\/strong><\/strong><\/strong><\/h4>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Angkop para sa mga auxiliary distribution circuit sa solar, energy storage at iba pang renewable energy installation.<\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"700\" src=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/oem_distribution_boards_800x800.jpg\" alt=\"\" class=\"wp-image-1688 size-full\" srcset=\"https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/oem_distribution_boards_800x800.jpg 700w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/oem_distribution_boards_800x800-300x300.jpg 300w, https:\/\/jutrion.com\/wp-content\/uploads\/2026\/07\/oem_distribution_boards_800x800-150x150.jpg 150w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Mga OEM Distribution Board<\/strong><\/strong><\/strong><\/h4>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Maaaring isama sa mga customized na distribution board at control panel para sa iba't ibang pangangailangan ng proyekto.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-6\" style=\"margin-top:var(--wp--preset--spacing--80);margin-bottom:var(--wp--preset--spacing--80)\"><strong>BAKIT PILIIN ANG JUTRION BILANG IYONG RCBO PARTNER?<\/strong><\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-7 wp-block-paragraph\"><strong>Flexible na Serbisyong OEM at ODM<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sinusuportahan namin ang mga customized na logo, label ng produkto, packaging, rated parameter at konfigurasyon ng produkto upang matugunan ang iba't ibang pangangailangan ng merkado at proyekto.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-8 wp-block-paragraph\"><strong>Kompetitibong Pagpepresyo mula sa Pabrika<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ang direktang supply mula sa pabrika ay nakakatulong na bawasan ang mga gastos sa pagbili habang pinapanatili ang maaasahang performance ng produkto at pare-parehong kalidad.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-9 wp-block-paragraph\"><strong>Maaasahang Kalidad ng Produkto<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ang bawat RCBO ay sumasailalim sa mahigpit na assembly inspection, tripping testing at electrical performance checks bago ipadala.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-995f960e wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-10 wp-block-paragraph\"><strong>Maramihang Konfigurasyon ng Produkto<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Available sa mga opsyong 2P, 3P, 3P+N at 4P, na may maramihang current rating, residual current sensitivities at mga uri ng proteksyon.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-11 wp-block-paragraph\"><strong>Matatag na Produksyon at Delivery<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ang mga standardized na proseso ng produksyon at maaasahang supply capacity ay tumutulong na matiyak ang pare-parehong kalidad ng produkto at on-time na delivery.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-palette-color-4-color has-text-color has-link-color wp-elements-12 wp-block-paragraph\"><strong>Propesyonal na Suporta sa Pagpili<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tinutulungan ng aming team ang mga customer na pumili ng angkop na mga modelo ng RCBO ayon sa mga electrical system, pangangailangan ng aplikasyon at target na merkado.<\/p>\n<\/div>\n<\/div>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h2 class=\"wp-block-heading has-palette-color-9-color has-text-color has-link-color wp-elements-13\" style=\"margin-top:var(--wp--preset--spacing--80);margin-bottom:var(--wp--preset--spacing--80)\"><strong>MGA MADALAS ITANONG TUNGKOL SA MGA RCBO<\/strong><\/h2>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><strong>Ano ang RCBO?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ang RCBO ay isang protective device na pinagsasama ang residual current, overload at short-circuit na proteksyon sa iisang unit.<\/p>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><strong><strong>Ano ang pagkakaiba ng RCBO at RCCB?<\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">An RCBO provides residual current, overload and short-circuit protection, while an RCCB mainly provides residual current protection.<\/p>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><strong><strong>What is the difference between 2P, 3P, 3P+N and 4P RCBOs?<\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A 2P RCBO is used for single-phase systems, a 3P RCBO is used for three-phase three-wire systems, and 3P+N or 4P RCBOs are used for three-phase four-wire systems.<\/p>\n<\/blockquote>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><strong><strong>What residual current rating should I choose?<\/strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A 30mA RCBO is commonly used for additional protection against electric shock, while 100mA or 300mA ratings may be used for equipment or fire protection.<\/p>\n<\/blockquote>\n\n\n\n<div class=\"wp-block-group alignfull has-palette-color-8-color has-palette-color-9-background-color has-text-color has-background has-link-color wp-elements-14 is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>NEED THE RIGHT RCBO FOR YOUR PROJECT?<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Share your required poles, rated current, residual current sensitivity and application. JUTRION will help you select the suitable RCBO solution.<\/p>\n<\/div>\n\n\n<div class='fluentform ff-default fluentform_wrapper_5  ff_guten_block ff_guten_block-5 ffs_default_wrap'><form data-form_id=\"5\" id=\"fluentform_5\" class=\"frm-fluent-form fluent_form_5 ff-el-form-top ff_form_instance_5_1 ff-form-loading ffs_default\" data-form_instance=\"ff_form_instance_5_1\" method=\"POST\" action=\"\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">Form ng Pagtatanong sa Produkto<\/legend>        <input type=\"hidden\" id=\"__fluent_protection_token_5\" class=\"fluent-form-token-field\" name=\"__fluent_protection_token_5\">\n        <input type='hidden' name='__fluent_form_embded_post_id' value='824' \/><input type=\"hidden\" id=\"_fluentform_5_fluentformnonce\" name=\"_fluentform_5_fluentformnonce\" value=\"f3eed64c26\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/tl\/wp-json\/wp\/v2\/pages\/824\" \/><div data-name=\"ff_cn_id_1\"  class='ff-t-container ff-column-container ff_columns_total_2'><div class='ff-t-cell ff-t-column-1' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_5_input_text' id='label_ff_5_input_text' aria-label=\"Pangalan\">Pangalan<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"input_text\" class=\"ff-el-form-control\" placeholder=\"Pangalan\" data-name=\"input_text\" id=\"ff_5_input_text\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><div class='ff-t-cell ff-t-column-2' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_5_input_text_1' id='label_ff_5_input_text_1' aria-label=\"Telepono \/ WhatsApp\">Telepono \/ WhatsApp<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"input_text_1\" class=\"ff-el-form-control\" placeholder=\"Telepono \/ WhatsApp\" data-name=\"input_text_1\" id=\"ff_5_input_text_1\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><\/div><div data-name=\"ff_cn_id_2\"  class='ff-t-container ff-column-container ff_columns_total_2'><div class='ff-t-cell ff-t-column-1' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_5_input_text_2' id='label_ff_5_input_text_2' aria-label=\"Email\">Email<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"input_text_2\" class=\"ff-el-form-control\" placeholder=\"Email\" data-name=\"input_text_2\" id=\"ff_5_input_text_2\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><div class='ff-t-cell ff-t-column-2' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_5_input_text_3' id='label_ff_5_input_text_3' aria-label=\"Kumpanya\">Kumpanya<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"input_text_3\" class=\"ff-el-form-control\" placeholder=\"Kumpanya\" data-name=\"input_text_3\" id=\"ff_5_input_text_3\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label asterisk-right\"><label for='ff_5_description' id='label_ff_5_description' aria-label=\"Ang Iyong Mensahe\">Ang Iyong Mensahe<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"false\" aria-labelledby=\"label_ff_5_description\" name=\"description\" id=\"ff_5_description\" class=\"ff-el-form-control\" rows=\"3\" cols=\"2\" data-name=\"description\" ><\/textarea><\/div><\/div><div class='ff-el-group'><div class='ff-el-input--content'><div class='ff-el-form-check ff-el-form-check-'><label class='ff-el-form-check-label' for='checkbox_9812da1c75c0d26af90608a2e0387f04'><input  type=\"checkbox\" name=\"checkbox[]\" data-name=\"checkbox\" class=\"ff-el-form-check-input ff-el-form-check-checkbox\" value=\"    Subscribe to receive our latest updates.\"  id='checkbox_9812da1c75c0d26af90608a2e0387f04' aria-label='Mag-subscribe upang matanggap ang aming mga pinakabagong update.' aria-invalid='false' aria-required=\"false\"> <span>    Mag-subscribe upang matanggap ang aming mga pinakabagong update.<\/span><\/label><\/div><\/div><\/div><div class='ff-el-group ff-text-center ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-sm ff_btn_style wpf_has_custom_css\"  aria-label=\"Ipadala ang Mensahe\">Ipadala ang Mensahe<\/button><\/div><\/fieldset><input type=\"hidden\" name=\"trp-form-language\" value=\"tl\"\/><\/form><div id='fluentform_5_errors' class='ff-errors-in-stack ff_form_instance_5_1 ff-form-loading_errors ff_form_instance_5_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_5_1 = {\"id\":\"5\",\"ajaxUrl\":\"https:\\\/\\\/jutrion.com\\\/wp-admin\\\/admin-ajax.php\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"asteriskPlacement\":\"asterisk-right\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_5_1\",\"form_id_selector\":\"fluentform_5\",\"rules\":{\"input_text\":{\"required\":{\"value\":true,\"message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global_message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global\":true}},\"input_text_1\":{\"required\":{\"value\":true,\"message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global_message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global\":true}},\"input_text_2\":{\"required\":{\"value\":true,\"message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global_message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global\":true}},\"input_text_3\":{\"required\":{\"value\":true,\"message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global_message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global\":true}},\"description\":{\"required\":{\"value\":false,\"message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global_message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global\":true}},\"checkbox\":{\"required\":{\"value\":false,\"message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global_message\":\"\\u8fd9\\u662f\\u5fc5\\u586b\\u680f\",\"global\":true}}},\"debounce_time\":300,\"file_upload_settings\":[]};\n                            <\/script>","protected":false},"excerpt":{"rendered":"<p>RCBO MANUFACTURER &amp; SUPPLIER JUTRION RCBOs combine residual current protection, overload protection and short-circuit protection in one compact device. Designed for residential, commercial and industrial distribution systems, they help improve electrical safety while reducing installation space and wiring complexity. EXPLORE OUR RCBO PRODUCT RANGE Choose from different pole configurations, rated currents, residual current sensitivities and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-824","page","type-page","status-publish","hentry"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/jutrion.com\/tl\/wp-json\/wp\/v2\/pages\/824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jutrion.com\/tl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jutrion.com\/tl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jutrion.com\/tl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jutrion.com\/tl\/wp-json\/wp\/v2\/comments?post=824"}],"version-history":[{"count":3,"href":"https:\/\/jutrion.com\/tl\/wp-json\/wp\/v2\/pages\/824\/revisions"}],"predecessor-version":[{"id":1691,"href":"https:\/\/jutrion.com\/tl\/wp-json\/wp\/v2\/pages\/824\/revisions\/1691"}],"wp:attachment":[{"href":"https:\/\/jutrion.com\/tl\/wp-json\/wp\/v2\/media?parent=824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}