2P & 4P RCCBS FOR RESIDENTIAL, COMMERCIAL AND INDUSTRIAL SYSTEMS

JUTRION RCCBs are designed to detect residual current leakage and disconnect faulty circuits quickly, helping reduce electric shock and electrical fire risks. Available in 2P and 4P configurations with Type AC and Type A options, they are suitable for residential, commercial and industrial distribution systems.

Superior Life & Fire Safety

Designed to rapidly detect low-level earth leakage currents and disconnect the circuit within milliseconds. It provides robust protection against lethal electric shocks and prevents electrical fires caused by insulation faults.

Flexible Type A & AC Options

Available in Type AC for standard AC sinusoidal leakage, and Type A to safely detect both AC and pulsating DC residual currents. This ensures comprehensive protection in modern systems filled with non-linear electronic loads.

Certified Global Standards

Manufactured in strict compliance with international IEC 60269 and IEC 61008-1 standards. Featuring CE certification and high-quality materials, JUTRION RCCBs deliver long-term reliability and stable operation in harsh environments.

JUTRION JRE7 2-Pole Residual Current Circuit Breaker (RCCB)

Key Features

  • Single-Phase Protection: Specially designed for single-phase systems (Phase + Neutral, 2P) to protect personnel from fatal electric shock and electrical fire hazards.
  • Dynamic Current Selection: Available in standard tripping sensitivities: 30mA (for life safety and direct touch protection) and 100mA/300mA (for system leakage and fire prevention).
  • Compact 2-Module Width: Designed with a standard width of 36mm (2 DIN modules) to maximize panel space efficiency in distribution boxes.
  • Type A & AC Compliance: Optional Type AC for standard AC leakage, and Type A to detect both AC and pulsating DC residual currents common in modern household electronics.

JUTRION JRE7 4-Pole Residual Current Circuit Breaker (RCCB)

Key Features

  • Three-Phase Power Protection: Engineered for three-phase four-wire (4P, 3P+N) industrial, commercial, and solar PV distribution networks.
  • Simultaneous Pole Disconnection: Features synchronous tripping of all 4 poles (including the neutral line) to ensure complete electrical isolation of the downstream system during earth faults.
  • High Interrupting Capacity: Delivers a robust conditional short-circuit current rating (Inc/IΔc) up to 6kA/10kA, ensuring stability under transient overload currents.
  • Heavy-Duty Industrial Application: Perfectly suited for protecting larger motor-driven loads, heavy HVAC equipment, and industrial workshop distribution panels.
ParameterJRE7 2P RCCBJRE7 4P RCCB
Poles2P4P
Electrical SystemSingle-phase, two-wireThree-phase, four-wire
Rated Voltage230V AC400V AC
Rated Current16–100A16–100A
Rated Residual Operating Current30mA / 100mA / 300mA30mA / 100mA / 300mA
Residual Current TypeType AC / Type AType AC / Type A
มาตรฐานIEC/EN 61008-1IEC/EN 61008-1

Choose the Correct Pole Configuration

For a single-phase two-wire system, choose a 2P RCCB to disconnect both the live and neutral conductors. For a three-phase four-wire system, choose a 4P RCCB to disconnect all three phase conductors and the neutral conductor.

Typical selection:

  • 2P RCCB: Residential buildings, apartments, shops and single-phase distribution boards
  • 4P RCCB: Commercial buildings, industrial panels and three-phase distribution systems

Select the Appropriate Rated Current

The rated current of the RCCB should be equal to or higher than the maximum normal operating current of the circuit. Common rated currents include 16A, 25A, 40A, 63A, 80A and 100A.

The rated current must also be coordinated with the upstream MCB, MCCB or fuse. The upstream protective device should prevent the RCCB from being damaged by overload or short-circuit current.

Example:
For a circuit protected by a 40A MCB, a 40A or 63A RCCB may be selected according to the system design and manufacturer requirements.

Choose the Correct Residual Current Sensitivity

The rated residual operating current determines how sensitive the RCCB is to leakage current. The correct value should be selected according to the required protection purpose.

  • 30mA: Commonly used for additional protection against electric shock in residential and final circuits
  • 100mA: Suitable for equipment protection or higher-level distribution circuits
  • 300mA: Commonly used to reduce electrical fire risks in main or distribution circuits

A lower residual current value provides more sensitive protection, but improper selection may increase nuisance tripping.

Choose Type AC or Type A

Type AC RCCBs detect sinusoidal alternating residual currents and are suitable for simple conventional AC loads. Type A RCCBs detect both sinusoidal AC residual currents and pulsating DC residual currents.

Type AC is commonly used for:

  • Electric heaters
  • Basic lighting circuits
  • Conventional resistive loads

Type A is more suitable for:

  • Washing machines
  • Air conditioners
  • Electronic power supplies
  • Frequency-controlled equipment
  • Household appliances containing electronic circuits

For modern residential and commercial systems with electronic equipment, Type A is generally a more comprehensive choice.

These three devices serve different protective functions in an electrical system. Here is a quick breakdown to help you choose:

  • MCB (Miniature Circuit Breaker): Protects equipment from Overload and Short Circuits. It does not protect against earth leakage or electric shock.
  • RCCB (Residual Current Circuit Breaker): Protects humans from Electric Shock and Earth Leakage. It does not protect against overloads or short circuits (it must be paired with an MCB).
  • RCBO (Residual Current Breaker with Overcurrent): An all-in-one device that combines the functions of both MCB and RCCB. It protects against Overload + Short Circuit + Earth Leakage.
อุปกรณ์Overload ProtectionShort Circuit ProtectionEarth Leakage ProtectionPrimary Protection Target
เอ็มซีบี (Miniature Circuit Breaker)YESYESNOCable & Equipment
อาร์ซีซีบี (Residual Current Circuit Breaker)NONOYESHuman Life & Fire Safety
อาร์ซีบีโอ (Residual Current Breaker with Overcurrent)YESYESYESComplete System & Human Life

Stable Residual Current Performance

JUTRION RCCBs are designed for accurate leakage detection and reliable circuit disconnection, helping reduce electric shock and electrical fire risks.

Wide Current and Pole Range

Available in 2P and 4P versions with rated currents from 16A to 100A, supporting both single-phase and three-phase distribution systems.

Cost-Effective Supply Solution

Optimized production and direct supply help provide reliable RCCB products at competitive prices for distributors and project buyers.

Market-Oriented OEM Customization

JUTRION supports customized branding, labels, packaging and product specifications to help customers build differentiated products for their target markets.

JUTRION RCCBs combine reliable residual current protection, stable tripping performance, flexible OEM/ODM customization and competitive factory pricing, providing dependable and cost-effective solutions for distributors, panel builders and electrical project customers.

What is an RCCB and how does it work?

An อาร์ซีซีบี (Residual Current Circuit Breaker) is a vital safety device designed to protect people from dangerous electrical shocks and prevent electrical fires. It constantly monitors the balance of current between the phase (live) and neutral wires. If an imbalance is detected—such as when current leaks to the earth because a person touches a live wire or due to damaged wiring—the RCCB trips and cuts off the power in milliseconds.

Does an RCCB require a neutral connection to operate safely?

Yes, for both 2P and 4P RCCBs, the neutral wire must be connected. The RCCB detects leakage currents by comparing the current flowing through the phase(s) and the neutral. Without a proper neutral connection, the internal sensing circuit cannot function correctly, and the test button will not work.

What is the difference between a 2-Pole (2P) and a 4-Pole (4P) RCCB?

A 2P RCCB is designed for single-phase circuits (Phase + Neutral) and is typically used in residential and light commercial settings. A 4P RCCB is designed for three-phase four-wire systems (Three Phases + Neutral) and is standard in industrial, commercial, and large solar PV installations.

Why choose JUTRION RCCBs for your electrical and solar projects?

JUTRION is a professional manufacturer with advanced production lines based in Wenzhou, Zhejiang, bringing over a decade of low-voltage industry expertise to every product. Our JRE7 series RCCBs are engineered and tested in strict compliance with international standards like IEC 61008-1. We offer reliable Type A and AC solutions, high-grade flame-retardant materials, and robust technical support to ensure safe, stable operation for global B2B and distribution projects.